Home

Agilent 5973N Data Sheet

image

Contents

1. OFN using MS detection and automated integration and processing Specifications using a different compound concentration detectors or conditions are not comparable lt 0 0012 min lt 2 0 RSD Trace RT repeatability Trace area repeatability Safety Regulatory Compliance and Operational Conditions The instrument is designed and manufactured under a quality system registered to ISO 9001 The instrument complies with international regulatory safety and elec tromagnetic compatibility requirements The specifica tions are more conservative than actual test conditions In addition further testing was done under Agilent stan dards to assure operation after delivery and long term usage See http www chem agilent com cag aboutapg aboutQuality htmlfor further information and typical product testing videos Canadian Standards CSA Safety Association C22 2 No 1010 1 CSA Nationally Recognized Test Laboratory NRTL UL 61010A 1 International Electrotechnical Commission IEC 61010 1 EuroNorm EN 61010 1 Electromagnetic compatibility CISPR11 EN Group 1 Class A IEC EN 61326 Australian NZ C tick Canadian ICES 001 EN 27779 1991 sound pressure Lp lt 70 db 120VAC 5 10 50 60 Hz 5 200 240VAC 5 10 50 60 Hz 5 15 35 C 40 80 relative humidity noncondensing operational 20 70 C 0 95 relative humidity noncondensing storage Sound emission Power Op
2. GC MS The Agilent 5973N Gas Chromatograph Mass Spectrometer GC MS is the latest in the Agilent 5973 series of mass selective detec tors MSDs The Agilent 5973N improves on previous models by incorporating local area network LAN communication between the instrument and the GC MS ChemStation Up to two GC MSs can be controlled by a single ChemStation A local user interface on each instrument allows basic operations to be performed even when the computer is located on another bench The Agilent 5973N system is reten tion time locking RTL ready RTL is a unique Agilent feature that allows creation of permanent and universal methods Using RTL meth ods the retention times RTs do not change even with column main tenance The same RTs will be obtained on the GC MS as they will on GCs with conventional detectors It allows exact matching of peaks across multiple instruments whether in the same lab or in another country RTL databases for Agilent 5973N GC MS System Data Sheet specific compound classes allow for rapid screening of a large number of compounds without injecting hundreds of standards The Agilent 5973 series instruments are known for their reliability ruggedness and long life The Agilent 5973N system offers even greater value with a 10 year use guarantee whether it is purchased in the first or last year of produc tion This guarantee provides greater assurance for low cost of ownership Th
3. e Agilent 5973N GC MS features e Proven ruggedness and reliability e Greater mass stability better than 0 10 amu over 48 hours e Performance electronics for 10 000 amu s scan speed 8 000 amu s write to disk e Enhanced software e RTL ready e Compatible with microfluidics flow controller Compatible with flip top inlet sealing system Short GC interface lt 20 cm Independently heated zones transfer line source quad Proprietary hyperbolic gold coated quadrupole Heatable quadrupole to 200 C Easy access to full ion optics High energy dynode and electron multiplier detector Two MS control per PC Four simultaneous signal acquisitions up to 2 MS Intelligent sequencing for samples Upgradable to inert electron impact EI source for reactive compounds Compatibility with many third party sampling devices Optional 21CFR11 compliance software Ten year use guarantee 2 Agilent Technologies Agilent 5973N GC MS System Data Sheet Mass Spectrometer Mode lon source type lonization energy lonization current Transfer line temperature lon source temperature Quadupole temperature Mass filter Mass filter protection Mass range Mass resolution Mass axis stability Detector Dynamic range electronic Scan rate electronic Write to disk SIM Pumping system Total flow Instrument control Maintenance access Maintenance scheduling Gas Chromatograph Automatic injecto
4. erating environment For More Information For more information on our products and services visit our Web site at www agilent com chem www agilent com chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Information descriptions and specifications in this publication are subject to change without notice Agilent Technologies Inc 2004 Printed in the USA November 29 2004 5989 0082EN Agilent Technologies
5. olution pressure and temperature corrected RTL ready Compatible with optional microfluidics controller Four signals up to 2 MS detector data acquisitions El PCI NCI BFB DFTPP Automated Environmental drugs of abuse aromatics in gasoline Sequence file quant and custom report Macro language report writer Password and audit trail NIST Wiley Pfleger Mauer Drug Stan pesticide Pesticides and endocrine disrupters volatiles PCBs toxicology FAMEs flavors organotin compounds Optional software available Deconvolution linked with RTL database Ten year use guarantee Physical El system with standard turbo Dimensions Weight 88 cm w x 56 cm d x 50 cm h 88 kg Installation Checkout Specifications All tests performed using an autosampler capillary injector and a 30 m x 0 25 mm x 0 25 um HP 5MS column All scan determinations use continuous linear scanning across the entire mass range Noise selection peak integration and RMS s n calculation performed by automated macro Specifications are not comparable to those using different conditions The system will exceed the following specifications at installation El scan sensitivity 20 1 s n for 1 pg OFN scanning from 50 300 amu at nominal m z 272 ion Other Sensitivity Specifications 10 1 s n for 20 fg OFN at nominal m z 272 ion EI SIM sensitivity Trace Repeatability Results are for three replicate splitless injections of 1 pg
6. r optional Liner replacement Injector Oven temperature El Stainless steel source upgradable to inert El source 5 241 5 eV 0 315 pA 100 C 350 C 150 C 250 C 150 C 200 C Monolithic hyperbolic quadrupole Entrance lens 1 6 800 amu Unit mass adjustable by tune Better than 0 10 amu 48 h Electron multiplier with replaceable horn 10e6 10 000 amu s 8 000 amu s 30 ions x 50 groups Diffusion pump 1 5 mL min Data system and local user interface Source filaments lenses mass filter and detector on removable plate Early maintenance feedback Automatic alignment fast injection Compatible with optional flip top inlet sealing system Capillary standard others available Ambient 4 C 450 C Oven ramps plateaus Carrier gases Electronic pneumatic control Carrier gas control modes Pressure range Retention Time Locking Flow control Data system Simultaneous MS and GC lonization mode autotunes Application autotunes Quantitation setup Application reports File import export Customization Security Spectral libraries optional Spectral and RTL databases optional 21CFR11 Compliance Other capabilities optional Support life 6 7 Helium hydrogen nitrogen argon Auto pressure regulation for capillary septum purge Constant pressure and flow modes pressure and flow programmable 0 100 psi standard 0 150 psi optional with 0 01 psi res

Download Pdf Manuals

image

Related Search

Agilent 5973N Data Sheet agilent 5973 msd manual agilent-5977b agilent 5977 msd manual agilent/5975c agilent 6890n-5973 agilent technologies 5977b msd agilent 5977b transfer line agilent 5975 cleaning ion source agilent 6890n-5975 agilent 5977a msd system agilent 5977b gc/msd agilent 5975 ei source agilent 5977 source cleaning agilent 5977b source cleaning agilent 5977c gc/msd agilent 5975c column installation agilent 6890n-5973 gc-ms agilent 5973 mass selective detector agilent gcms 5977b manual agilent 7890 a-5975c agilent 5971 top board agilent 7890b/5977 agilent 7890a/5975c agilent 7890b/5977b agilent 7890b/5977a