Home

Agilent LC/MS Nitrogen Generators for use with Varian LC/MS Instruments Manual

image

Contents

1. 4 LC MS Nitrogen Generators for use with Varian LC MS Instruments domnick hunter s LC MS nitrogen generators are specifically designed to meet the gas flow purity and pressure requirements of the entire range of Varian LC MS instruments including the 320 MS Single or Triple Quadrupole as well as the 500 lon Trap Flow rates range from 12 L min to 40 L min and provide complete flexibility allowing single or multiple instruments to be supplied by one generator In addition the domnick hunter LCMS12 2 is the only single system solution on the market suitable for use with both ionization modes of the Varian LC MS instruments The generator employs a pressure swing adsorption technique to deliver continuous streams of clean dry nitrogen and air without the need for secondary purification When operating the LC MS in positive ionization mode nitrogen is used for drying auxiliary and nebulizing gas The Features Suitable for nebulizing auxiliary and drying gas Fully regenerative proven durability PSA technology Phthalate free Integral oil free compressor optional Soundproofed compressor box Digital Interface CE UL and CRN approved Global manufacturing support NOTICE This document contains references to Varian Please note that Varian Inc is now part of Agilent Technologies For more information go to www agilent com chem ie Agilent Technologies generator also produces clean dry air for use as
2. N2 Ae N2 Varian Instrument 320 MS or 500IT G4 510W 12 es C ecsio v os EE EE armes wi o a as aea Porm s area aans sonlis a 2 as tap o isoa e soed a a a pxttaesersam wowsso wwe 90 o o oee a a remsso vows o eee e pa we extasersmm vewsco ow 1 Swanson Swagecer KEE e a EE with integral compressor Connections N3 Air Voltage outlet AC 4 Swagelock 115 4 Swagelock f 230 outlet oe a Dimensions ins Weight lbs The 320 MS is the new replacement instrument for the 1200L The same gas generators that work for the 320 MS are also compatible with the 1200L instruments G4 510 G4 600 LCMS 12 2 LCMS 30 40 To ensure optimum performance and longevity of your LC MS nitrogen air generator domnick hunter recommends the following service kits be used as part of a preventative maintenance program Filter Kit Moge every 4000 hours Com orm o omm 115 VAC Models Compressor Kit every 8000 hours Valve Kit every 24000 hours Also required at 24000 hours if no compressor fitted LCMS 40 0W 60 627 2251 60 627 2263 60 627 2265 seine orm OO re 230 VAC Models LCMS 40 0E 60 627 2251 Se 60 627 2255 60 627 2257 with integral compressor For more information on extended warranty and preventative maintenance contract availability please contact your local domnick hunter sales office or log
3. nebulizing gas in the negative ionization mode Models featuring integral oil free compressors give increased security of supply completely removing the reliance on an external compressed air source All domnick hunter products are built with ease of use and reliability as the two most important criteria We recognize that our generators are supporting critical applications and the goal of maximum uptime is of paramount importance In pursuit of this goal total support preventative maintenance agreements are available for purchase with any of our systems ensuring peace of mind while providing a fixed cost of ownership and automatic extension of the manufacturer s warranty for up to 10 years Benefits E Improved instrument performance Guaranteed consistent nitrogen purity improves stability and ensures greater reproducibility of results m Low and stable gas supply costs Payback in less than 18 months E Single box solution Fewer connections less hassle mM Security of supply Integral oil free compressors removes the reliance on dedicated compressed air supplies m Reduced Health and Safety risks No manual handling or high pressure gas storage m Peace of mind Service contracts and extended warranty available m Effortless operation Nitrogen and air at the push of a button m Expert advice Over 20 years experience of PSA system design Technical Specifications Ta domnick hunter Flowrate L min Purity 02 Generator
4. on to www domnickhunter com scientific Varian Part Number DHUHPLCMS12W DHUHPLCMS12E DHUHPLCMS18W DHUHPLCMS18E DHLCMS1221W DHLCMS1221E pass thru pass thru pass thru pass thru dh Model Number G4 510W G4 510E G4 600W G4 600E LCMS12 2 1W LCMS12 2 1E LCMS30 1W LCMS30 1E LCMS40 0W LCMS40 0E conditions of sale www domnickhunter com scientific dh and domnick hunter are registered trademarks of Parker Hannifin Corporation domnick hunter has a continuous policy of product development and although the Company reserves the right to change specifications it attempts to keep customers informed of any alterations This publication is for general information only and customers are requested to contact our Industrial Division Sales Department for detailed information and advice on a products suitability for specific applications All products are sold subject to the Company s standard pis BSI ISO 9001 2000 Q 05240 HE QUEEN S AWARDS FOR ENTERPRISE ESS F Da CAGI 4 Ss inst MEMBER a division of Parker Hannifin Corporation A domnick hunter 5900 B Northwoods Pkwy jea Charlotte NC 28269 Tel 800 345 8462 Telefax 704 921 1960 htt www domnickhunter com 2006 Parker Hannifin Corporation Publication Reference Varian LCMS N2 Rev 001 USA 12 06

Download Pdf Manuals

image

Related Search

Agilent LC/MS Nitrogen Generators for use with Varian LC/MS Instruments Manual

Related Contents

  IntelliTouch Valve Module Installation Instructions                  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.