CHLORIDE SYSTEMS CCL/TCL Series High Capacity Steel Emergency Lighting Units

image

Contents

1. PHOTOMETRIC No 3 For DK suggested head for TCL HORIZONTAL LEFT 20 a 10 OSN 5N 1 A Fs Ly bt RIGHT 20 10 20 30 40 50 60 70 VERTICAL eT 19 CAN QA F Heo i gt BS 1 1 Down 20 o 10 20 30 40 so 60 70 SUGGESTED SPECIFICATION Furnish and install Chloride Systems emergency and the National Electrical Code NEC INSTALLATION AND OPERATION Unit shal ing a rated discharge of not more than 90 minutes CHARGER Product shall utilize a fully automati AC lockout emperatures up to 85 F 30 C ighting unit model EC as well as other applicable codes Upon utility power failure or brownout the unit shall automatical ion level for a minimum period of 90 minutes Upon restoration of utility power the charger shall res c voltage regulated two rate current limited solid s ull capacity without the need for periodic exercising or equalization The following features shall be s BATTERY The battery shall be a low maintenance free electrolyte wet cell lead calcium battery Th ELECTRONICS 120 277 VAC dual voltage input with surge protect ed solid state charging circuitry provides for a reliable charging system The charging system is furnished with low voltage disconnect AC lockout brownout protection AC indicator lamp and test switch The low voltage disconnect LVD featur
2. at andard Low voltage disconnect LVD brownout protection and e lead calcium battery shall provide trouble free operation in CHLORIDE 27 West Stag Park Service Road e Burgaw NC 28425 aaas FULA ops SYSTEMS Telephone 910 259 1000 e Facsimile 800 258 8803 a TERED Chloride Systems A DIVISION OF Gicenwr THomas GROUP LLC www chloridesys com WWW ALLDATASHEET COM Copyright Each Manufacturing Company All Datasheets cannot be modified without permission This datasheet has been download from www AllDataSheet com 100 Free DataSheet Search Site Free Download No Register Fast Search System www AllDataSheet com
3. CHLORIDE SYSTEMS A DIVISION OF Gicenvt THOMAS GROUP LLC GENERAL DESCRIPTION The CCL TCL Series provides functional emer gency lighting in a variety of wattages up to 450 watts High performance electronics and rugged 18 gauge steel construction ensure long term life Safety reliability ILLUMINATION Illumination is accomplished with up to three lamp heads mounted on the top of the unit The most popular lamp head for use with the CCL TCL Series is the D Series round sealed beam Par 36 tungsten lamp head The D head is available up to 30 watts DIMENSIONS CCL75 CCL100 CCL150 CCL225 TCL150 TCL200 TCL300 TCL450 ORDERING INFORMATION TYPE CATALOG NO CCL TCL Series High Capacity Steel Emergency Lighting Units 6 and 12 Volt 75 to 450 Watts Wet Cell Lead Calcium Battery HOUSING Constructed of 18 gauge steel with a tan epoxy powder coat finish Knockouts provided for mounting up to three lamp heads Bi color LED charge monitor indicator and a press to test switch are located on the front of the cabinet Choice of wedge base sealed beam tungsten or halogen lamp heads ELECTRONICS 120 277 VAC dual voltage input with surge protected solid state circuitry provides for a reliable charging system Charging system is complete with low voltage disconnect AC lockout brownout protection AC indicator lamp and test s
4. e free electrolyte wet cell lead calci um battery Standard sustained emergency operation is for 90 minutes with the illumination source providing full light output The suggested operating temperature range for lead calcium batteries is 65 F 19 C to 85 F 30 C and should provide a service life of 5 years PERFORMANCE Input power requirements 120 VAC 0 66 amps 80 watts 277 VAC 0 30 amps 80 watts CODE COMPLIANCE The CCL TCL Series meets or exceeds all performance standards as required by UL 924 NFPA 70 NFPA 101 NEC and OSHA OPERATION DC Suggested Watts to 87 Voltage Unit Lamp Head of Rated Voltage 1 hrs 2 hrs 4 hrs 8 hrs 6 CCL75 DL 75 56 28 5 15 CCL100 DL 100 75 38 20 CCL150 DL 150 112 5 57 30 CCL225 DL 225 169 85 5 45 12 TCL150 DK 150 112 5 57 30 TCL200 DK 200 150 96 34 TCL300 DK 300 225 114 60 TCL450 DK 450 337 5 171 90 The unit shall be constructed to meet Underwriter s Laboratories Inc Standard 924 ate charger HOUSING The unit housing shall be constructed of 18 gauge steel with a tan epoxy powder coat finish be easily field connected to a 120 or 277 VAC 60 hertz unswitched power source Installation must comply with the y transfer to battery power and maintain the required illumina ore the battery to full charge within UL 924 requirements follow The charging system shall maintain the battery
5. e will dis connect the battery prior to an unacceptable deep discharge but not before the required 90 minute emergency operation The AC lockout feature prevents battery drain prior to the initial energizing of utility power and allows the installer to complete all wiring and electrical connec tions without energizing the emergency circuit The brownout protection circuitry will automatically witch the unit into the emergency mode if the utility voltage sags below 20 of nominal n Battery charging circuitry is entirely solid state and utilizes a fully automatic voltage regulated charger Battery recharge time after full discharge is less than the required UL 924 standard Line sensitive electronics cause an instantaneous transfer to battery power if utility power is lost or a brownout condition is detected When line voltage is present and stabilized the transfer circuitry switches back to normal operation and begins recharging the battery The transfer circuitry can be tested via a momentary test switch located on the housing SELF DIAGNOSTICS The ACCU TEST Self Diagnostics option conducts automatic and manual tests and indicates real time status of the lamp battery and charger via LED indica tor lamps Automatic tests include Systems analysis every 10 seconds with actual load tests performed for a3 minute duration every 30 days A manual tests is available from 1 to 90 minutes BATTERY Low maintenanc
6. t Tungsten ACP1 120 VAC Power Switch 225 225 Watts DC 30 Watt Tungsten ACP2 277 VAC Power Switch AD ACCU TEST Self Diagnostics 12 Volt Includes standard voltmeter 12 Volt ADAL ACCU TEST with Alarm 150 150 Wa DNY 12 Watt Tungsten ADTD ACCU TEST with Time Delay 3 200 200 Wa DE 28 Watt Tungsten DCP DC Power Switch 300 300 Wa DK 25 Watt Tungsten EX Special Input Transformer Specify voltage and frequency 450 450 Wa DG 30 Watt Tungsten TD1 120 VAC Time Delay TTD2 277 VAC Time Delay 3 Suggested lamp heads listed V Voltmeter 2 Notes above Refer to the Accessories Section for W White Housing 1 Some option combinations may impact UL list ing consult factory for specifics 2 Not available wit AD ADAL or ADTD options 3 15 minute delay additional lamp head choices C1063R4 9 02 IH Specification Data for CCL TCL Series Steel Emergency Lighting Units HOUSING 18 gauge steel housing with a tan epoxy powder coat finish Knockouts provided for mounting up to three lamp heads The suggested lamp head is the D Series round sealed beam Par 36 tungsten To order lamp heads other than the suggested D head refer to Chloride Accessories Section LAMP HEAD PHOTOMETRICS For DL suggested head for CCL LEFT 30 L IN 1 20 5 3 Ke A 10 Sy a KK gt oO 10 20 30 40 50 60 70 80
7. witch Includes two fused output circuits Utilizes a fully automatic voltage regulated two rate cur rent limited solid state charger initially provides a high rate charge upon restoration of AC power and provides trickle charge to maintain batteries at full capacity once float voltage is attained Optional ACCU TEST Self Diagnostics includes an auto matic 3 minute discharge test every 30 days A manual test is available from 1 to 90 minutes WARRANTY Three year full electronics warranty One year full plus four year prorated battery warranty SHOWN CCL150DL2 BATTERY Low maintenance free electrolyte wet cell lead calcium battery Specific gravity disk indicators show relative state charge at a glance Operating temperature range of battery is 65 F 19 C to 85 F 30 C Battery supplies 90 minutes of emergency power CODE COMPLIANCE UL 924 listed NFPA 101 NEC BOCA and OSHA illumination standard PERFORMANCE Input power requirements 120 VAC 0 66 amps 80 watts 277 VAC 0 30 amps 80 watts cc l l SERIES DC LAMP OF FACTORY INSTALLED WATTAGE HEADS HEADS OPTIONS ACCESSORIES CCL 6 Volt 6 Volt 6 Volt 3 Three A Ammeter 2 TCL 12 Volt 75 75 Watts DY 8 Watt Tungsten 2 Two ACF1 120 VAC Fuse LMSHELF Mounting Shelf 300 450W 100 100 Watts DA 18 Watt Tungsten 1 One ACF2 277 VAC Fuse MXSHELF Mounting Shelf 72 200W 150 150 Watts DL 25 Wat