1. a 8008202190 b FLUKO Eumix R30 1 1 2 1 3 1 4 1 5 AF AR 1 6 1 JE MR AF HE HEAR AT 1 ae 7 GB70 85 M8X45 JA 2 Fs 2 M8 8 1 9 1 10 1 R30 Lab Type Homogenizer Operating Manual Description Driven by maintenance free no brush DC electric motor R30 Lab Type Homogenizer is suitable for mixing and homogenizing low medium and high viscosity liquids in laboratories Delicately designed with rotation speed precision engineered by microprocessor it is easy for operation with safety circuit overloading protection digital display and penetration type stator rotor generator Although the temperature of the unit will rise due to heat
2. 50 2000rpm 13 11 15 he 5 oe 2 40 C 3
3. FLUKO ee i BOA Pie iA 2 3 KMA Fy BY BY JI BY DES Ao FP Te EE o 4 ADA A A BR EN ATM KP ETE A a PE 5 6 1 ZAIRE HRA 2 RRA l ol FLUKO FLUKO
4. Stator rotor generator Framework Type Base Generator Up Down Movement Cap Operation Panel Rotation Speed Display Power Switch on off button Speed up Button Speed down Button Indicator AC DC Converter Installation Steps l Take the framework type base 7 out of package fix the iron pole 5 tightly to the base then screw on the nut Take supporting pole 2 fasten it tightly with M5 hexagonal screws on the back of the unit Set clamp 3 to the iron pole 5 at proper height screw tight one end of the clamp to fasten clamp 3 tightly to the iron pole 5 Raise the principle part of the unit 1 with supporting pole 2 set the supporting pole to clamp 3 screw tight another end of the clamp 3 to fasten the unit According to different operation situations turn loose the rotary clincher 4 with special tools to adjust generator 6 to a proper height If necessary remove the generator up down movement cap 8 to let the generator 6 penetrate through the principal part 1 reaching the needed height for convenient change of vessels Screw tight rotary clincher 4 to fasten the generator 6 tight Operation and Cautions ly Before starting check whether the rotation speed button is at the lowest rotation speed s
5. 2 7 5 2 M5 3 BAWI GO 3 3 5 E 2 1 3 3 4 KIF 6 Bim 8 6 1 KEERA 4 6 11 15 K C11 14 12 13 10
6. state electronic works safety standards for human and equipment Maintenance and Malfunction Analysis l Cleaning The part of generator contacting the material including dispersing head should be cleaned timely after each operation for next use Storing The unit should be kept away from moisture and direct sun light The unit should be operated and kept in place with ambient temperature no more than 40 C Malfunction Analysis If the electric motor cannot start first check whether the power supply plug and connection are proper If malfunction still exists please contact FLUKO After Sales Service in Shanghai Available Generator Dispersing head Types See Generator Illustration l Three Leaf Propeller Type Standard Type make the material flow from upper axis to lower axis with small cutting force It is for medium or high rotation speed operation Four Leaf Propeller Type make the material flow from upper axis to lower axis with topical cutting force It is for medium or high rotation speed operation Solution Type Produce material radial flow at both upper axis and lower axis to form strong turbulence and strong cutting force to ground the granules in the liquids It is for medium or high rotation speed operation Centrifuge Type The two leaves will expand with the increase of rotation speed it is suitable for vessels with narrow openings The mixing performance is similar to that of fo
7. R30 Soom SRA R30 CS AN 110 W 220 V 50 60 Hz X10 rpm 50 2000 rpm 60 Nem 0 5 10 mm H20 10 30 L 0 40 C 80 r He LE BX BO l
8. arising from its nonstop operation the large scale radiation surface and built in fan will rapidly cool the unit evenly The 2 meter long power supply wire is suitable for most cases with no need for extension The precisely designed hollow axis makes the generator freely insert and move up and down for easy change of mixing vessels Ine Caution Warnings marked with this symbol should be specially noticed As Caution Contents in the Operating Manual marked with this symbol should be specially noticed to avoid personal injury Technical Parameters Electric Motor Power 110 W Voltage Requirement 220 V 50 60 Hz Rotation Speed Display Digital Display X10 rpm Rotation Speed Range 50 2000 rpm Rotation Speed Adjustment Mode Stepless Adjustment Rotary Clincher Torsion 60 Nem Rotary Clinching Range 0 5 10 mm Working Capacity H20 10 30 L Working Environment Temperature 0 40 C Working Environment Relative Humidity 80 AN This unit is prohibited from operation in inflammable and explosion prone environment Install the unit on the base before operation Handheld operation is forbidden Installation Product Structure Illustration O oo nroa OD eo et gt e oF w bd DC No Brush Electric Homogenizer Principle Part Supporting Pole Clamp ERIA Rotary Clincher WAF Iron Pole
9. damage When deliver the unit for maintenance send it back to our After sales Service Toll free service hotline 800 820 2190 or take the unit to the local FLUKO dealer For units expiring the warranty period the user should undertake the cost
10. tatus and whether the power switch on off button 11 is off Plug the AC DC converter 15 into the power socket consistent with the power requirement of the unit put the pin shape plug into the jack on the back of the unit turn on the power switch on off button 11 and the indicator 14 will be lighted Observing the rotation speed appears on the rotary speed display 10 gradually adjust the speed up button 12 and speed down button 13 to the desired speed Rotation speed 50 2000rpm can be adjusted according to the viscosity of material Generally 4 lower viscosity materials require higher rotation speed After work is done adjust speed down button 13 to slow down the generator to the lowest rotation speed status Turn off power switch 11 and unplug the power supply of AC DC converter Fluctuations of working voltage of the unit should never exceed 5 It is recommended that a voltage regulator be installed if fluctuations are too big With electronic components installed within the unit please handle carefully and keep clean IME The unit is strictly prohibited from empty running as this may cause damage A Do not operate before the generator is put inside the vessel to avoid personal injury to the operator To ensure safety it is recommended that operator wear safety helmet to avoid hair being entangled Please establish and follow strictly safety operation procedures in accordance with relevant
11. ur leaf propeller type It is for medium or high rotation speed operation Fan Blade Type Produce tangential flow and small turbulence with good heat exchange performance It is used for gentle mixing cases It is for medium or low rotation speed operation Anchor Type Produce tangential flow with high cutting rate at edges making it hard for material deposits on the inner wall of the vessel It is for low rotation speed operation Used in polymer reactions and the dispersing of minerals in liquids it is an ideal mixing components for medium and high viscosity liquids 4 Generator Figure Three Leaf Wind Stick Type Standard Type Four Leaf Wind Stick Type Solution Type Centrifuge Type Jj Freak Fan Blade Type Anchor Type Dore oN After Sales Service l FLUKO Company provides free maintenance service during the warranty period one year since the purchasing day However if it is proven that the malfunction is caused by the improper operation or intended damage on the buyer s part FLUKO Company will be free of any obligations arising from it Warranty card should be submitted while delivering the unit for maintenance Disassemble the unit without noticing FLUKO Company or Dismantle parts not to be dismantled as listed in the Operating Manual will be regarded as intended