Home

Panasonic WJ-HDE500/WJ-HDE505 Manual

image

Contents

1. OFF ts used for other than the end unit E Rack Mounting 1 Remove the four rubber feet by removing four screws from ihe bottom of the unit 2 Fix the Rack Mounting Brackets supplied on both sides the unit with 4 screws M3X10 supplied 3 Install the unit in the rack securing it with four screws not supplied Cautions e Keep the temperature in the rack below 45 C 113 F e Do not block the ventilation opening or slots on the cover to prevent the appliance trom overheating SCSI 1D O 0 TERMINATION De OFF Remove 4 screws M3X10 Supplied Dl iS i ets Rack Mounting Bracket Supplied M5X12 Not supplied E Troubleshooting No power is supplied Power cord connection is insufficient sea Plog he Coreg ino AG eater ad AG CE 7 Thema ror OPERATE nat Set termination properly E Specifications Required Power AC 120 V 60 Hz Power Consumption 55 W inclusive of 4 HDD units if installed Interface SCSI 2 FAST SCS Half pitch 50 pin D Sub Operating Temperature 5 to 45 C 41 F to 113 F Dimensions 420 mm W x 88 mm H x 350 mm D rubber feet exclusive 16 9 16 x 3 7 16 x 13 13 16 Weight WJ HDESO0 7 3 kg 16 Ibs WJ HDESOS 8 0 kg 77 6 Ibs Weight and dimensions indicated are approximate Specifications are subject to change without notice E Accessory POWER Ol 6 haan ened E se eames aI 1pc no Ore EG ho gt Rani re eee A n
2. designed to provide rea sonable protection against harmful intarterance when the equipment is operated in a commercial environment This equipment generates uses and can radiata radio traquency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Caution To assure continued compliance example use only shielded interface cables when connecting to com puter or peripheral devices Any changes or modifications not expressly approved by the party responsible for campli ance could void the user s authority to operate this equip ment cc The serial number of this product may be found on the bot tom of the unit You should note the serial number of this unit in the space provided and retain this book as a permanant record of your purchase to aid identification in the event of theft Model No Serial Neo E General The WJ HDE500 and WJ HDES505 are the Extension Units for installation with the digital disk recorder WJ HD500 to extend its disk capacity Extension is available by connecting a maximum of 6 extension units in the SCSI chain while an extension unit can contain up to four HDDs The WJ HDE505 is used to assure driving capability for the SCS chain w
3. of operation Do not block the ventilation opening or slots on the cover To prevent the appliance from overheating place it at least 5 cm 2 inches away from the wall E Appearance Front View Rear View Extension Una WI HOE o gt AN a pom OO Ge SSD S 6 U gt 4 O WO WM 0 lt FRONT VIEW gt Operate Indicator OPERATE Lights in green while the power is supplied to the unit Lignts in orange when a thermal error is detect ed inside the unit HDD Access Lamps HDD 1 HDD 2 HDD 3 HDD 4 Lights while the HDD is accessed Do not turn off the POWER switch while any of the access lamps is lit Front Lids Four HDD openings are prepared inside the exten sion unit Remove the tid to install the HOO Replace the lid after installation lt REAR VIEW gt SCS In connector EXT IN Connect the WJ HD500 or other Extension Unit with a SCSI cable SCSI Out connector EXT OUT Connect another Extension Unit with a SCSI cable SCSI ID Switch SCSI ID Press the upper or tower selector with a small head ed screw driver to select the desired SCSI ID in the chain Termination Switch TERMINATE ON OFF Set this switch to ON when the extension unit is located at the end of SCSI chain Set this to OFF unless the unit is located at the chain end Terminal Board THERMAL ERROR OUT G A thermal error signal is supplied and OPERATE LED lights i
4. HDES505 if further extension unit is connect ed Use a WJ HDES500 if the 3rd unit is locat ed at the end of SCSI chain Extesion Unit 3 WJ HDE500 or WJ HDE 505 SCSIID 3 Ba ee Boa 5 noe m Extesion Unit 6 WJ HD500 SCSI ID 0 oe SCSI Cable Extension is available up to 6 units i i nd he pect Use a WJ HDES05 for the 3rd unit position if further unit is extended Use a WJ HDE500 if the 3rd position is the end of the SCSI chain Error Connection Connect each error output with CONTROL port on the WJ HDD500 rear panel as shown The WJ HD500 will display a warn ing of the thermal error on the monitor WJ HD500 CONTROL Port 13 1211109 87 t Extension Unit 1 G Terminal board on Extension Unit 2 the Extension Unit Somer A G Extension Unit 3 O onide Extension Unit 4 rror Ou poi z Etension Unit 5 To CONTROL port on ae e i the Digital Disk Recorder G WJ HD500 Extension Unit 6 aa Switch Settings 1 Set the MODE switch 2 on the rear of the WJ HD500 to ON when connecting with the extension unit 2 Set the SCSI ID for each unit by pressing the and buttons on ihe rear of the extension unit 0 to 5 Are applicable to the extension unit Note SCSI ID 6 and 7 are reserved for WJ HD500 Digital Disk Recorder 3 Set the termination switch to ON or OFF ON Is applied to the extension unit located at the end of the SCSI chain
5. Instructions Before attempiing to connec or operate this product pease read Teese instructors carefully and save this manual tor future Uee Panasonic Extension Units WJ HDE500 Model No WU H DE505 WARNING o reduce the risk of fire or electric shack do not expose this product to rain or moisture All work related to the installation of this product should be made by qualified service personne or system installers CAUTION Read the label on th bottom of the unit for identification of this product and the power ratings CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN GAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL SA 1965 SA 1966 The lightning flash with arrowhead sym bol within an equilateral triangle is intended to alert the user to the pres ence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilat eral tnangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appli ance For U S A NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FOC Aules These limits are
6. Prepare an HOD unit HDD Fixing Bracket 5 Mount the HDD on the fixing bracket then fasten them together with 4 screws 4 6 Set the unit address with jumper connector on the HDD as shown Note For further details refer to the instructions included in the HDD unit J 7 Place the HDD into the appropriate opening then fix it with 2 screws 8 Plug the 2 connector harness to the installed HDD as shown 9 Repeat above steps for HDD 2 through 4 10 Replace the front lid as before HDD 2 amp 4 SLAVE HDD 1 amp 3 MASTER gt O o o o O oO Jumper Position ooo o 0 0 Jumper Position Jumper Connector a E Connection amp Switch Setting ee Digital Disk Recorder SCSI Connection were SCS ID 6 amp 7 The Digital Disk Recorder WJ HD500 controls the extension units through the SCSI chain B SECU SE STSSS oO 1 Connect between the EXT STORAGE portion EAOn n A ees the WJ HD500 and the EXT IN port on the 1st SCSIID 5 SCSI ID 2 extension unit with the supplied SCS cable gt fT a e cable Repeat connections in the same manner tor the foltowing extension units 2 Connect between the EXT OUT port on the 1st extension unit and the EXT IN port on the r Ez 2nd extension unit with the supplied SCSI 0 Extesion Unit 2 9 Extesion Unit 5 i WJ HDE500 nH wn WJ HD500 O 9 N ies 3 The 3rd extension unit must be a Wd
7. hen more than 3 extension units are connected E Precautions Do not operate the appliance beyond its specified temperature humidity or power source ratings Do not use the appliance in an extreme environment where high temperature or high humidity exists Use the appliance at temperatures within 5 C to 45 C 41 F to 113 F and a humidity below 90 The input power source for this appliance is 120 V AC 60 Hz Avoid shock and vibration Shock or vibration may damage the HDD while operating or not operating Do not move the HDD for 30 seconds right after turning off the power Pay attention to static electricity Put your hand on a metallic surface to discharge Static electricity before installation Do not touch components mounted on the HDD directly with hand Hold only both sides of the HDD when installing Avoid condensation on the surface of the HDD Wait until the dew evaporates if any of the following cases takes place The appliance is moved to a place significantly def erent in temperature or humidity The appliance is moved out from the air conditioned room The appliance is placed in an extremely humid place The appliance is placed in a room where heater has just been turned on e Consumable parts Contact your dealer for the replacement when the time comes Built in hard disk needs replacement after around 30 000 hours of operation Cooling fan also needs replacement after around 30 000 hours
8. n orange when the inside temperature exceeds or falls below the limit Connect these ter minals with the WJ HD500 INC No connection Cooling Fan 0 AC Inlet AC IN Connect the supplied power cord G Power Switch POWER Turn on this switch peripherals first then the power of the WJ HD500 Confirm all HDD access lamps go out before turning off this switch Switch off the power of the WJ HD500 first then turn off this switch peripherals 2 Signal GND Terminal SIGNAL GND Connect this terminal with other equipment s SIG NAL GND to avoid possible grounding loop and noise if required E Mounting HDDs A maximum of 4 HDD units locally procured can be mounted on one extension unit This page describes how to install 1 HDD Repeat the same procedures as 1 for 2 through 4 HDD HDD Positions Inside The Lid Tne HDD units should be installed into the proper open ings in order as shown Never skip or reverse the posi tion order of the HDD units 1 Remove the front lid 1 1 Loosen the front lid fixing screw 1 2 Slide the lid to the right and remove it Front Lid 2 Remove the HDD bracket 1 2 1 Loosen 2 screws as shown 2 2 Pull the bracket 1 out of the opening 3 Disassemble the bracket 1 Separate it into the fixing bracket and dummy bracket by loosening 4 screws Keep the removed fixing bracket and 4 screws so that Dumm they are to be used later abi Bracket 4
9. y a Eee a 1 pe Rack Mounting Brae Glwisioiicicskadecacs seasons cecpbocsedasecorsestivanes 2 pcs _ Bracket Fixing SOI OW se fiowessuiscvcaielatestanundivansoninetgepnoreseennedent 4 pcs Panasonic Security and Digital Imaging Systems Company Panasonic Canada Inc A Division of Matsushita Electric Corporation of America 5770 Ambler Drive Mississauga Executive Office One Panasonic Way 3E 7 Secaucus New Jersey 07094 Ontario L4W 2T3 Canada 905 624 5010 Regional Offices Northeast One Panasonic Way Secaucus NJ 07094 201 348 7303 Panasonic Sales Company _ Southem 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30024 770 338 6838 Division of Matsushita Electric of Puerto Rico Inc Midwest 1707 North Randalt Road Elgin IL 60123 847 468 5211 Ave 65 de infanteria Km 9 5 Westem 6550 Katella Ave Cypress CA 90630 714 373 7840 San Gabriel Industrial Park Carolina Puerto Rico 00985 809 750 4300 NMO0900 1100 V8QA5621BN Printed in Japan 2000 Matsushita Communication ncustrial Co Ltd All rights reserved N 19