Home

Agilent 1290 Infinity Autosampler Manual

image

Contents

1. Agilent 1290 Infinity Autosampler Features Specifications and Ordering Details Fast Sample Injection with Highest Precision and Lowest Carryover The 1290 Infinity Autosampler is part of the 1290 Infinity LC system that is compatible with operating pressures up to 1200 bar It features the next generation flow through design for high precision injection of both large and small volumes without the need to change sample loops Only the injected volume is required from the sample and no valuable sample is wasted for flushing Inert materials in the metering device seal and needle seat as well as reduced hydraulic volumes achieve extremely low carryover A new module the 1290 Infinity Flexible Cube combines seamlessly with the autosampler for infinite injection flexibility The Flexible Cube facilitates fixed loop injection mode for ultra fast cycle times as well as automatic backflushing of the autosampler s needle seat for lowest carryover yet Features e Next generation flow through design with ultra low system volume for operation up to 1200 bar e Highest injection precision for both large and small volumes without changing loops e No waste of valuable sample for flushing e Short injection cycles for higher productivity through overlapped injections e Best carryover performance through inert seal and needle seat material as well as backflush of needle seat requires 1290 Infinity Flexible Cube e New cartridge loop for ultimat
2. RRLC Includes loop and analytical head Agilent 1260 Infinity High Performance Micro Autosampler Includes micro autosampler with well plate tray 2 x 54 2 mL vial plate electrically actuated Rheodyne micro injection valve and 0 5 m CAN cable Agilent 1260 Infinity Preparative Autosampler Includes 100 vial 2 mL thermostatted tray 15 x 6 mL half tray 2x MBB Rheodyne injection valve and 0 5 m CAN cable Agilent 1260 Infinity Dual Loop Autosampler Includes dual loop autosampler with two loops tray for two well vial plates and 10 x 2 ml vials Rheodyne injection valve Agilent 1290 Infinity Autosampler Includes well plate tray for two well plate and 10 x 2 mL vials 2 x 54 2 mL vial plate 1200 bar Rheodyne injection valve and 0 5 m CAN cable Agilent 1290 Series Thermostat Includes Peltier device to control the temperature of the Agilent 1200 Infinity Series autosamplers fraction collectors and spotters Agilent 1260 Infinity Manual Injector Includes 600 bar Rheodyne manual injection valve 20 uL sample loop and mounting stand Product Number G1329B G1329B 020 G1329B 021 G1367E G1367E 021 G1367E 040 G1377A G2260A G2258A G4226A G1330B G1328C www agilent com chem 1200 Agilent Technologies Inc 2010 Published in USA July 1 2010 Publication Number 5990 6123EN Agilent Technologies
3. e ease of use e Flexible and convenient sample handling with different types of sample containers such as well plates and vials process up to 768 samples unattended with 384 well plates e Peltier temperature control from 4 to 40 C for thermally labile samples requires 1290 Infinity Thermostat hE Agilent Technologies Specifications Agilent 1290 Infinity Autosampler Controller area network CAN RS232C APG remote standard optional four external contact closures and BCD vial number output Communications Safety features Leak detection and safe leak handling low voltages in maintenance areas error detection and display 0 1 20 pL in 0 1 pL increments Injection range Up to 40 uL with separate 40 uL loop Up to 100 uL with separate hardware Injection precision lt 0 25 from 5 40 pL lt 0 5 from 2 5 pL lt 0 7 from 0 5 2uL Injection accuracy 1 10 uL n 10 Sample viscosity range 0 2 5cp Sample capacity 2 x well plates MTP 10 2 ml vials 108 x 2 mL vials in 2 x 54 vial plate plus 10 additional 2 mL vials 30 x 6 mL vials in 2 x 15 vial plate plus 10 additional 2 mL vials 54 Eppendorf tubes 0 5 1 5 2 0 mL in 2 x 27 Eppendorf tube plate Compatible with the Agilent 1200 Series Sample Capacity Extension for further expansion of the sample capacity Injection cycle time Typically lt 21 s using following standard conditions Default draw speed 200 pL min Default eject speed 200 pL min Injection vo
4. lume 5 pL Carryover Typically lt 0 004 using the following condition Column 2 1 x 50 mm ZORBAX SB C18 1 8 pm Sample Chlorhexidine dissolved in water 0 1 TFA Mobile phase water 0 05 TFA acetonitrile 09 045 TFA Flow rate 0 5 mL min Gradient at 0 min 30 B at 3 min 60 B Injection volume 1 pL external needle wash with water 0 1 TFA draw and inject speed 100 pL min Column temperature 50 C MSD API ES positive SIM ion 505 30 Fragmentor 70 Gas temperature 250 C Drying gas 12 L min Vcap 3000V GLP features Early maintenance feedback EMF electronic records of maintenance and errors 100 pL loop 100 uL analytical head 600 bar rating Ordering Details Agilent 1200 Infinity Series Autosamplers Description Agilent 1260 Infinity Standard Autosampler Includes 100 vial 2 mL thermostatted tray 40 vial 2 mL tray 15 vial 6 mL tray electrically actuated 600 bar Rheodyne injection valve and 0 5 m CAN cable Expanded injection range with 900 yL syringe head loop capillary and injector needle installed and tested in the sampler Multi draw kit with loop capillaries to inject 500 and 1500 uL volume Agilent 1260 Infinity High Performance Autosampler Includes well plate tray for two well plate and 10 x 2 mL vials 2 x 54 2 mL vial plate 600 bar Rheodyne injection valve and 0 5 m CAN cable Multi draw kit with loop capillaries to inject 500 and 1500 uL volume 40 pL injection kit for

Download Pdf Manuals

image

Related Search

Agilent 1290 Infinity Autosampler Manual agilent 1290 infinity autosampler manual agilent 1290 infinity ii autosampler manual agilent 1290 infinity ii manual agilent 1290 infinity ii user manual agilent 1290 multisampler manual agilent infinity 1290 ii agilent technologies 1290 infinity agilent technologies 1290 infinity ii agilent 1290 infinity ii pump manual agilent 1290 infinity lc system agilent 1290 infinity lc agilent 1290 vialsampler manual agilent 1290 infinity ii lc agilent 1290 infinity ii lc system agilent 1260 infinity ii autosampler manual agilent 1290 pump manual agilent 1290 valve drive agilent 1290 infinity ii hplc agilent 1290 infinity ii uplc agilent 1290 infinity uplc agilent 1290 infinity ii lc-ms agilent 1290 infinity ii uhplc system

Related Contents

    FAIRCHILD FDS6680AS 30V N-Channel PowerTrench SynchFET(TM) Manual  YAMAHA CLP-611/811 OWNER'S MANUAL              

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.