1. Vira PowerPlug Disconnect Model 103 Installation Instructions To be sold only with installation instructions AN WARNING This is a current rated device Use in applications involving amperage beyond its rating can be dangerous and cause electrical fires Do not exceed maximum current and voltage levels Instructions Conductor installation 1 Wiring must comply with all applicable electrical codes 2 Turn off power before removing or installing disconnect 3 Strip wires to 3 8 9 5 mm 18 AWG can be 3 8 to 1 2 strip 4 Grip load wires firmly and push conductors into white cap ports see load side diagrams at right for proper wire insertion for ballast configurations 5 Grip supply wires firmly and push conductors into ports opposite load wires See line side diagram at right for proper wiring configuration 6 Use only one conductor per port and assure that no copper is exposed on any of the wires inserted 7 See disconnect de mate mate installation instructions below when replacing ballasts 8 The wire insertion side of this product is listed for ONE TIME USE ONLY DO NOT REMOVE AND REPLACE WIRES AN DANGER NEVER remove wires from product as contact with electricity can cause serious injury or death Shut off power at the circuit breaker or remove fuse when installing this product AN SAFETY NOTICE Improperly installed electrical wiring can be dangerous and cause electrical fires This prod
2. uct must be used in accordance with the current rating and wire sizes listed Consult local building code before doing any electrical work COPPER TO COPPER ONLY Do not use on Aluminum Temperature rating 105 C 221 F maximum Flame Rated UL94V 0 This disconnect is rated for 600 Volts 6 Amps maximum Wire Range Line Side Orange Load Side White Solid 12 18 AWG 18 AWG stranded 12 14 AWG 19 Strand or less stranded Tin Bonded 12 14 AWG 19 Strand or less 18 AWG 16 AWG 26 Strand or less 18 AWG 16 Strand or less 16 Strand or less Disconnect de mate mate installation To de mate grasp disconnect at each end and pull apart to separate the disconnect halves Do NOT pull on wires To mate the disconnect grasp each disconnect half align halves and push together Completed connection should appear as shown Load Side 6 Ports White Cap Line Side 3 Ports Orange Cap Single Ballast 2 Hot Hot 2 _ ae Reo oauiast Neutral Switchable Step Dimming Full Light Output IDEAL INDUSTRIES INC Becker Place Sycamore IL 60178 U S A 800 435 0705 Customer Assistance www idealindustries com ND 6847 4

Download Pdf Manuals

image

Related Search

IDEAL INDUSTRIES INC PowerPlug Luminaire Disconnect Model 103 Instructions Manual

Related Contents

                    

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.