1. inductor including motors transformers and solenoids ean the exterior with clean dry cloth Do not use liquid 8 General Operation Auto power off To extend the life of your battery the meter automatically turns off after approximately 60 minutes Selecting Ranges For all ranges and functions choose a range just above the expected value If display reads OL overrange select a higher range If display shows less than three numbers select a lower range for better resolution Accuracy Specifications Accuracy specifications are based on nominal operating tem perature of 74 F 8 and a relative humidity less than 75 Accuracy is specified as of reading number of least significant digits Lead Storage Silicone test leads are provided with the meter These test leads stay flexible in very cold weather and can withstand high temperatures without melting For convenient lead storage wrap the leads as shown AC Current Range Resolution Max Accuracy Display 200A 0 1A 199 9 3 5 Frequency response 50Hz 60Hz 5 5 60Hz 400Hz True RMS Sensing 61 704 only 6 To Measure AC Current 1 Set the rotary switch to the appropriate AAC range 2 With the jaws closed separate one wire from a bundle using the long fixed jaw 3 Slide the wire to the corner where the two jaws meet then open the jaws to let it in 4 Measure the curren
2. 61 702 fe l 461 704 700 Series 200 Amp Clamp Meters Hv Nev 0 0 O Uo em Hv NOYO cp 1 Non contact voltage NCV 61 702 G With the NCV tab on the tip of the clamp close to an AC TaN CaM VOUIAGE voltage press the NCV button The NCV LED will light and SHAKER the beeper will beep The closer the NCV tab is to AC volt age the louder the beep To differentiate between hot and neutral in an outlet insert the NCV tab into each slot in the outlet The beeper will be much louder on the hot side of the outlet than the neutral 2 The test lead can also be used to differentiate between the hot and neutral Insert the rod test lead into the port and snap it into the test probe holder Press the NCV button and insert the probe into each slot of the outlet The beeper will only beep on the hot side of the outlet Test probe holder Use the single test probe holder to make voltage testing easy Indicator lights HI V High voltage indicator In any VAC VDC range when a voltage greater than 30V is touched the beeper will beep and the red Hi V LED will blink In addition to the LED and beeper the meter will shake when connected to high voltage Even if the LED can t be seen or the beeper can t be heard the shake can be felt NCV Non contact voltage indicator Continuity indicator CP Clean power indicator When the 60Hz AC power is clean the green LED will be on If the
3. into the COM port and the red test lead into the port Set the rotary switch to the appropriate Ohms range For correct reading ensure that the device being tested contains no voltage 5 Measure the resistance ew Range Resolution Max Accuracy Display 200MFD O 1MFD 199 9 3 5 To Measure Capacitance 1 Disconnect the capacitor from power 2 Short the terminals to discharge the capacitor 3 Disconnect any resistors that might be between the termi nals of the capaci tor o acho CAPACITOR 4 Plug the black test lead into the COM port and the red test lead into the port tch to the MFD position eads to the capacitor and measure the 5 Set the rotary swi 6 Connect the test capacitance Diode Check To ensure a proper f voltage across the compone test function allows across diode and tra 1 Turn off power to and discharge al 2 Plug the Black test lead i lead into the port tch to the Bk 1 position eads to the diode Normally th good silicone diode is shown between the diode under test is defective 000 3 Set the rotary swi 4 Connect the test voltage drop of a 400V and 90V capacitors nctioning diode the meter wil t from a test current The diode neasurements of forward voltage drops sistor junctions the device or circuit that is bei to the COM port and t develop a ng tested he Red test e forward
4. ds turn meter off and remove the battery cover Replace th 1064 9V battery Warranty Statement This tester is warranted to the original e battery with a NEDA type purchaser against defects in material and workmanship for two years from the date of purchase During this warranty period will at its option replace or repair the IDEAL INDUSTRIES INC defective unit subject to verification of the defect or malfunction This warranty does not apply to defects resulting from abuse neglect accident unauthorized repair use of the instrument Any implied warranties arising out of t product including bu i chantability and fitness for a particular the above The manufacturer shall not of the instrument or other incidental o alteration or unreasonable he sale of an IDEAL ot limited to implied warranties of mer purpose are limited to be liable for loss of use consequential damages expenses or economic loss or for any claim or claims for such r damage expenses or economic loss State laws vary so the above limitatio apply to you This warranty gives you you may also have other rights which IDEAL INDUSTRIES INC Sycamore IL 60178 U S A 800 304 3578 Customer Assistance www testersandmeters com ND 2356 3 Made in Taiwan s or exclusions may not specific legal rights and vary from state to state
5. meter is connected to AC power and the green LED is not on the circuit has more than 5 2 total harmonic distortion nominal Investigation with special ized equipment may be necessary Sensitivity 20VAC on 200VAC range 90V on 750VAC range Hold button 61 702 Press hold button during measurement to capture the value To clear the held value press the hold button again or press the reset button NCV button Press the NCV button to test for non contact voltage Backlight 61 704 Backlight auto off approximately 60 sec 3 Rotary switch T 2ozvo0o WARNING 1 DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE 2 To avoid electrical shock hazards and or damage to the Ensure meter is in proper working order before using Max button Press Max prior to a measurement to capture the maximum reading displayed during the measurement To clear the max value press the max button again or press the rese button rn the rotary switch to the appropriate function and range for the measurement OM port and port ug the black lead into the com port and the red lead in e port for VAC VDC Frequency Resistance and apacitance measurements and Diode and Continuity hecks RATINGS e Voltage is not to exceed 750VAC or 1000VDC e Resistance function is not to be performed on circuits capable of delivering greater than 600 Volts e Frequency Capacitance and Continuity fu
6. nctions are not to be performed on circuits capable of delivering greater than 500 Volts e Test NCV function on known live wire before using e Do not exceed the voltage ratings for the meter Use caution when measuring voltage e Do not use during electrical storms AC power sources w h ith inductive loads or electrical storms may result in igh voltage High energy transients can damage meter and present a dangerous shock hazard e Turn off power to the circuit or device being measured before taking resistance and capacitance measurements Fully discharge all capacitors before measuring Visually inspect meter for damage Performing a continuity check can verify proper operation If the meter reading goes from overload to zero this typically means the meter is in proper working order 4 4 Visually inspect leads for damage before using Replace if insulation is damaged or leads appear suspect 5 Never ground yourself when taking electrical measurements Do not touch exposed metal pipes outlets fixtures etc Keep your body isolated from ground by using dry cloth ing rubber shoes mats or any other approved insulating naterial Keep your fingers behind the finger guards on the probes Work with others 6 Before beginning all unknown measurements set meter to highest possible range 7 Disconnect the meter from the circuit before turning off any n C
7. short circuit or OL non conductive is displayed 10 Continuity Check To Verify Continuity A continuity test ensures that all circuit connections are intact 1 Plug the Black test lead into the COM port and the Red test lead into the port 2 Set the rotary switch to the BK 1 position 3 Connect the test leads to the circuit to be measured The beeper will sound within 100mS if the resistance of the circuit measured is lower than 300 Ohms 4 In addition to the beeper both 61 702 and 61 704 have an LED to verify continuity General Specifications Display 3 1 2 digit LDC display Polarity Indication Automatic negative indicated positive implied Overrange Indication OL Low Battery Indication E when the battery voltage drops below operating voltage Auto Power Off Approx 60 min Temperature Coefficient 0 1 x specified accuracy F lt 64 F or gt 82 F Power Requirements 9V NEDA 1604 Battery Life 150 hours typical with alkaline 75 hours typical with carbon zinc Installation Category IEC 1010 1 IEC1010 2 032 Cat III 1000V Ws CE Ws Maintenance Warning To avoid electrical shock remove test lead before opening the cover Repairs or servicing not covered in this manual should only be performed by qualified personnel 11 Battery Replacement When the multimeter displays E the battery must be replaced Disconnect and unplug lea
8. t in only one wire at a time AC amp DC Volts AC Voltage Range Resolution Max Accuracy Display 2000mV imV 1999 1 2 3 200V 0 1V 199 9 1 2 3 750V 1V 750 2 5 Frequency response 50Hz 500Hz 2 5 500Hz 1KHz 50Hz 500Hz on 600V and 750V ranges True RMS Sensing 61 704 only DC Voltage Range Resolution Max Accuracy Display 2000mV imV 1999 200V 0 1V 199 9 0 5 1 1000V 1V 1000 To Measure Voltage 5 Plug the black test lead into the COM port and the red test lead into the port 6 Set the rotary switch to appropriate VAC or VDC range 7 Connect the meter in parallel with the load or circuit 8 Measure the voltage OFF 7 Vac 00 a 7 Frequency To Measure Frequency 1 Plug the black test lead into the COM port and the red test lead into the port 2 Set the rotary switch to the HZ position 3 Connect the meter in parallel with the load or circuit 4 Meter is auto ranging and will select 2k 20k or 40k range 5 Measure the frequency Resistance Ohms Capacitance Testing Range Resolution Max Accuracy Display 2002 0 1Q 200 0 1 3 200kQ 0 1kQ 200 0 1 3 To Measure Resistance 1 Turn the power off to the circuit or device that is to be measured and discharge all capacitors before attempting a measurement 2 Plug the black test lead