Home

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61-700 MODEL: 61-701 MODEL: 61-702 MODEL: 61-704

image

Contents

1. Page 9 Battery Replacement refer to Figure 5 1 Disconnect the test leads from any circuit under test and turn off meter 2 Use a Philips head screwdriver to remove the screws on battery cover 3 Remove battery from the battery compartment 4 Install new 9V battery NEDA 1604 An alkaline type is recommended 5 Install new battery into compartment using care to install to proper polarity 6 Reinstall battery cover Figure 5 Form number TM61700 1 2 4 Rev 4 September 2004
2. IDEAL INDUSTRIES INC TECHNICAL MANUAL MODEL MODEL MODEL MODEL 61 700 61 701 61 702 61 704 The Service Information provides the following information e Precautions and safety information e Specifications e Performance test procedure e Calibration and calibration adjustment procedure e Basic maintenance replacing the battery Form number TM61700 1 2 4 Revision 4 Date Sept 2004 Form number TM61700 1 2 4 Rev 4 September 2004 TABLE OF CONTENTS Title Page Introduction Precautions and Safety Information Symbol Table Safety Information Indicator Functions Certifications and compliance Specifications General Specification Voltage Specifications Current Specifications Resistance Specifications Frequency Specification Capacitance Specifications HRB P HB HL HP Wl wi ni wn NK KH 5 Diode Continuity Specifications Performance Verification 5 6 Calibration 6 7 Calibration Reference Points 8 Replacing the Battery 9 Form number TM61700 1 2 4 Rev 4 September 2004 Page 1 Introduction Warning To avoid shock or injury do not perform the verification tests or calibration procedures described in this manual unless you are qualified to do so The information provided in this document is for the use of qualified personnel only A caution The 61 700 series contains parts that can be damaged by static discharge Follow
3. property ZA WARNING These statements identify conditions or practices that could result in personal injury or loss of life Specific precautions Do not operate without covers To avoid personal injury do not apply any voltage or current to the product without the covers in place Electric overload Never apply a voltage to a connector on the product that is outside the range specified for that connector Avoid electric shock To avoid injury or loss of life do not connect or disconnect probes or test leads while they are connected to a voltage source Do not operate in wet damp conditions To avoid electric shock do not operate this product in wet or damp conditions Indicator Functions e Hi V In ACV DCV Resistance and Continuity Diode test the end user will get an audible warning and the Hi V light will blink if there is Voltage Greater that 30V present at the input terminals o In addition to the LED and audible beep the 61 702 and 61 704 has a tactile vibration when voltage is present e NCV When the NCV button is pressed the analog to digital circuit is turned off and the NCV circuit is activated Sensing for the NCV is at the tip of the Clamp Jaw or by the Red Test Lead in the red input terminal Follow the operation instructions giving in the operator s manual for proper use of this function The NCV function is on Ideal Models 61 701 61 702 and 61 704 e CP When the 60Hz AC power is clean with less than
4. 50Hz 190V AC 500Hz 190V AC IkHz V AC 200V V AC 200V Hi gh Model number Limit 1926 61 702 61 704 1926 61 702 61 704 1943 61 702 61 704 192 6 61 700 61 701 61 702 61 704 192 6 61 700 61 701 61 702 61 704 194 3 61 700 61 701 61 702 61 704 V AC 600V 500V AC 500Hz 485 515 61 700 61 701 V AC 750V 700V AC 500Hz 681 719 61 702 61 704 Table 2 DC Voltage Test Function Low High V DC 200mV 190mV 188 9 191 1 61 700 V DC 2000mV 1900mV 1889 1911 61 700 61 702 61 704 V DC 20V 61 701 V DC 200V 190V 188 9 191 1 61 700 61 701 61 702 61 704 V DC 600V 500V 61 700 61 701 V DC 1000V 900V 894 906 61 702 61 704 Table 3 AC Current Test Function Lo High A AC 200A 100A AC 50Hz 103 5 61 700 61 701 61 702 61 704 A AC 200A 100A AC 400Hz 105 5 61 700 61 701 61 702 61 704 Form number TM61700 1 2 4 Rev 4 September 2004 Page 6 Table 4 Capacitance Frequency and Resistance Test Function Low High 5 IKHz 10V 996 1 004 61 700 61 701 Hz auto 10KHz 10V 996 10 04 61 700 61 701 Q 200K 100KQ 98 7 101 3 61 700 61 701 61 702 61 704 Table 5 Diode and Continuity Check Function Low High Range REN limits Limit 500mV DC 485 n3 40Q beep on Continuity 150Q beep off aj 5002 beep on Continuitv 30002 beep off CALIBRATION Calibration Preparation 1 Turn on the calibrator allow calibrator to warm up P
5. range to 2000mV DC 2 Connect the calibrator to the V and COM inputs on the meter 3 Output 1 900 VDC Adjust VRI VR 200Q until unit display reads 1900 De energize source and remove test leads V AC Calibration 61 704 only Refer to Figure 4A 1 Set the function range to the 2000mV AC 2 Connect the calibrator to the V and COM inputs on the meter 3 Output 1 900 VAC 50Hz Adjust VR5 VR 1002 until unit display reads 1900V 1 digit De energize source and remove test leads A AC Calibration 61 700 Refer to Figure 1 61 701 Refer to Figure 2B peel front label back to access calibration hole 61 702 Refer to Figure 3B peel front label back to access calibration hole 61 704 Refer to Figure 4B peel front label back to access calibration hole 1 Set the function range to the 200A AC 2 Set output of the AC calibrator for 10 00A 60Hz 0 01 and connect it to Coil 10N 100 0A AC 3 Clamp the jaws to the coil ION 4 Adjust VR2 VR 2KQ for a display reading of 100 0 1 digit Calibration of the 61 700 series is complete Remove all leads from the calibrator and equipment Return unit to proper operating condition Form number TM61700 1 2 4 Rev 4 September 2004 Page 8 61 701 61 701 61 700 Front Side Back Side Figure 1 Figure 2A Figure 2B WRI 61 702 61 704 61 704 Back Side Front Side Back Side Figure 3A Figure 3B Figure 4A Figure 4B Form number TM61700 1 2 4 Rev 4 September 2004
6. the standard practices for handling static sensitive devices For additional information about IDEAL INDUSTRIES INC and its products and services visit IDEAL INDUSTRIES INC web site at www idealindustries com Precautions and Safety Information Use the meter only as described in the Users Manual If you do not do so the protection provided by the meter may be impaired Read the Safety Information page before servicing this product In this manual a Warning identifies conditions and actions that pose hazard s to the user a Caution identifies conditions and actions that may damage the meter or the test instruments The Symbols The symbols used on the Meter and in this manual are explained in Table A Table A Symbols Symbol Symbol Indicator Lights High Voltage Indicator GANNONAD so NAPORA NCV Non Contact indicator information in manual Danger Risk of electrical Continuity indicator shock Clean power indicator Double Insulation Protection P On if power is Clean Class II Off if power has gt 5 THD CAT IM IEC Over voltage Category p Form number TM61700 1 2 4 Rev 4 September 2004 Page 2 SAFETY Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it To avoid potential hazards use the product only as specified amp CAUTION These statements identify conditions or practices that could result in damage to the equipment or other
7. 5 Total Harmonics Distortion THD on AC voltage the green CP light will be energized If there is greater that 5 THD on the line the green CP light will be de energized Certifications and compliances Safety Designed to IEC 1010 1 UL3111 1 and CSA specifications 1000V DC Category III 61 702 61 704 600V DC Category III 61 700 61 701 750V AC Category III 61 702 61 704 600V AC Category III 61 700 61 701 CAT III Distribution level mains fixed installation Input rating Over voltage category CAT II Local level mains appliances and portable equipment CAT I Signal level special equipment or parts of equipment telecommunication electronics Form number TM61700 1 2 4 Rev 4 September 2004 Page 3 General specifications Characteristics Description Display 3 Digit LCD display Display Count 2000 count maximum reading 1999 Over range Indication OL is displayed Sampling Rate 2 5 time second Operating Environment 0 C to 50 C 32 F to 122 F Relative Humidity 0 75 RH Storage Environment 20 C to 60 C 4 F to 140 F at lt 80 relative humidity Power source 9V Battery NEDA 1604 Battery Live 300 hours typical alkaline 61 700 and 61 701 150 hours typical alkaline 61 702 and 61 704 Low Battery Indicator symbol indicates low battery voltage Auto power off Approximately 60 minutes Dimensions 9 7 H X 3 7 W X 1 8 D 247mm H X 94mm W X 46mm D Maximum Cable S
8. 500Hz 2 0 4 5 digits DC Voltage 2000mV 200V 1000V 0 5 1 digit AC Current 200A 50Hz 60Hz 3 0 4 5 digit 200A 60Hz 400Hz 5 0 5 digit 200MFD 3 0 5 digits 2K 40KHz Auto ranging only Continuity AC Converter Average responding RMS Calibrated to Sine Wave Overload Protection AC and DC Voltage not to exceed 600V DC or VAC RMS for the model 61 700 and 61 701 and 1000V DC or 750V AC for the 61 702 and 61 704 Resistance Not to exceed 500V DC or AC RMS Capacitance Frequency Diode Check Continuity not to exceed 500V DC or VAC RMS Form number TM61700 1 2 4 Rev 4 September 2004 PERFORMANCE VERIFICATIONS Page 5 Perform the following analysis if the meter conforms to the limits listed in Table through 5 the meter is functioning correctly If the meter does not conform to any of the listed limits the calibration procedure must be performed Performance Verification Preparation 1 Turn on the calibrator allow calibrator to warm up Temperature stabilization should be reached after 30 minutes 2 Remove battery cover and using a calibrated meter to ensure the battery measures a minimum of 7 5V DC If the battery measures under 7 5V DC replace the battery before beginning the performance test 3 Input the values listed in Table 1 through 5 Table 1 AC Voltage Test Range Limit V AC 2000mV 1900mV AC 50Hz V AC 2000mV 1900mV AC 500Hz V AC 2000mV 1900mV AC 1kHz V AC 200V 190V AC
9. erform calibration at 23 2 C at relative humidity of lt 70 Temperature stabilization should be reached after 30 minutes 2 Disconnect the test leads and turn the range switch to OFF Remove the screws holding the battery cover and one at the jaw 4 Remove the case bottom using care not to damage the battery connector and leads to the continuity beeper Beeper is attached to the bottom case cover 5 Using a calibrated meter ensure the battery measures a minimum of 7 5V DC If the battery measures under 7 5V DC replace the battery R Calibration Procedure It is recommended that all IDEAL meters undergo the following calibration procedure on an annual basis The class of calibrator or equipment should have an accuracy that exceeds by an expectable ratio the accuracy of this instrument Form number TM61700 1 2 4 Rev 4 September 2004 Page 7 V DC Calibration 61 700 Refer to Figure 1 1 Set the function range to 200mV DC 2 Connect the calibrator to the V and COM inputs on the meter 3 Output 190 0mV DC Adjust VR1 VR 200Q until unit display reads 190 0 De energize source and remove test leads 61 701 Refer to Figure 2A 1 Set the function range to 20V DC 2 Connect the calibrator to the V and COM inputs on the meter 3 Output 19 00V DC Adjust VR1 VR 200Q until unit display reads 19 00 De energize source and remove test leads 61 702 Refer to Figure 3A 61 704 Refer to Figure 4A 1 Setthe function
10. ize ACA 1 32mm Weight Approximately 13 4 oz or 430g including battery RANGES and ACCURACY SPECIFICATION Accuracy Accuracy specifications at 23 C 5 C 73 4 F 9 F less than 75 RH Temperature Coefficient 0 1 times the applicable accuracy specification per degree C from 0 C to 18 C and 28 C to 50 C 32 F to 64 F and 82 F to 122 F Electrical Specification Accuracy are reading plus number of digits at 23 C 5 C lt 75 RH Form number TM61700 1 2 4 Rev 4 September 2004 Page 4 61 700 Function 200V 50Hz 500Hz 1 2 3digits 200V 50Hz 1KHz 2 0 4 5 digits 600V 50Hz 500Hz 2 0 4 5 digits DC Voltage 200mV 2000mV 200V 600V 0 5 1 digit AC Voltage AC Current 200A 50Hz 60Hz 3 0 4 5 digit 200A 60Hz 400Hz 5 0 4 5 digit 2K 40KHz Auto ranging only 0 1 3 digits Resistance 20002 200KQ 1 0 3digit Diode Check 1mA 0 6mA Not specified lt 100Q on Diode ih Continuity Not Specified 61 701 Function AC Voltage 200V 50Hz 500Hz 1 2 3 digits otage 200V 50Hz 1KHz 2 0 5 digits 600V 50Hz 500Hz 2 0 5 digits 200A 60Hz 400Hz 5 0 4 5 digit Resistance 20002 200KQ 1 0 3digit Diode Check 1mA 0 6mA Not specified lt 100Q on Diode Continuity Not specified 61 702 61 704 Function Ranges Accuracy Range 2000mV 200V 50Hz 500Hz 1 2 3digits AC Voltage ae 2000mV 200V 500Hz 1KHz 2 0 4 5 digits 750V 50Hz

Download Pdf Manuals

image

Related Search

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61 700 MODEL: 61 701 MODEL: 61 702 MODEL: 61 704

Related Contents

    SYSDRIVE 3G3XV Inverter 3G3XV- Operation Manual                

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.