1. While the Clock is in Time Mode the pool equipment can be manually activated by simply pushing the appropriate Equipment Button FILTER CLNR SPA or AUX1 This will temporarily override any preset program which may be in effect 2 PROGRAM MODE In order to preselect daily filtration cycles pool cleaning spa use and an auxiliary function such as spa light the Clock must be switched to Program Mode To achieve this push PROGRAM Button once Whenever Clock is in Program Mode PROG will appear on the right of the Display After programming is complete the Clock will automatically return to Time Mode SETTING THE CLOCK f the Clock is not already in Time Mode push PROGRAM Button until TIME appears on the right of the Display This indicates that the Clock is in Time Mode TIME CONTROL 5 PROGRAM I naini O Push the HOURS and MINUTES Buttons until the correct time of day is displayed Pay special attention to the AM PM indicator Mt ig PM nc ewes n FOO PROGRAMMING DAILY OPERATING CYCLES Programming the daily operating cycles of your pool equipment is a set and forget procedure which is normally implemented by your Pool Builder at the completion of the installation Most systems only require that you program the filtration and in some cases the cleaning cycles of the pool However it is possible to program the spa if you plan to use it at the same time every day and also AUX1 if you are using th
2. and FLOW CONTROL Switch to the SPA position Unplug cables from Valve Operators At the LX 10 Service Center turn FLOW CONTROL Switch to the POOL position and SYSTEM CONTROL Switch to the AUTO position At the electrical supply panel turn off the pool cleaner circuit breaker At the CP 2000 Controller turn POOL Heat Select Switch to the OFF position If your control system incorporates solar ensure that the panels are completely drained and at the LX 10 Service Center turn SOLAR CONTROL Switch to the OFF position If your system is equipped with Recirculating Freeze Sensors it may not be necessary to drain the pool However it is recommended that all Freeze Sensors be tested by an authorized Serviceperson before the onset of the winter season TEMPERATURE CONTROL Separate electronic controls are provided for POOL and SPA heating Each control incorporates the following THERMOSTAT Dial Used to preset your desired water temperature As long as the Heat Select Switch is not in the OFF position the water will heat up to the preset temperature whenever the filter pump is running Heat Select Switch It is possible to heat your spa and swimming pool using solar energy conventional heat or a combination of both However no heating will take place unless the filter pump is running SOLAR Position Allows heating with solar only S PREF Position Allows preferential heating with solar but automatically
3. 2000 POOL SPA CONTROL SYSTEM The CP 2000 is an electronic control system which is designed to coordinate and operate all of the equipment associated with your swimming pool and spa The system is comprised of three principal components the CP 2000 CONTROLLER two VALVE OPERATORS and the LX 10 SERVICE CENTER The Controller automatically controls and monitors the timing of all your pool and spa equipment and the temperature of your pool and spa the Valve Operators switch the filter and heater from pool to spa and activate the solar system if applicable and the Service Center provides easy maintenance for your Pool Serviceperson Additionally the CP 2000 incorporates important safety features which protect your pool equipment from accidental damage See Page 2 Your system may also include additional Remote Controls and special options which further add to the convenience safety and economy of operating your pool equipment Before using this electrical equipment obtain a copy of the Installation Instructions and a completed EQUIPMENT CHECKLIST from your Pool Builder Additionally a 6 minute video VHS format is provided as an aid for the first time user of the Compool CP 2000 Control System Compool Corporation Compool Mountain View computerized pool systems California 94043 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS Basic safety precautions should always be followed when operating and
4. Overrides AUX 2 Equipment Button at CP 2000 4 AUX3 Activates auxiliary equipment such as air blower Overrides AUX 3 Equipment Button at CP 2000 5 AUX 4 Activates auxiliary equipment such as jet pump AUX 4 cannot be controlled from the CP 2000 If an optional Expansion Module model MOD BOOST has been installed itis additionally possible to activate the following features from the Spa side Remote Control 6 HEAT BOOST Overrides the spa thermostat and activates the spa heater for a five minute period If the filter pump is not running this button will be inactive 7 AUX5 Activates auxiliary equipment such as landscape lights 8 AUX6 Activates auxiliary equipment such as a fountain This feature is only possible if a pool cleaner valve is used and there is no two speed filter pump or electric heater being used A status light is located in the center of each Spa side Remote Control If an optional Status Light Module model MOD SS4 has been installed this light will indicate either 1 whenever the heater is enabled or 2 whenever the spa is being circulated INDOOR REMOTE Your system may include a 3 button or 6 button Indoor Remote Control which enables you to operate the spa and auxiliary equipment from another remote location inside your house These Indoor Remotes include a status light for each piece of equipment The Indoor Remote Controls are also available with a Digital Temperature Display which wil
5. servicing this electrical equipment WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times SAVE THESE INSTRUCTIONS SAFETY FEATURES HEATER PROTECTION A built in electronic delay circuit automatically runs the filter pump for an additional four minutes whenever the system is turned off This feature enables the heater to cool down so that the heat exchanger and plumbing are not damaged from overheating For testing and servicing purposes it is possible to override this delay circuit by pushing the DELAY CANCEL Button at the CP 2000 Controller POOL CLEANER PROTECTION If your system incorporates an automatic pool cleaner it will have been plumbed in conjunction with the filter pump so that it must have water circulation in order to operate The CP 2000 incorporates the following protection features against possible pump damage if there is no water circulation 1 Your pool cleaner will automatically be switched off whenever water is being circulated to the Spa 2 The filter pump will automatically be activated whenever the pool cleaner is running even if the filter pump has not been switched on 3 Additionally whenever the pool cleaner is turned on a built in electronic delay circuit will prevent it from running until 4 minutes have passed This protects the pump from possible damage caused by air which may have entered the plumbing since
6. the system was last used For testing and servicing purposes it is possible to override this delay circuit by pushing the DELAY CANCEL Button at the CP 2000 Controller 4 lf your system incorporates solar the pool cleaner will automatically be disabled for a period of 4 minutes whenever the solar system turns on This protects the pool cleaner from possible damage caused by residual air within the solar panels BATTERY BACK UP In case of a power failure a long life battery automatically maintains the program and clock functions of your Control System This safeguards against the equipment operating erratically once power has been restored and also eliminates the need to reprogram whenever there is a power failure 2 MAINTENANCE REPLACING THE BACK UP BATTERY There is a small 3 volt lithium battery located on the backside of the CP 2000 Controller In the absence of power this battery will keep the clock running and retain the programming in memory for approximately 48 hours While power is connected to the system the battery will not be drained However it is not rechargeable To replace the battery 1 2 3 Remove the four mounting screws from CP 2000 Controller 2 at each side Carefully fold Controller out still connected to cable Pry out old battery from battery clip and replace it with a new one Pay special attention to the polarity sign The Replacement battery is available directly from Com
7. E PROG in Program Mode minutes are advanced in ten minute increments G fad Baal Push FILTER Equipment Button aa ON should appear directly above FILTER Orr er Pee Button FILTER CLNR SPA AUXI lf ON is displayed above any of the other FASA EQUIPMENT Buttons push appropriate Button OQ once and OFF will appear You have now completed the first program step in order to lock in the program simply push the PROGRAM Button once PROG 2 will now appear on the right of the Display This indicates that the second program step is ready to be entered Enter the second program time 10 00 am by TIME CONTROL pushing the HOURS and MINUTES Buttons PROGRAM Push CLNR Equipment Button l ON should appear directly above CLNR TEE amp HOURS ae Button ae In our example at 10 00 am the filter pump MINUTES should still be running However it will not be FILTER CLER SPA AUXI necessary to push the FILTER Equipment O paray Button cs the built in dpe circuit WO a amp uri will automatically activate the filter pump whenever the pool cleaner is on Make sure that OFF is still displayed above SPA and AUX1 Equipment Buttons Push PROGRAM Button to lock in the program PROG 3 will now appear on the right of the Display This indicates that the third program step is ready to be entered Enter the third program time 12 00 pm by TIME CONTROL pushing the HOURS and MINUTES Butt
8. ONE YEAR LIMITED WARRANTY Compoo Corporation warrants to the purchaser of this electronic control system for the period of one year from the date of original purchase for use that any defective product proved to be caused by faulty workmanship or faulty material will be repaired or replaced at Compool s option for no charge providing the product is returned to Compoo with all transportation charges prepaid This warranty covers the CP 2000 Controller LX 10 Service Center Valve Operators and optional Remote Controls including all components and parts It does not include Sensors batteries or labor for calibration It extends to the first retail purchaser and any subsequent owners of the system This limited warranty applies only to controls which have been installed and maintained in strict accordance with installation and operating instructions provided by Compool Corporation using installation hardware supplied and or recommended in writing by Compool and to controls which have been connected to the correct supply voltage This limited warranty does not apply to any controls which have been repaired or altered by anyone other than Compool or a person authorized by it or which have been subject to misuse neglect or accident or which have been damaged by wind rain lightning freezing or other cause thing person or act of God or which have been subject to damage in transit during installation or by someone other than Compool Co
9. T OPERATE At the CP 2000 make sure that POOL and SPA Heat Select Switches are in the HEATER or S PREF position and that THERMOSTAT Dials are set correctly 2 Check the WATER TEMPERATURE Display Three dashes or an unreasonably high temperature indicates that there is a malfunction at the Water Sensor 3 Check that filter pump is running 4 Check the filter pressure If filter is clogged the heater may not be getting sufficient water flow 5 Inside the heater check pilot light and heater controls Heater must be turned on and its own thermostat must be turned all the way up 6 Heater may require servicing SOLAR DOES NOT OPERATE Note Ambient air temperature must be approximately 5 degrees warmer than the water temperature before the solar system is activated 1 Check that filter pump is running 2 At the CP 2000 make sure that POOL and SPA Heat Select Switches are in the SOLAR or S PREF position and that THERMOSTAT Dials are set correctly 3 Check that cable has not been unplugged from Solar Valve Operator 4 At the LX 10 turn SOLAR CONTROL Switch to the ON position and check to see if Solar Valve rotates Return Switch to AUTO position at completion of test SPA DOES NOT HEAT UP TO 104 F 1 Inside the heater check that thermostat is turned all the way up 2 High limit control on heater may need adjusting Refer to a qualified Service Company 3 if HEATER Status Light at the CP 2000 turn
10. a light The PROGRAM HOURS and MINUTES Buttons are used for setting the Clock and for programming the daily operation of the pool equipment See Page 8 The DELAY CANCEL Button is used to override the Filter Pump Off Delay or Pool Cleaner On Delay circuits for testing and servicing purposes only REMOTE CONTROL Additional remote circuits may have been added to your system to contro more auxiliary equipment such as a pool light air blower jet pump waterfall etc Note These functions are not controlled by the Programmable Clock STATUS DISPLAY Status Lights are provided for the various pieces of equipment controlled by the CP 2000 The presence of a light indicates that the equipment has been activated The absence of a light indicates that the equipment is turned off REMOTE CONTROLS SPA SIDE REMOTE One or more 4 button waterproof Remote Controls called SUPERSWITCH may be located at your spa This will enable you to override the CP 2000 Controller and activate your spa equipment from the convenience of the spa It is possible to control the following equipment from the Spa side Remote Control 1 SPA Activates the filter pump rotates vaives to spa circulation and enables the spa to be heated Overrides SPA Equipment Button at CP 2000 2 AUX 1 Activates auxiliary equipment such as spa light Overrides AUX 1 Equipment Button at CP 2000 3 AUX 2 Activates auxiliary equipment such as pool light
11. am In this instance it is possible to enter a once only program step which will occur within the following 24 hour period without having to reprogram the daily equipment sequence The once only program will automatically be canceled once the Clock reaches its next program step Push PROGRAM Button to put the Clock into TIME CONTROL Program Mode PROG will appear on the right of the Display Continue to push PROGRAM Button until a flashing ONCE appears Enter the time that you wish to activate the spa 11 00 pm in our example by pushing HOURS and MINUTES Buttons Push SPA Equipment Button i ON will appear directiy above the SPA and FILTER Buttons Push PROGRAM Button to lock in program Remember to manually turn off the spa after use otherwise it may run all night until the Clock reaches its next program step J anel mm C oooo EIGHT PROGRAM STEPS lf the standard six program steps are insufficient for your particular programming requirements it is possible to modify the Clock so that eight program steps may be entered Consult the Installation Manual for details TIME CONTROL OFF OFF OFF _ _ OFF PUTER CAMA SPA AWII OOO TROUBLE SHOOTING GENERAL 1 Check all circuit breakers at the electrical supply panel 2 At the LX 10 Service Center ensure that SYSTEM CONTROL Switch is in the AUTO position all MANUAL CONTROL Switches are in the OFF position FLOW CONTROL Switch is in the POOL p
12. e Display Continue to push PROGRAM Button until a flashing TIMER appears Push the MINUTES Button once 0 10 will appear on the Display Push appropriate Equipment Button AUX 1 in our example ON will appear directly above Equipment Button Push PROGRAM Button to lock in the program TIME CONTROL PROGRAM Q Pi I o ya RERIT HOURS te 2 OFF OFF OFF I amr O PAYER CLHA SPA AUKI 4 anak O ADDITIONAL AUXILIARY CONTROL if your Control System does not utilize a poot cleaner your Pool Builder may have overridden the built in Poo Cleaner Protection Circuits so that the CLNR Equipment Button can be used to activate an additional auxiliary function such as landscape lighting in this instance the equipment will turn on TIME CONTROL immediately no 4 minute ON delay and the filter pump will not be simultaneously activated PUTER CLIR SPA AUKI PROGRAM LOCK To safeguard against someone accidentally pushing the PROGRAM Button and inadvertently tampering with your daily program your Pool Builder may have included a Program Lock feature In this instance you will need to push the PROGRAM Button quickly twice in order to put the Clock into Program Mode SERVICE CENTER Located in close proximity to your poo and spa equipment the LX 10 SERVICE CENTER provides your Pool Serviceperson with manual contro of the system without having to gain access to the CP 2000 Controller CAUTION To
13. ep by step and the appropriate STATUS DISPLAY Lights will turn ON and OFF as each program step is activated When the review is complete the Ciock will automatically return to the correct time of day and will also return all equipment to its previous status DELAY CANCEL For testing and trouble shooting purposes occasionally it may be necessary to temporarily override the built in Filter Pump Off Delay or Pool Cleaner On Delay circuits To do this simply push the DELAY CANCEL Button The Delay wilt automatically reoccur the next time the filter pump turns off or the pool cleaner turns on CUSTOM CLOCK OPTIONS The standard CP 2000 Controller is provided with the appropriate equipment interlock and safety delays and enables you to enter a total of six program steps Your Pool Builder may however have incorporated one or more of the following custom features COUNTDOWN TIMER This feature enables you to preset a 10 minute operating cycle for any piece of equipment FILTER CLNR SPA or AUX1 Whenever that equipment is activated it will run for 10 minutes and then it will automatically switch off To better understand this feature let us look at a typical application For example we are using the AUX1 circuit to activate a spa jet pump and we would like the jets to run for a period of 10 minutes whenever they are activated Push PROGRAM Button to put Clock irito Program Mode PROG will appear on the right of th
14. h must be in the SERVICE position The POOL and SPA positions wilt automatically rotate the motorized valves to the appropriate ON a water circulation MPE ae The FILL and DRAIN positions are used when cleaning the spa See page 16 Note It is advisable to return FLOW CONTROL Switch to POOL position after use SOLAR CONTROL This Switch should be kept in the AUTO position for normal system operation The OFF and ON positions provide manual override of your solar system and should be used for servicing and testing purposes only OUTDOOR REMOTES This Switch should be kept in the ON position for normal system operation The OFF position will disable any optional Remote Controls which may have been added to your system This feature is particularly convenient if your system includes a Spa side Remote Control and you wish to prevent the unauthorized use of your spa while you are away from home s PROGRAMMING INSTRUCTIONS The CP 2000 Controller houses a 24 hour Clock with a digital display which can be used to program daily pool filtration cleaning and other auxiliary functions such as pool and spa lights It can also be used to program and preheat your spa so that it is ready for use when you arrive home The Clock has two operating modes 1 TIME MODE In Time Mode normal operation the Clock will display the actual time of day and TIME will appear on the right of the Display
15. he jet action 4 Whenever the heater is on This feature will conserve energy by bringing your pool and spa up to the desired temperature more quickly 5 Whenever your solar system is operating This provides high flow rate through your solar panels which ensures the most efficient usage of the available solar energy SPA WATERFALL CONTROL if your spa water level is elevated above that of the pool your Pool Builder may have included a Spa Waterfall Control modet RLY WTREFL With this feature you can circulate the poo water back to the spa creating an overflow waterfall effect from the spa to the pool This effect will cease during spa circulation Depending upon which circuit has been used to connect the Spa Waterfall Control either the AUX1 AUX2 or AUX3 Button will activate this feature FREEZE PROTECTION Recirculating Freeze Sensors model FPS C may have been added to your system These Sensors protect the plumbing and equipment from possible freeze damage by running the filter pump whenever the temperature falls to approximately 41 F Similarly Auxiliary Pump Freeze Sensors model FPS AUX may have been added to activate auxiliary equipment such as a fountain or jet pump during freezing conditions CAUTION Freeze Sensors will not provide circulation of water through your solar panels Solar freeze protection must be accomplished by draining the panels See below SOLAR PANEL DRAINDOWN If your Control system i
16. is circuit to activate lights or some other equipment which you wish to operate at the same times every day It is possible to preset six program steps during a 24 hour period Each of the six steps can be used for turning equipment ON or OFF More than one piece of equipment can be turned ON or OFF at each program step However to turn the same piece of equipment ON and OFF requires two program steps Once the programming is complete the pool and spa equipment will operate at the same times every day Before commencing programming it is advisable to determine at what time you would like the equipment to turn on and for how long you would like each piece of equipment to run To better understand the programming sequence let s follow a sample program step by step For demonstration purposes our example assumes that we would like to activate all four pieces of equipment on a daily basis as follows Filter the pool from 7 00 am until 12 00 pm Turn the pool cleaner on from 10 00 am until 12 00 pm Turn the spa on from 6 30 pm until 8 00 pm Turn auxiliary 1 spa light on from 6 30 pm to 10 00 pm To begin programming push PROGRAM Button once PROG 1 will appear on the right of the Display This indicates that the Clock is in Program Mode and that the first program step is ready to be entered Enter the first program time 7 00 am in our example by pushing the HOURS and TIME CONTROL MINUTES Buttons PROGRAM 4 FO
17. l additionally enable you to monitor your poo and spa temperatures from a convenient indoor location OUTDOOR REMOTE The 3 button Remote with status lights is also available with a hinged raintight cover for mounting in an outdoor location TELEPHONE REMOTE If your system incorporates a Telephone Module model MOD PHONE it is possible to access the control system and activate the equipment from any touch tone phone Consult the MOD PHONE Manual for details UNUSED PROGRAM STEPS Our sample program utilizes all six programs steps However your personal program may only require that you use three or four of the available program steps In this event we recommend that you disable all unused program steps To accomplish this push PROGRAM Button until unused program is displayed Push and hold down HOURS and MINUTES Mente et aka O Buttons at the same time and then release simultaneously OFF will appear on the Display To reactivate any disabled program step simply push HOURS Button once MUJER CLEA SPA AUXI OFF will disappear and the Clock can then be programmed K ggg REVIEWING PROGRAM After programming is complete it is possible to rapidly advance the Clock through a 24 hour period in order to review your program Make sure that Ciock is in Time Mode Push and hold down HOURS and MINUTES Buttons at the same time and then release simultaneously The Clock will rapidly advance through your program st
18. ncorporates solar heating it is advisable that a draindown feature be included to protect the solar panels against potential freeze damage For conventional solar systems which permit gravity drainage of panels the Compool Solar Valve with built in check valve model SOL 2T will automatically drain the panels whenever the solar turns off and the filter pump is not running For solar systems with glazed panels damage can occur from overheating if the solar turns off and the filter pump is still running In this instance a motorized Draindown Valve madel HW 5B should be plumbed at the solar feed line This will automatically drain the panels whenever the solar is turned off even if the filter pump is still running This feature may also be incorporated if your solar system does not facilitate gravity drainage of panels or where panels are located below pool water level Consult your Solar Company for more details 7
19. ons Pay special attention to the AM PM indicator In our example at 12 00 pm the filter pump and poo cleaner should turn off Make sure that OFF is displayed above each MINUTES Equipment Button FILTER CLNR SPA AUXI You have now completed the third program step Ak l 5 EA Push PROGRAM Button to lock in the program PE h ERE EE are PROG 4 will now appear on the right of the Display This indicates that the fourth program step is ready to be entered Enter the fourth program time 6 30 pm by PROGRAM pushing the HOURS and MINUTES Buttons OF O M ALTER CLNA SPA AUXI eee In our example at 6 30 pm the spa and OOOO s TIME CONTROL auxiliary 1 spa tight should turn on Push SPA Equipment Button ON should appear directly above the SPA and FILTER Buttons Push AUX1 Equipment Button ON should appear above AUX1 Button You have now completed the fourth program step Push PROGRAM Button to lock in the program PROG 5 will now appear on the right of the Display This indicates that the fifth program step is ready to be entered Enter the fifth program time 8 00 pm by PROGRAM apapa PROS ETE PM 5 nouns O pushing the HOURS and MINUTES Buttons OFF OFF OFF pere CLHR SPA AUXI z In Our example we would like to turn off the COO TIME CONTROL spa at 8 00 pm but the spa light AUX 1 should still be on Push AUX 1 Equipment Button ON will appea
20. osition SOLAR CONTROL Switch is in the AUTO position and OUTDOOR REMOTES Switch is in the ON position NOTHING OPERATES Check 3 amo circuit breaker which is located above faceplate in LX 10 Service Center Tripped circuit breaker is indicated by a white tab Push to reset 2 if circuit breaker continues to trip refer to a qualified Service Company 3 At the LX 10 turn OUTDOOR REMOTES Switch to the OFF position lf the equipment can now be operated there may be malfunction at your Spa side Remote Control 3 aes PUMP DOES NOT OPERATE At the CP 2000 check that FILTER Status Light is ON gt At the LX 10 turn SYSTEM CONTROL Switch to the SERVICE position and FILTER Switch at MANUAL CONTROL to the ON position 3 If filter pump operates there is a possible malfunction at the LX 10 circuit board 4 If filter pump does not operate pump may require servicing POOL CLEANER DOES NOT OPERATE 1 At the CP 2000 check that CLNR is switched ON and that four minute pool cleaner on delay has expired 2 At the LX 10 turn SYSTEM CONTROL Switch to the SERVICE position and CLNR Switch at MANUAL CONTROL to the ON position 3 If pool cleaner pump operates there is a possible malfunction at the LX 10 circuit board 4 If pool cleaner does not operate pump may require servicing 5 If system incorporates a pool cleaner valve check that cable has not been unplugged from Valve Operator Hadi DOES NO
21. pool model BAT 3 or can be purchased at Radio Shack or your local drug store Type CR2032 or equivalent CLEANING THE SPA For cleaning or maintenance purposes it is possible to use the Control System to automatically empty your spa and then to refill with ctean water from your pool At the LX 10 Service Center 1 Sal Set SYSTEM CONTROL Switch to the SERVICE position 2 Set FLOW CONTROL Switch to the DRAIN position 3 4 The spa will begin to drain into the pool Do not drain completely or prime will be lost At the MANUAL CONTROL set FILTER Switch to the ON position CAUTION Do not leave equipment unattended when draining or filling the spa When cleaning is complete set FLOW CONTROL Switch to the FILL position The spa will begin to fill with clean water from the pool When the spa water level has returned to normal return FLOW CONTROL Switch to the POOL position FILTER Switch at the MANUAL CONTROL to the OFF position and SYSTEM CONTROL Switch to the AUTO position WINTERIZING THE SYSTEM During the winter season it is possible to drain your poo and disable the pool equipment from your control system but still be able to use your spa Consult a qualified service company to drain your pool and protect the plumbing from freeze damage The following procedure will disable the pool equipment 1 At the LX 10 Service Center turn SYSTEM CONTROL Switch to the SERVICE position
22. prevent possible water damage the door of the LX 10 must be kept closed at all times Equipment Service Switches are located in the left side compartment There are no user serviceable components located behind service panel in the right side compartment Do not remove service panel Refer service to qualified personnel only SYSTEM CONTROL PATENT NO 432 297 This Switch should be kept in the AUTO position LX 10 for normal system operation SERVICE CENTER The SERVICE position will disable the CP 2000 Controller and provide your Pool Serviceperson SYSTEM CONTROL with complete manual override capability of all aeaa e TT MUSI BEISSERUICE POSITION 10 oeg pool equipment COMPUTER CONTROL AUTO i MANUAL CONTROL iono service Separate Service Switches are provided for activating the filter pump pool cleaner and FLOW CONTROL MANUAL auxiliary 1 circuit lights jet pump etc Dr NE asitiON CONTROL SYSTEM CONTROL MUST BE IN SERYICL POSITION a B FILTER However the SYSTEM CONTROL Switch must be in the SERVICE position before these Switches can be turned ON Note Always return MANUAL CONTROL Switches to the OFF position after equipment has been serviced SOLAR CONTROL AUTO COMPUTER CONTROL OFFJON MANUAL OYERAIDE LL 4 DRAIN POOL cincuration pa gt IE SPA SERVICE i pa E CLNR OFF orr M AUX OUTDOOR REMOTES FLOW CONTROL To enable this Switch the SYSTEM CONTROL Switc
23. r above AUX1 Button You have now completed the fifth program step Push PROGRAM Button to lock in the program PROG 6 will now appear on the right of the Display This indicates that the sixth program step is ready to be entered Enter the sixth program time 10 00 pm by TIME CONTROL pushing the HOURS and MINUTES Buttons In our example all of the equipment should be turned off at 10 00 pm Therefore make sure that OFF is displayed above all of the Equipment Buttons To lock in the program and return Clock to SEN See eee eee Time Mode simply push the PROGRAM J Button once i L a e H this is forgotten the Clock will automatically return to Time Mode after two minutes SYSTEM OPTIONS TWO SPEED PUMP CONTROL If your system incorporates a Two Speed Filter Pump the CP 2000 has been designed to provide you with the maximum energy efficient usage of this feature Although your Pool Builder may have adjusted the two speed control circuitry to your specific requirements the CP 2000 typically switches the pump to high speed under any of the following conditions 1 For two minutes when the filter is first turned on This features establishes proper flow through the system and packs the filter grids After two minutes the pump will automatically switch to low speed 2 Whenever the pool cleaner is running This provides sufficient flow for the pool cleaner to operate effectively 3 During spa operation to increase t
24. rporation or which have been damaged because of a defect in a component or part which is not part of the Compoo l Control System or upon which the serial number or manufacture date has been altered effaced or removed This warranty gives you specific legal rights and you may also have other rights which vary from State to State Compool Corporation does not authorize any person to create any other obligation or liability in connection with Compoot controls Compool Corporation makes no warranty of merchantability or fitness for any use Any implied warranty applicable to Compoo controls is limited in duration to the duration of this written warranty Unless state law provides otherwise Compool Corporation shall not be liable for consequential or incidental damages resulting from breach of this written warranty or any implied warranty or for any inconvenience loss of time or incidental expenses such as telephone calls Compooi Corporation shall not be liable for any labor charges associated with the removal or reinstallation of any so claimed defective products For information on possible Authorized Service Centers within your vicinity call Compoo Corporation at 415 964 2201 To exercise this warranty send defective unit with copy of dated receipt and a brief description of the problems encountered postage prepaid to COMPOOL CORPORATION 599 Fairchild Drive Mountain View California 94043 941 0451 OWNER S MANUAL CP
25. s off before spa attains the maximum temperature of 104 F the Controller may need a calibration adjustment SPA DRAINS OR OVERFLOWS 1 At the LX 10 check that FLOW CONTROL Switch is not in FILL or DRAIN position 2 Check that cables have not been unplugged from Valve Operators SPA WATER LEVEL DROPS SLOWLY 1 Valves may need servicing CONTROLLER Installed in a convenient location inside your house the CP 2000 CONTROLLER gives you fingertip control of all the equipment associated with your swimming pool and spa y gt CP 2000 A a REMOTE STATUS CONTROL DISPLAY MINUTES ren saat CLEANER spa S TEMPERATURE CONTROL clas i E SOLAR e SOLAN 4 WATER S Pree be Pee gt 5 VUMBPERATUAEL HEA as cH x i F OFF Jo E pe i TIME CONTROL The Controller houses an electronic time clock for programming the daily operating cycles of your pool equipment There are four Equipment Buttons which are used for turning the equipment ON and OFF FILTER Button Activates filter pump and circulates water for pool filtration Enables poo to be heated CLNR Button Activates poo cleaner after 4 minute delay and also filter pump if FILTER Button is not already switched ON SPA Button Activates filter pump and rotates valves to spa circulation Enables spa to be heated Disables the CLNR Button and turns pool cleaner OFF AUX 1 Button Activates auxiliary equipment such as sp
26. switches to conventional heating when solar energy is unavailable HEATER Position Allows heating with gas or electric heater only Note If you are heating the swimming pool and also the spa in some Custom applications the solar system may also contribute to the conventional heat whenever solar energy is available OFF Position Allows no heating WATER TEMPERATURE Display Whenever the filter pump is running the precise water temperature will be displayed in degrees Fahrenheit Pool temperature will be displayed during pool circulation and spa temperature displayed during spa circulation Note Filter pump must be running in order to provide accurate temperature display VALVE OPERATORS Your control system is designed to actuate two motorized valves which automatically rotate between pool and spa filtration whenever the SPA Button at the CP 2000 is activated A motorized valve may also be used to automatically divert the flow of water through your solar panels whenever solar energy is available These Valve Operators are also activated by the FLOW CONTROL and SOLAR CONTROL Switches at the LX 10 Service Center Your system may also include additional motorized valves for custom hydraulic applications such as a fountain or waterfall or in lieu of a booster pump to activate your pool cleaner SINGLE OCCURRENCE PROGRAM Occasionally you may wish to use your spa at a time which is different from your normal daily progr