Home

Panasonic WVPB5548 Manual

image

Contents

1. that the control data are activated normally on the board teo I Initially ON position is selected at the factory SW5 4 Confirm switches SW3 SW6 on the board are set to the following positions ee Note ann These switches are used only for factory test mim Always keep these switches in these positions in the n field ae Rg INSTALLATION Caution Before installing this board be sure to turn off ihe Power Rear Panel s Switch of the Matrix Switcher The following installation should be made by qualified ser vice personnel or system installers 1 Remove the screws from the rear panel s of the Matrix Switcher 2 Remove the rear panel s 3 Place the Data Board into the desired position in the rear of Matrix Switcher by sliding it inside the board guides Note Each slot is identical so the board can installed in any slot However it is recommended to install the board as shown below for an orderly installation Alarm Board Data Board 5 i al y d 4 S meron Video Input Board Video Outpu Board d Make sure to push in the Data Board until it is seated Tighten screws firmly 5 Secure the Data Board by tightening the two screws on the board 6 Close off open spaces on the rear of the Matrix Switcher by using WV Q63 Blank Panels Optional or supplied rear panels Refer to the instructions for WV Q63 Blank Panei e Note _____ SI Refer to the Oper
2. Instructions WV PB5548 Panasonic ie a aa eer 6P ee P peel peer rod Bene Pee a Caution r When handing this board hold oniy by hand board edges Otherwise components on tre board may be damaged by stalc electricity PREFACE The WV PBS546 Dala Board is used to tansmilreceive only control dala between the Matix Gwilcher and the camera site APPEARANCE r 5 alj a a i a sa i S E s w i di d 4 vi ar 0 54 E 71189 1 Data Connector TA TB RA AB GND 1 8 These connectors are used to iransmil receive control dala to from the camera siie Use data grade cable suitable lor RS 485 shielded twisted pairs Cable length may be extended up to 1 200 m 4 000 M TAD BOARD SETTING Before installing this board the following settings should be made by qualified service personnel or system installers 1 Set switches SW1 on the board to meet the data board number as shown in the following table Initially board number 1 is selected at the factory 2 Set switches SW100 SW150 SW200 SW250 SW300 SW350 SW400 SW450 on the board to choose the a communication lines as either Full Duplex FULL or Full 4 Lines Half Duplex HALF T Half 2 Lines Initially Full Duplex FULL positions are selected at the factory SW1i00 SW450 3 Set switch SW5 on the board to choose the LED indi cator as either ON or OFF mode The indicator dis plays
3. Number 5 Unit Number Camera In Number 6 Unit Number Camera In Number 7 Unit Number Camera In Number 8 Unit Number Note ___ _ _ ________ It is not available 2 Line Half Duplex connection in a Daisy Chain Caution m itis only available an alarm dala connected unit in a Daisy Chain Set the Mode Selection Switch on the one of Camera Controllers to the NORMAL position and the others are set to the ALARM OFF positions SPECIFICATIONS Data Input Output 1 8 RS 485 Full Duplex or Half Duplex selectable inside the switch 5 pin T A T B HLA R B GND X8 use with shield twisted pairs data cable Transmitting Speed Baud Rate 1200 19200 bps Max Cable Length 1 200 m 4 000 ft Max Number Boards 8 Address 1 8 Tolal 1 64 Data Input Output Dimensions 24 5 W x 265 H x 260 D mm 15 16 W x 10 7 16 H x 10 1 4 D Weight 400g 0 9 Ibs Weight and dimensions indicated are approximate Specifications are subject to change without notice 7 Panasonic Broadcast amp Television Systems Company Division of Matsushita Electric Corporation of America IMAGING SYSTEMS DIVISION Executive Office One Panasonic Way 3E 7 Secaucus Now Jorsoy 07094 Regional Offices Northeast 37 Hartz Way Secaucus NJ 07094 201 348 7303 Southeast 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30174 770 338 6835 Midwest 1707 North Rand
4. all Road Elgin IL 60123 708 468 5200 Southwest 4500 Amon Carter Blvd Fort Worth TX 76155 817 685 1117 Wesle 6550 Katalla Ave 17A 5 Cypress CA 90630 714 373 7265 MATSUSHITA ELECTRIC OF CANADA LIMITED 5770 Amblar Drive Mississauga Ontario LAW 273 Canada 905 624 5010 PANASONIC SALES COMPANY DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO INC San Gabriel Indusirial Park 65th Infantry Ave KM 9 5 Carolina Puerto Rico 00630 809 750 4300 NO396 0 YWV8QA4 IS6AN Printed in Japan N 19
5. ating Instructions of WJ SX550A for Jags eh further details B RNA C Data Board Tighten screws CONNECTIONS Connect the Data Board and the Camera Controler by specilied data cable Basically connect shown right Then the following settings should be made by using the Setup Menu s Camera Controller KI 49 Kx kt Bite Communication Communication Boara raar 1 Unit Number 1 Baud Rate 19200 Data Bit 8 Parity Check None Stop Bit 1 Xon Xoff Not Use Wait Time Off Delay Time off Alarm Data off Return 909099 O RAR NN G N t N e N N N rw Ke po pa M pt K M Ka Pii Pit F3 DEL FarPop Up R Direct Connection between the Data Board and Camera Controllers In this type of connection there is one contro cable directly SHETE each Data Gonnweler to the WV RM70 Camera Controller Refer to the connections and settings shown below 4 Line Full Duplex Connection SW100 150 200 250 TIO d 300 350 400 450 Intarnal Switch SW5 4 line FULL 4 fines TA mn lt mn lt rrer n n nante irr n r re SS SF r o a mn p em cer i ee ee foe ee ss nnn SE E a S ea Combination Camara oo SS ee E E v r lt n re ew ws lt i m Reciver P ee E el RR S 4 2 Line Half Duplex Connection x errr rean ct ee lt f SW100 150 200 250 300 350 400 450 HALF 2 lines 6 TA e n lt n er rrr an
6. n n co nenn lt ibi rrr lt rrn ees nn Se rara lt n T N B L Combination Camera Reciver ee SR aina SS nnn rk es Set the same Communication Parameters on the Setup Menus of the Matrix Switcher and Camera Controller Matrix Switcher Camera Controller Parameters WJ SX550A WV RM70 Baud Rate 19200 19200 es Pie wets or oeae ord es Ce es oe Ne ee ell Daisy Ol Unit Number Not use 5 E Indirect Connection between the Data Board and Camera Controllers Daisy Chain Type Wiring In this type of connection only one control cable directly connects between the Data Connector 1 and the Camera Controller 1 The rest of the Camera Controllers connect to Camera Controller 1 in a Daisy Chain of connection Refer to the connec tions and settings shown below 4 Line Full Duplex Connection SW100 150 200 250 P Internat Switch SW5 4 lines Gn berc 400 430 TA TB o uy o a errr er y E apn n Tle IIT KTT Ril wie Ta Ta a SLL gti ty et LELLI Combination Camera Sel the Matrix Switcher and the Camera Controllers up to 8 shown below Matrix Switcher Camera Controller Paramelers WJ SX550A WV RM70 F H Duplex Full Camera In Number 1 Unit Number Camera In Number 2 Unit Number Camera In Number 3 Unit Number Camera In Number 4 Unit Number Camera In