Home

Agilent Thermo Electron LC Control Software for EZChrom Elite CDS Agilent OL Manual(1)

image

Contents

1. Ef Advanced Medium Push loop tm Zar Custom Report High C Pull loop i PDA Options ja paa Flush volume 400 E B Tiled Display i E Integration Event Needle height from bottom 2 EA 5 Peaks Groups Table Tray temp control Column oven wa z E34 Manual Integration On gt OF C On Temp 18 I Prep only method eoeoooocoR 0066 0 00 oooo ooo or moO 60 0066 9010 0100000 oo 60 6006 00 616010 O S ooO 610 010 606 moO 66 6 OO 6 O60 60 010606 0610 010 66 oo 660 C10 6G Figure 2 Tabbed instrument method setup screens and autosampler tray graphics make it easy to develop methods and sequences Special EZChrom Single Instrument Version A special EZChrom SI single instrument version for the spectraSYSTEM HPLC is available for users who have only one Thermo SpectraSYSTEM LC and who require only basic EZChrom Elite features This provides instrument control of the spectrasYSTEM LC with a broad range of chromatography data handling capabilities at a very attractive price Security and Regulatory Compliance Agilent s security and compliance tools for EZChrom and Agilent OL allow users to address regulations such as FDA s 21 CFR 11 for electronic records and signatures Audit trails are comprehensive recording every event starting from file creation Once electronically signed data files cannot be reanalyzed or modified All audit trails provide who what when and why
2. The entire SpectraSYSTEM LC product line of pumps autosamplers UV detectors Fluorescence detectors and PDA detector can be controlled through this optional instrument control software Intelligent Auto Configuration Configuring a system has never been simpler A special Autoconfiguration mode in EZChrom Elite or Agilent OL automatically identifies all SoectraSYSTEM connected modules and configures them to the software system without end user intervention The configura tion is then saved and the user subsequently develops methods appropriate to that specific configuration rather than for a generic HPLC or GC configuration Thermo Electron LC Control Software for EZChrom Elite CDS and Agilent OL Operating Specifications Control is included for the following modules The Model SN4000 interface is required e Models P1000 isocratic P1500 binary P2000 binary gradient and P4000 quarternary Pumps e Models AS1000 and AS3000 including the Sample Prep option e Model UV6000LP Photodiode Array Detector e Models UV1000 UV2000 and the UV3000 scanning UV detector e Models FL2000 and FL3000 Fluorescence detectors is Agilent Technologies Easy Access to Status and Control End users benefit from a convenient tabbed status dialog that provides detailed real time status on a component by component basis With parameter modification and run management only a few mouse clicks away users have complete control of the
3. Manage All Instrument Data with Agilent OL Thermo SpectraSYSTEM Firmware Requirements The unique Agilent OL Operating System for the Laboratory EZChrom Elite and Agilent OL control of the Thermo Electron provides powerful content management of all raw data and results SpectraSYSTEM HPLC and associated components requires the from the Thermo LC systems Smart electronic filters specific for following firmware requirements the Thermo LC results are used to extract key metadata from each LC run and store that information in a database All results are System Controllers Version automatically deposited in a safe secure repository and made fully SN4000 9 05 searchable Pumps Version Users can readily find their data based on queries that not only P1000 4 01 or higher specify criteria such as instrument username and Sample ID but P1500 4 02 or higher even extend to detailed results such as component names and P2000 4 03 or higher concentration ranges P4000 4 04 or higher Agilent OL manages all the electronic information in the laboratory Autosamplers Version In addition to all Thermo SpectraSYSTEM LC raw data and results AS1000 3 31 or higher Agilent OL can manage Microsoft Office files e mails Adobe pdf AS3000 3 31 or higher files chromatography data from EZChrom Elite and other CDS AS3500 3 31 or higher packages mass spectrometry files and much more No other AS2000 3 13 or higher package offers this powerful capability to handl
4. System for the Laboratory i File Edit View Method Data Sequence Analysis Control Reports Window Help iT a E z A 1 Detector 1 254nm 7 EA gp Instrument Setup j k Integration Events Run time Peaks Groups E Review Calibration M Scans fio min Rise time 20 sec Advanced Min wavelength 220 nm Scanrate 1 0 vj Hz Max wavelength 360 nm Bandwidth 5 v nm Typical file size 170 KB Custom Report g PDA Options a Data Step 2 x K Tiled Display 4 Integration Event FS Peaks Groups Table FS Vv Discrete Channels 1 ai Wavelength A 254 nm Wavelength B 2s D nm Wavelength C 22 1 nm Data rate fioo Hz Bandwidth 11 v nm Bandwidth 11 zi nm Bandwidth 11 Y nm m Lamp Options V Deuterium Lamp On IV Tungsten Lamp On J Shutdown method J Prep only method For Help press F1 Figure 1 EZChrom Elite and Agilent OL control of the Thermo LC family includes full digital support for all components inlcude the PDA detector Control Thermo Electron s SpectraSYSTEM LC One of the world s most popular LC systems Thermo Electron s SpectraSYSTEM LC can be fully controlled through both the EZChrom Elite CDS and Agilent OL Operating System for the Laboratory This allows the SpectraSYSTEM HPLC to be integrated into Agilent Technology s impressive library of more than 300 different supported instrument modules in EZChrom Elite and Agilent OL
5. and are CRC checksummed to prevent unwanted manipulation Scalable and Flexible Deployment EZChrom Elite and Agilent OL provide a wide range of flexible deployments Whether your needs call for a single user workstation or a large client server operation or the use of web clients across the enterprise EZChrom Elite and Agilent OL can provide the ideal solution for collecting data and controlling the Thermo LC systems Fully Protected Data Acquisition and Control The unique data acquisition and instrument control architecture in EZChrom and Agilent OL make it possible to perform data collection even in the event the host computer network is down The special Agilent Instrument Controller acts as a network appliance and can take control of each SpectraSYSTEM LC The Agilent Instrument Controller can run injections collect and protect the data com pletely If the network is down these injections will be securely stored in special flash RAM in each Agilent Instrument Controller The data storage in each Agilent Instrument Controller allows multiple injections from entire sequences including injections based on different methods to be safely stored and protected so your Instrument runs can continue under such serious network problems Up to four 4 SpectraSYSTEM LCs non PDA can be connected to a single Agilent Instrument Controller and up to two 2 spectraSYSTEM LCs with PDA can be connected to a single Agilent Instrument Controller
6. e all electronic HS2000 3 1a or higher information and documents generated in the laboratory Conduct quick focused searches across all your data to find hits from Note Autoconfiguration feature only works on version 3 41 or higher various Thermo SpectraSYSTEM HPLC results as well as Excel Detectors Version spreadsheets Word documents pdf reports and more UV1000 3 09 or higher UV2000 3 12 or higher Furthermore Agilent OL s management of the information makes it UV3000 all revs easier and safer to collaborate and share results with others with its FL2000 3 11 or higher powerful check in check out capabilities and Electronic signoff FL3000 3 11 or higher capabilities UV6000 RAM 1 4 Hardware Requirements spectrasYSTEM LC control is by RS232 to the Thermo SN4000 interface A serial port is required for the SN4000 interface An additional serial port is required for the UV6000LP PDA and or UV3000 scanning detector Visit www agilent com chem scisw or call toll free 1 800 227 9770 U S and Canada In other countries please call your local Agilent Technologies analytical sales office or Authorized Agilent Technologies Distributor This information is subject to change without notice Agilent Technologies Inc 2006 Printed in U S A November 3 2006 5989 4302EN whee Agilent Technologies
7. ir system For further assistance EZChrom Elite s built in software Wizards make developing new sequences and methods a breeze Superior Diode Array Data Handling In addition to the standard 2 dimensional SpectraSYSTEM instrument control an additional SpectraSYSTEM PDA Analysis and Control Software for EZChrom or Agilent OL supports the SpectraSYSTEM PDA detector This additional software can fully control the PDA detector and provide PDA software analysis It provides an unlimited number of acquisition and analysis channels All data are saved in a single data file so any chromatograms or spectra can be recalled for review after analysis With the complete data acquisition and powerful visualization capabilities in the software even minor components are easily detected and reported Complete Autosampler Control The wide variety of autosampler controls for the SpectrasYSTEM are fully supported including heating and cooling options and Sample Preparation options This enables a flexible treatment to be applied for all injections under the complete control of software Jog i Thermo Spectra System LC Method untitled met Data PNA_Level_3_vp dat Project Default i File Edit View Method Data Sequence Analysis Control Reports Window Help gt E amp z 1 Detector 1 254nm x 6 das Rls fi a ES Instrument Setup Integration Events Injection type C Fullloop Peaks Groups Sample viscosity 4 Review Calibration Hormat

Download Pdf Manuals

image

Related Search

Related Contents

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.