1. e Specifications General CombiPAL Specifications in Liquid Mode System type Local user interface Electrical control Dimensions Weight GC mounting kits Syringe sizes Injection speed XYZ robot with syringe only concept Control panel with 4 function keys graphical LCD display unique scroll knob for teach functions 2 RS232C ports 3 TTL input 3 TTL output 2 Opto Coupler input 2 Relay output Length 828 mm depth 385 mm height 648 mm 10 kg without accessories Agilent 7890A 6850 and 6890 1 2 pL 5 pL 10 pL standard 25 pL 100 pL 250 pL and 500 pL Selectable from 0 01 uL sec up to 500 pL sec Specifications in Headspace Mode CombiPAL Only Syringe sizes Injection speed Sample capacity Syringe cleaning 1 0 mL 0 1 1 0 mL 2 5 mL 0 25 mL 2 5 mL 5 0 mL 0 5 mL 5 0 mL Selectable from 0 01 uL sec up to 5 mL sec Up to 294 2 mL standard vials Up to 96 10 mL or 20 mL vials Inert gas purging of heated syringe GC PAL Specifications System type Local user interface Electrical control Dimensions Weight GC mounting kits Syringe sizes XYZ robot with syringe only concept Control panel with 4 function keys graphical LCD display unique scroll knob for teach functions 2 RS232C ports 3 TTL input 3 TTL output 2 Opto Coupler input 2 Relay output Length 828 mm depth 385 mm height 575 mm 10 kg without ac
2. C in 1 C increments Interval shaking 250 rpm 750 rpm selectable in 1 rpm increments Up to 999 minutes selectable in 1 second increments PAL SPME Selectable from 0 01 uL sec up to 500 pL sec Up to 600 1 mL micro vials 78 1 mL vials standard Up to 294 2 mL standard vials 98 2 mL vials standard Up to 96 10 mL or 20 mL vials Up to 4 deepwell microplates 96 384 wells Up to 8 standard microplates 96 384 wells Wash Station for 2 different solvents standard Thermostatted trayholders 4 C 70 C Stack for 96 384 well micro or deepwell plates Solvent reagent reservoir Large Volume Wash Station 100 240 V 120 W 50 60 Hz 4 C 40 C constant temperature lt 80 humidity noncondensing z Agilent Technologies www agilent com chem Agilent CTC Pal Control Software and EZChrom Elite Drivers CTC Pal Autosampler Parameters Controlled Through GC Chem Station GC MSD ChemStation and EZChrom Elite in Various Modes Liquid Headspace SPME Syringe size Syringe size Fiber expose time Sample volume Sample volume Pre inc time Air volume Incubat temp Agi speed Pre cln slv1 Incubat time Agi on time Pre cln slv2 Agi speed Agi off time Pre cln spl Syring temp Vial penetr depth Fill speed Fill speed Extract time Fill strokes Pullup del Desorb to Inject to Inject to Inj penetr Inject speed Inject speed Inj penetr depth Pre inj delay Pre inj del Desorb time Pst inj delay Pst inj del Fiber ba
3. cessories Agilent 7890A 6850 and 6890 1 2 uL 5 pL 10 pL standard 25 pL 100 pL 250 uL and 500 uL Note Specifications on this page refer to the Combi Pal and GC Pal hardware See page 2 for software driver capabilities Sample capacity Syringe cleaning Options Power requirements Environment Heated syringe Incubator oven Incubation temperature Agitation Incubation time Option Injection speed Sample capacity Syringe cleaning Options Power requirements Environment Depends on GC model Specifications at a Glance Up to 600 1 mL micro vials 78 1 mL vials standard Up to 294 2 mL standard vials 98 2 mL vials standard Up to 96 10 mL or 20 mL vials Up to 4 deepwell microplates 96 384 wells Up to 8 standard microplates 96 384 wells Wash Station for 2 different solvents standard PAL Headspace option requires CombiPAL basic liquid version PAL SPMEoption requires CombiPAL basic including headspace option Cooled trayholders for 1 mL 2 mL 10 mL and 20 mL vials SPME Fiber Cleaning Station Stacks for 96 384 well micro or deepwell plates Solvent reagent reservoir Large Volume Wash Station 100 240 V 120 W 50 60 Hz 4 C 40 C constant temperature lt 80 humidity noncondensing 30 C 150 C selectable in 1 C increments 6 heated vial positions for 2 mL 10 mL 20 mL vials 30 C 200
4. keout Pst cln slv1 Syr flushing Pst cln slv2 CTC Pal Autosampler control software or EZChrom Elite is required for integrated software control The Agilent CTC Pal ChemStation drivers currently feature next sample overlap Multiple sample overlap is not a feature of the drivers In general multiple sample overlap would only be required when the customer has methods in which the GC run time is less than the heating agitation time of the Pal headspace accessory Customers needing multiple sample overlap capability through Chem Station should consider the G1888A Headspace Sampler and associated software control They may also consider standalone control of the Pal Autosampler With Agilent EZChrom Elite drivers custom cycles can be imported which have been developed in Cycle Editor Note Cycle Editor is not available for sale by Agilent For More Information For more information on our products and services visit our Web site at www agilent com chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Information descriptions and specifications in this publication are subject to change without notice Agilent Technologies Inc 2007 Printed in the USA November 7 2007 5989 7600EN Agilent Technologies

Download Pdf Manuals

image

Related Search

Agilent Specifications at a Glance Manual agilent gc ms manual specification at a glance agilent power supply manual agilent mass spectrometer manual agilent 1200 service manual agilent spectrum analyzer manual agilent 1200 series manual agilent 5977b maintenance manual agilent icp ms manual agilent g7104a user manual agilent quantitative analysis manual agilent mass spec software agilent spectrum analyzer user manual agilent 4155c service manual agilent gc troubleshooting guide pdf agilent gc troubleshooting pdf agilentg4502a_07_3 agilent lab advisor manual agilent 1100 series manual agilent 5975 troubleshooting manual agilent 5973 msd manual agilent instant pilot manual agilent gc/ms 5977 manual agilent technologies application notes

Related Contents

                Pioneer PDP-607CMX/PDP-507CMX/PDP-427CMX Plasma Display Operating Instructions    

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.