Home

Agilent ChemStation OpenLAB Option Concepts Guide(1)

image

Contents

1. All actions related to any ECM file are listed here together with the file name date ECM user name who performed the action and a reason provided by the according user You can search the entries for example for a specific date or date range or for entries related to specific categories Files Folders System Scheduler or Instrument Also you can print the entries or export them to a file ChemStation OpenLAB Option Concepts Guide 87 5 Administration Regarding 21 CFR Part 11 Compliance ECM System Log The System Log is a record that shows changes to the system including configuration changes e mail notifications and additions or changes of Locations Cabinets Drawers or Folders You can view file related system administration folder administration or Scheduler related entries For example you can see when a Location was added and by whom The System Log is always active you do not need to enable it To view the ECM System Log 1 In ECM select the Administration page 2 In the navigation pane select the Activity Log gt System Log node All general actions related to ECM are listed here together with the date ECM user name who performed the action and a reason provided by the respective user Depending on the ECM Account administration the reason may be optional or mandatory see Account configuration on page 89 You can search the entries for example for a specific date or date range or for
2. 3 Log on to the ECM Print Services 4 Select the Add Printer icon to add a printer with the following details Type PDF Converter Name Specify a unique name e g Chem1 Print Define the printer security options in accordance with your organization s security policies 5 Click Add to continue Depending on your PC configuration a message regarding the Browse for Folder dialog is shown Exit that message with OK 6 In the upcoming Browse for Folder dialog select the monitor folder for the ECM print service 7 The printer has now been created successfully and is available in the ECM Service dialog 8 Right click the ECM Print Service icon in the task bar and select Configure Printers see Figure 35 on page 138 9 Open the printer configuration by marking your specific printer and select the Configuration tab For details refer to the ECM Print Services online help ECM you need to specify the ECM LCDF data path where the uploaded files will be stored after transfer Settings Transfer specific settings 138 ChemStation OpenLAB Option Concepts Guide Using Print Services in ChemStation 10 Hardcopy Printers It is also possible to get a hardcopy printout Email It is possible to enable e mail notification 10 Click Apply to apply the configuration to the ECM Print Service and leave the dialog box with OK 11 Leave all printer related dialog boxes with OK 12 In ChemStation it is now possible to specify the newly
3. SSIZIP even E STANDARD_11_S 200 SSIZIP File name STANDARD_11_S 2008 08 26 09 20 13 5C SSlzip GE Open f Files of type SC SSlzip M Cancel Figure 12 ECM Desktop Open dialog If the item is checked out it is marked with a blue or red icon see marker 1 blue icon the item has been checked out by you current user red icon the item has been checked out by another ECM user You can load any checked out item However if an item has been checked out by another ECM user the other user must check in the item before you can save it back to ECM ChemStation OpenLAB Option Concepts Guide 65 4 Working With ChemStation OpenLAB Option 66 Data related workflows To check out or check in an item you can use the respective icons available in the ECM Desktop Open dialog see marker 2 You can only check out the latest version of an item In order to see more details regarding the type and version of the available items select the Detail view see Figure 12 on page 65 marker 3 To open an older version of an item select the Open Revisions command from the Open menu see Figure 13 on page 66 This opens the File Versions dialog where all available versions of the item are listed see Figure 14 on page 67 ECM Desktop Open x Look in Test Data aaa amp amp 1to50f5 gt DEMO_SEQUENCE 2008 02 21 SC SSleip fee LC_test 2008 04 15 20 31 53 SC Slzin 53 LIR 2007 1 2007 02 27_13 43 28 se
4. Sa Save Method Data related commands A Load Data es Save Data Save Data As Commands related to the sequence template a Load Sequence Template a Save Sequence Template Commands related to OpenLAB Intelligence Reporter EY Start OpenLAB IR Create OpenLAB IR Report The Cleanup Data command deletes all data or sequence containers from the local file system that exist in ECM as well Make sure you uploaded the latest version to ECM before you confirm this command See Cleanup Data on Shutdown on page 49 With the Manage Queue command you can continue any interrupted data upload to ECM See Manage Queue on Connect on page 49 See ECM Preferences on page 44 for more details on the Preferences dialog See Workflows for Methods and Sequence Templates on page 70 See Data related workflows on page 59 See Workflows for Methods and Sequence Templates on page 70 See Interface Components Concerning OpenLAB IR on page 124 Data Analysis Method and Run Control Data Analysis Method and Run Control Data Analysis Method and Run Control Data Analysis Data Analysis Method and Run Control Data Analysis ChemStation OpenLAB Option Concepts Guide 43 3 Basic Concepts of ChemStation OpenLAB Option ECM Preferences The Preferences dialog contains two tabs that are relevant to ChemStation OpenLAB Option the Transfer Settings tab and the Audit Tr
5. 10 The Agilent Enterprise Content Manager ECM is a web based electronic library that allows you to safely archive and catalog any electronic file ECM allows you to store and index analytical raw data reports and all other types of documents The stored files can be shared with other users You can store any electronic file type such as Microsoft Office documents Adobe PDF documents images and molecular drawings as well as raw data and reports generated by ChemStation ECM allows you to easily collect organize search and review all of your data It automatically extracts searchable metadata from files and provides powerful search capabilities In addition ECM provides embedded viewers for many file types The ECM interface is opened via Microsoft Internet Explorer also referred to as the ECM Web Client ChemStation OpenLAB Option Concepts Guide Introduction 1 Add On Solution for ChemStation OpenLAB Option Starting with revision B 02 01 SR1 Agilent ChemStation provides an interface to the Agilent Enterprise Content Manager ECM which enables you to store analytical data and reports in a secure location From ChemStation you can log in to ECM and store methods sequence templates data files and reports in ECM Data storage can be either automatic that is at the end of a single run or sequence or manual ChemStation data stored in ECM can later be downloaded to ChemStation for review or reprocessing at any time
6. Create and modify the calibration table change calibration settings Run Turn on off the command line View Access to Companion view GC ChemStation only View Access to Method and Run Control view Edit Interactive saving of data to ECM Delete Delete data files in ChemStation Explorer Run Access to Data Analysis view View Access to Diagnosis view Run Enable the ChemStation Full Menu Edit Modify instrument configuration parameters Edit Modify instrument method parameters Edit Modify Integration Events perform Auto Integration Edit Edit options for lon Labels LC MS only Edit Save the current logbook Delete Clear the current logbook ChemStation OpenLAB Option Concepts Guide Appendix 12 Privilege Description CS Manage Transfer Queue CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS Manual Integration Method Method Properties Print Report Recalibration Report Report Layout Report Template Reprocess Retention Time Lock Retention Time Search Sequence Sequence Summary System Suitability Run Access to the following items of the Spooler Queue Manager Save selected item locally Delete selected item e Properties Run Perform manual integration Edit Save method changes includes Update Sequence Master Method in Data Analysis view Delete Delete a method in ChemStation Explorer Edit Modify Run Tim
7. Furthermore ChemStation OpenLAB Option offers features that enable users to comply with 21 CFR Part 11 and similar regulations for electronic records and electronic signatures Mandatory login connection to ECM e Configurable session locking e Configurable ChemStation user roles and privileges e Full data traceability through audit trails for methods and results e Full data versioning ChemStation OpenLAB Option requires the following components e ECM Server e ChemStation OpenLAB Option installed on the ECM Server ECM Web Client installed on the ChemStation computer e ChemStation with ChemStation OpenLAB Option installed on the ChemStation computer e Connection between the ChemStation computer and the ECM Server The main workflows for the transfer of raw data and methods sequence templates are listed below These workflows indicate the system activities in relation to the work processes ChemStation OpenLAB Option Concepts Guide 11 1 12 Introduction Add On Solution for ChemStation OpenLAB Option Overview of data related workflows Wor y Data Acquisition Review Workflow 1 Data Acquisition pF o O After Data Modification Workflow 3 Reprocessing Modifying Upload Worki Reprocessing Import Import after Reprocessing After Reproces sing Data Modification Load Data j aaa Data A Workflow 1 Raw data acquisition and automatic transfer to ECM 1 Analytical raw data
8. server 10 2 0 4 with Oracle client 10 2 0 1 e Ensure that the minimum PC and operating requirements are met for ChemStation Details can be found in the Installing your ChemStation manual for your respective instrument e Setting up the connection from ChemStation to the ECM Server requires the address of the ECM Server 20 ChemStation OpenLAB Option Concepts Guide Installation 2 Compatibility ChemStation Add Ons ChemStation OpenLAB Option is not supported in combination with the following ChemStation Add Ons and features e ChemStore Security Pack e Purify e Easy Access ChemStation Unique Folder Creation OFF item is not accessible ChemStation OpenLAB Option Concepts Guide 21 2 Installation and Configuration Tasks on ECM Server 22 You must execute the database script for ChemStation privileges on the ECM Server to implement ChemStation related users roles and privileges within OpenLAB ECM In addition after installing the program you must take care of several ECM settings Updating the ECM Database A database script is provided on the ChemStation DVD that creates specific ChemStation privileges and ChemStation roles in ECM The procedure depends on the ECM Database type Oracle or SQLServer Prerequisites You need the login data of the following users A Windows user who can connect to the ECM Database e An ECM Database user who is authorized to access the ECM schema and to update the tables
9. written agreement with warranty terms covering the material in this document that conflict with these terms the warranty terms in the sep arate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accor dance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or subcon tract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 June 1995 or as a commercial item as defined in FAR 2 101 a or as Restricted computer soft ware as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract clause Use duplication or dis closure of Software is subject to Agilent Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will receive no greater than Restricted Rights as defined in FAR 52 227 19 c 1 2 June 1987 U S Government users will receive no greater than Limited Rights as defined in FAR 52 227 14 June 1987 or DFAR 252 227 7015 b 2 November 1995 as applicable in any technical data Safety Notices CAUTION A CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly per formed or adhered to could result i
10. 5 Administration Regarding 21 CFR Part 11 Compliance This chapter explains the purpose of 21 CFR Part 11 and its implementation in ChemStation with ChemStation OpenLAB Option 6 Custom Fields This chapter explains the purpose and usage of custom fields in ChemStation ChemStation OpenLAB Option Concepts Guide 3 In This Guide 7 Treatment of ChemStation Legacy Data and Data Migrated from ChemStore This chapter provides information on migrating legacy ChemStation sequence data to sequence container format in order to be able to upload these data sets to ECM 8 Interface to OpenLab Intelligence Reporter This chapter provides information on the integration of OpenLAB Intelligence Reporter in Agilent ChemStation 9 Attribute Extraction Services for ChemStation Data This chapter provides an overview of the available ECM Attribute Extraction Services AES for ChemStation data The AES extract metadata information from the ChemStation data files These metadata make the ChemStation data searchable For detailed information refer to the ECM documentation 10 Using Print Services in ChemStation This chapter gives a brief overview of how to install and configure the Print Services This enables you to automatically upload ChemStation reports to ECM in a PDF format 11 Troubleshooting The chapter gives some elementary troubleshooting hints 12 Appendix ChemStation OpenLAB Option Concepts Guide Contents Introduction
11. Delete Add Run CS Sequence X X CS Sequence Summary X CS System Suitability X CS Transfer Preferences X CS Tune X CS Verification X Table6 Default CS Operator privileges Privilege View Edit Delete Add Run CS Control X CS Data X CS Print Report X CS Run X CS Sequence X CS Sequence Summary X ChemStation OpenLAB Option Concepts Guide Appendix 12 ECM related privileges concerning the ChemStation configuration The privileges described in the following table must be assigned to at least one of your roles in order to become active Table 7 List of ECM related privileges Privilege View Edit Delete Add Run Description Content File X X e Minimum privilege for ChemStation to access ECM Privileges to view ECM Properties in ChemStation Content File Filtering X e Minimum privilege for ChemStation to access ECM e Privilege to add files manually to an ECM folder Content File Revisions X e Privilege to view revisions in ChemStation Content File Type XLS X X Privilege to add and check in files with an xls extension Content Folder X X X e Minimum privilege for ChemStation to access ECM Privilege to view ECM Properties in ChemStation Content Folder Access X e Privilege to view and change any Properties folder property tab Content Rekey File X Privilege to rekey files in ECM e g with XML Filters System Advanced Search X e Privilege to use the Advanced Search
12. LCDF path of the sequence container is shown in the ChemStation toolbar ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB Option 4 The color of the Sequence Data icon in the Navigation Pane allows to track the modification status of the data lt The sequence container is stored in ECM and has not been modified locally 9 The sequence container is stored in ECM and has been modified locally The upload process may take some time when large amounts of data are uploaded During this time ChemStation is busy and the user cannot perform tasks in ChemStation Please wait until the upload is completed ChemStation OpenLAB Option Concepts Guide 61 4 Working With ChemStation OpenLAB Option Workflow 2 Offline review during acquisition Workflow 2 Data Acquisition Review After Data Modificatio Figure 10 Offline review during acquisition The workflow Offline revision during acquisition see Figure 10 on page 62 illustrates how raw data is reviewed while the acquisition is still running Directly after the acquisition is finished the original raw data is automatically uploaded to ECM After the review the changed data is again uploaded to ECM When the data is uploaded the second time a new version is created 62 ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB Option 4 To save data to ECM automatically after changing the data 1 Log in to ECM in an online ChemStat
13. Microsoft NET Framework 29 minimum password length 90 monitor folder 138 non privately locked 40 0 open system 81 OpenLAB Intelligence Reporter 116 OpenLAB Option 11 operator 39 OQ PV view 42 Oracle 22 P Part11 17 80 password 39 91 path 16 44 46 PDF format 135 PDF XChange 29 160 preferences 44 prerequisites OpenLABIR 118 OpenLAB Option 20 print management system 136 print services 136 privately locked 40 privilege 25 26 95 Purify 21 Q quick search 128 Reader role 26 registration packet 30 registration 30 remote data path 16 45 remote datapath 44 report template 124 report examples 119 report history 86 reporttxt 133 reporter client 124 report 123 reporting 105 require entry in reason field 90 result xml 132 results audit trail 85 role 24 25 26 90 91 run log 85 S save method 75 search expression 129 search types 128 sequence container 56 server not available 144 server software 20 server URL 39 session lock 40 94 signature screen timeout 96 software certificate 30 spooler queue manager 50 SOLCmd 23 SOLPlus 22 SQLServer 23 ssizip 56 58 Start OpenLABIR 125 system administrator email 90 system log 88 T time based lock 40 time based lock 94 timeout 90 96 token 46 transfer settings 44 47 U unattended mode 139 141 unauthorized access 38 uninstallation 36 update methods 42 update sequences 42 URL 39 user interface OpenLABIR 124 OpenLA
14. Name Instrument Number Operator Automatic Data Transfer Settings In the Preferences dialog View gt Preferences the ECM tab allows you to specify the automatic settings for the transfer of raw data The transfer settings as well as the Remote Data Path are used to automatically upload data to ECM If you are not logged in to ECM in ChemStation the data cannot be automatically uploaded to ECM as specified in the transfer settings The data is then queued in the Spooler Queue Manager see Spooler Queue Manager on page 50 If you perform data acquisition from the Diagnosis view or 00 PV view the transfer settings are ignored The analytical raw data is written to the ChemStation data file system as predefined in the diagnosis or verification methods After Acquisition If you select this check box the data is automatically uploaded to ECM after an acquisition The raw data files are written to the local ChemStation file system while the sequence is still running When the complete sequence is finished the raw data files are compressed to an SSIZip file which is then uploaded to ECM For more information please refer to Workflow 1 Acquisition and automatic upload on page 59 ChemStation OpenLAB Option Concepts Guide 47 3 48 Basic Concepts of ChemStation OpenLAB Option After Any Data Modification If you select this check box the sequence data container is automatically uploaded to ECM after you change
15. OpenLAB Option Concepts Guide Introduction 1 21 CFR Part 11 Compliance Effective August 20 1997 the U S Food and Drug Administration FDA released and published a new rule to enable pharmaceutical companies to approve their results with electronic signatures and to transfer paper trail documentation into electronic records This rule is known as 21 Code of Federal Regulations Part 11 referred to as 21 CFR Part 11 and applies to all industry segments regulated by the FDA 21 CFR Part 11 includes the US Federal guidelines for storing and protecting electronic records and applying electronic signatures The intent of these guidelines is to ensure that electronic records subject to these guidelines are reliable authentic and maintained with high integrity ChemStation OpenLAB Option with ChemStation B 04 xx provides the necessary controls for managing system access audit trail functions versioning of ChemStation data and electronic signature functions Agilent OpenLAB ECM ensures secure record keeping and data archival Agilent OpenLAB ECM is proven and has been deployed at many leading life sciences companies to satisfy compliance mandates for 21 CFR Part 11 ChemStation OpenLAB Option Concepts Guide 17 1 Introduction 21 CFR Part 11 Compliance 18 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB Option Concepts Guide e ee 2 e Installation J Prerequisites 20 Compatibility 21 Installation and C
16. Path is not set or is incomplete Probable cause Suggested actions 1 The Remote Data Path is not set or is Make sure that the information on ECM Server incomplete ECM Account and a complete LCDF path is provided in the Transfer Settings ECM gt Preferences gt Transfer Settings ChemStation OpenLAB Option Concepts Guide 145 11 Troubleshooting Error Messages in the Spooler Queue Manager Account Mismatch Probable cause Suggested actions 1 Account setting in Preferences differs from Correct the Transfer Settings and connect to current connection or offline ECM Host Mismatch Probable cause Suggested actions 1 ECM Server in Preferences differs from Correct the Transfer Settings and connect to current connection or offline ECM The queue already contains items Probable cause Suggested actions 1 There are items in the queue that have been Process queue in the correct order If necessary queued before the current item export items that can t be resolved Invalid license ID or license has expired Probable cause Suggested actions 1 Server license timeout Log out and log in again 146 ChemStation OpenLAB Option Concepts Guide Troubleshooting 11 You do not have permission to create a new Drawer Folder Probable cause Suggested actions 1 You do not have appropriate privileges to Ask an administrator to give you the create the Drawer or Folder corresponding privileges or to create the needed directorie
17. Remote Data Path you need to select a Location and Cabinet available in the ECM Browser Click Select Path to select the required path in an ECM Explorer dialog For the Drawer and Folder you can either keep the selected items or you can select predefined tokens for an automatic path creation When you use the predefined tokens in the Remote Data Path the system automatically creates the items if they do not already exist in ECM If you use tokens make sure you have the required ECM privileges to create folders Alternatively another user who has the required privileges can create the necessary folders in advance ChemStation OpenLAB Option Concepts Guide 55 3 Basic Concepts of ChemStation OpenLAB Option Compressed ChemStation File Formats When ChemStation data is uploaded to ECM the data is automatically packaged into an SSIzip file Depending on the type of data different packaging formats are used ChemStation data Packaging format Icon in ChemStation Single Runs D SSIZIP d file ACO m and DA M lal Sequence Container SC SSIZIP amp The sequence container contains recursively the whole sequence data stored in the sequence subdirectory all d files along with ACO m and DA M all methods m used during acquisition batch file b sequence logbook file log Methods M SSIZIP w Sequence templates Sor A S SSIZIP io The packaging of ChemStation items is part of ChemStation OpenLAB Option and
18. acquisition yes Automatic transfer after reprocessing yes Automatic import after reprocessing no Calculate peak performance no Automatic transfer after any data modification yes The following details are available LCDF Operator Automatic transfer after acquisition Automatic transfer after reprocessing Automatic transfer after any data modification Automatic import after reprocessing Calculate peak performance The ECM menu The ECM menu and its commands depend on the view that is currently active See the following table for details There is no ECM menu in the Report Layout Verification 00 PV or Diagnosis view Command Description Available in ChemStation views User related commands Biog In Eloy out Change User Brtock Session Update commands Update Methods Update Sequences Templates See User Permissions on page 38 and Session lock on page 40 Update all methods sequence templates that are stored in the local file system with the current version from ECM if existing in ECM Local changes are overwritten Method and Run Control Data Analysis Method and Run Control 42 ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option 3 Command Description Available in ChemStation views Cleanup Data Manage Queue lad Preferences Method related commands ey Load Method
19. cannot be changed manually The packaging is automatically carried out when the data is uploaded to ECM When the SSIZIP files are downloaded from ECM to ChemStation they are automatically unpacked into the according directory in the ChemStation Explorer 56 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB Option Concepts Guide 4 Working With ChemStation OpenLAB Option Transferring Data to or from ECM 58 Data related workflows 59 Workflow 1 Acquisition and automatic upload 59 Workflow 2 Offline review during acquisition 62 Workflow 3 Reprocessing data and automatic upload 64 Workflow 4 Import after reprocessing 68 Workflows for Methods and Sequence Templates 70 Workflow 1 Local files Save new method 70 Workflow 2 ECM Save changed method 72 Updating the Local Master Method or Sequence Template 76 This chapter describes the basic workflows with ChemStation OpenLAB Option There are four data related workflows and two workflows for methods and sequence templates ee Agilent Technologies 57 4 Working With ChemStation OpenLAB Option Transferring Data to or from ECM 58 ChemStation OpenLAB Option provides the ability to open and save different ChemStation items into their ChemStation contexts e Methods e Sequence templates e Single run data e Sequence data All of this data is stored in ECM as SSIZIP containers see Compressed ChemStation File Formats on page 56 When the data
20. complex tests e Decision based result presentation flag outliers automatically sort results by pass fail criteria etc e Search based report content selection e Condense information by visualizing key results e g in trend charts In addition interactive reports can be based upon specific parameters such as a date range or the reports can contain expandable detail information See the following figures as an example ChemStation OpenLAB Option Concepts Guide 119 8 Interface to OpenLab Intelligence Reporter Introduction Sequence Summary Report ChemStation Xi Agilent Technologies Report Creation Date 5 2 2008 5 08 30 PM Sequence Name LIR 2008 1 2007 02 28_14 25 40 Rev 1 Location WAD_Location Laboratory 2 DatalLIR Data Sequence Description Third Sequence for Agilent OL Reporting Acquired by R Honsberg Acq Date 2 28 2007 3 42 40 PM Reprocessed by R Honsberg Rep Date 3 1 2007 9 08 04 AM Acq Instrument AT1200 Solvent 228 2007 1 26 00 PM MHI SS Resolution pss tort SSRSD1 Corso P1 F 02 2282007 1 e 176 0301 O No 228 2007 206 27 PMIXSR_MDAM i gt proowro 252 oss _ osise 1 57 206 58 999922 1 43 __o67 osor 1 57 206 sal 10000276 1 43 20627 998 9758 143 oss o7sca 1 57 206 33 999 4256 1 43 Figure 30 Multi sequence summary report 1 Report header with company logo 2 Sequence information 3 Sequence table 4 Results for calibration s
21. configured printer in the File pull down menu under Printer set up It is possible to select the ECM Print Service as specific printer if the printer has been marked as default printer in the Windows Settings it will be already defined as default printer in ChemStation To set the printer to unattended mode Typically when you print to an ECM Print Service a dialog box asks you to confirm the upload location in ECM as well as some other settings for each report If you are planning to print a whole sequence of reports you can confirm these settings once for the series and than run the printer in unattended mode for a specified time The duration of the unattended mode is set in the Configuration of the ECM Print Service during setup but can be modified at any time 1 Right click the toolbar icon ECM Print Service and select Login Printer Unattended Login Printer Unatt Logout Configuration User Stefan Meyer BUILT IN admin pe a SBS 3 30 Pm Figure 36 Define Logon for Print Service 2 Select the printer that you want to operate in unattended mode 3 Confirm the job settings once and click OK ChemStation OpenLAB Option Concepts Guide 139 10 Using Print Services in ChemStation Configuring ECM Print Services Adobe Distiller 140 F oO Create a monitor folder on your ChemStation computer The folder should not be placed in the Chem32 directory Select the Add Printer icon to add a printer with the detai
22. default settings On the upcoming Adobe PDF Settings dialog deselect optimize for fast Web View and save the settings 7 Exit all printer related dialog boxes with OK 8 In ChemStation it is now possible to specify the newly configured printer in the File pull down menu under Printer set up It is possible to select the ECM Print Service as specific printer if the printer has been marked as default printer in the Windows Settings it will be already defined as default printer in ChemStation To set the printer to unattended mode Typically when you print to a Print Service a dialog box asks you to confirm the upload location in ECM as well as some other settings for each report If you are planning to print a whole sequence of reports you can confirm these settings once for the series and than run the printer in unattended mode for a specified time The duration of the unattended mode is set in the configuration of the ECM Print Service during setup but can be modified at any time 1 Right click the ECM Print Services toolbar icon and select Login Printer Unattended see Figure 36 on page 139 2 Select the printer that you want to operate in unattended mode 3 Confirm the job settings once and click OK ChemStation OpenLAB Option Concepts Guide 141 10 Using Print Services in ChemStation Working with ECM Print Services in ChemStation When you use the ECM Print Service in ChemStation any report printed using the Print
23. file name and status The electronic signature itself is shown in the file properties in the eSig tab and it is also part of the ECM Audit Trail To adjust the user preferences 1 2 3 4 5 In ECM select the Administration page In the navigation pane select the Account Administration node Double click the User Preferences item Click Modify to modify the column settings Select of signatures and click gt to add this property to the selected columns Click OK The number of e signatures is then shown on every content page in ECM ChemStation OpenLAB Option Concepts Guide 97 5 Administration Regarding 21 CFR Part 11 Compliance Electronic Signature 98 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB Option Concepts Guide 6 Custom Fields About Custom Fields 100 Setting Up Custom Fields 101 To define new custom fields 101 To import custom fields from an existing method 102 Specifying Custom Fields Values 103 To provide sample custom fields values 103 To provide compound custom fields values 104 Reporting of Custom Fields 105 To display custom fields in ChemStation reports 105 Reprocessing with Custom Fields 107 This chapter explains the purpose and usage of custom fields in ChemStation ee Agilent Technologies 99 Custom Fields About Custom Fields 100 ChemStation provides numerous fields in which you can enter information on a sequence specific samples or the expe
24. has SQLCmd installed 2 Insert the ChemStation DVD in your CD ROM drive Navigate to the folder EMC DatabaseScript SOLServer 3 If you have the password for the database user SA execute InstallSOL cmd Otherwise execute InstallSOLNonSA cmd A command window opens 4 You are prompted to enter several parameters Type in the required data and press Enter to confirm each entry ECM Database Server Server name of the ECM Database Server ECM Database Name Database User Name Normally CYBERLABLOGIN Directory and Name for log file An installation log file is created in the given location 5 Review the data If something is wrong press Ctrl C to abort the installation ChemStation OpenLAB Option Concepts Guide 23 2 24 6 If everything is OK Enter the password for the database user you provided before The installation begins When the installation is finished the text Installation finished is shown in the command window 7 Press any key to close the command window 8 Check the installation log file It should only include messages about changing the database no warnings or errors Updating roles in existing ECM Accounts When updating the ECM Database certain specific ChemStation roles and privileges have been created If you create a new ECM Account these roles their privileges are automatically available in that new account However if you want to use ChemStation OpenLAB Option with an existing ECM Accoun
25. how raw data is uploaded to ECM directly after the acquisition is finished The raw data is initially stored locally After completing the acquisition the data is automatically uploaded to ECM To save data to ECM automatically after completion of a single run or sequence 1 2 wow ao ol 60 Log in to ECM in an online ChemStation Load a sequence template Your ECM user name is automatically inserted as operator name into the sequence template In the Data Analysis view click View gt Preferences On the Transfer Settings tab configure the following settings Remote Data Path Select the ECM location that you want to use for the sequence data upload Select the After Acquisition check box Configure the sequence parameters and the sequence table Start the acquisition While the acquisition is running the raw data method definition and a copy of the sequence template are locally stored on the ChemStation computer After the sequence is finished all data is automatically uploaded as an SC SSIZIP file to ECM to the previously defined LCDF path The local copy of the data remains on the ChemStation computer The file name of the sequence container is determined by the settings in the sequence template for more details on the sequence template settings refer to the manual Understanding Your ChemStation After uploading the sequence container the sequence icon in the ChemStation Navigation Pane changes from to The
26. in ChemStation System Audit Trail X Privilege to view ECM Properties in ChemStation ChemStation OpenLAB Option Concepts Guide 157 12 Appendix Table 7 List of ECM related privileges Privilege View Run Description System Filtering X Privilege to view or change the Configuration filtering configuration e Privilege to use attribute extraction services and to manage user defined attributes System indexing X Minimum privilege for ChemStation Configuration to access ECM Privilege to view ECM Properties in ChemStation System Quick Search X e Privilege to use Quick Search in ChemStation System Super Object X e Privilege is mandatory for OLIR System Project X e Privilege to view projects in OLIR System Project Access X Privilege to access projects in OLIR 158 ChemStation OpenLAB Option Concepts Guide Index Index 2 checkout status 65 73 ECM web client 11 21 CFR Part 1117 80 ChemStation administration tool 31 ECM web client 16 28 ChemStation administration tool 33 92 ECM account 24 45 A ChemStation operator 39 ECM audit trail 86 ChemStation filter 128 ECM database 22 AGAME Nitar da ChemStore 21 ECM menu 42 AGAME NI cleanup data 43 49 ECM server 45 AS a closed system 81 ECM unavailable account gonfigurationi B9 configuration steps for part 11 83 start ChemStation 93 account 24 39 89 ae a consecutive signature timeout 96 ECM versions 20 aptly log cas Contributor role 91 EC 10 Add Fi
27. in this schema To update an Oracle ECM Database 1 Log on to a Windows computer that has SQLPlus installed 2 Insert the ChemStation DVD in your DVD drive Navigate to the folder ECM DatabaseScript Oracle 3 Ifyou have the password for the database user SYS execute InstallOracle cmd Otherwise execute InstallOracleNonSYS cmd A command window opens 4 You are prompted to enter several parameters Type in the required data and press Enter to confirm each entry Database name host string The host string for your ECM Database User name A user name is only requested if you executed InstallOracleNonSYS cmd ChemStation OpenLAB Option Concepts Guide Installation 2 Path and filename of the log file An installation log file is created in the given location Password for database user The password is not shown while typing Schema user name for ECM Directories where the data files index files and map files of the new database schema should be stored 5 Review the data If something is wrong press Ctrl C to abort the installation 6 If everything is OK Press Enter The installation begins When the installation is finished the text Installation finished is shown in the command window 7 Press any key to close the command window Check the installation log file It should only include messages about changing the database no warnings or errors To update an SQLServer ECM Database 1 Log on to a client that
28. is acquired using ChemStation 2 The raw data is automatically uploaded to ECM using the configured path definitions immediately after the single run sequence is finished 3 A new ECM data set is created in the defined ECM location ChemStation OpenLAB Option Concepts Guide Introduction 1 Workflow 2 Offline revision during acquisition 1 Analytical raw data is acquired using ChemStation 2 While the acquisition is still running part of the data is changed using an offline ChemStation 3 The raw data is automatically uploaded to ECM using the configured path definitions immediately after the single run sequence is finished A new ECM data set is created in the defined ECM location 4 After work in the offline ChemStation is finished the changed data is also automatically uploaded to ECM Another new version of the ECM data set is created Workflow 3 Reprocessing data and automatic upload to ECM 1 Existing analytical data is loaded from ECM into ChemStation 2 The data is reprocessed in ChemStation 3 The data is automatically uploaded to ECM The location in ECM is defined by the original path definitions of the downloaded ECM data 4 Anew version of the data is created in ECM Workflow 4 Import after reprocessing Existing analytical data is opened locally 2 The data is reprocessed in ChemStation After reprocessing the data is automatically uploaded to ECM The location in ECM is defined by the current prefe
29. it is possible to define a search expression by combining two or more of the available keys using boolean operators For detailed information regarding the use of the ChemStation OpenLAB Option Concepts Guide 129 9 Attribute Extraction Services for ChemStation Data Attribute Extraction Services for ChemStation Data various search algorithms refer to the online help of your ECM system or the Enterprise Content Manager Administrator s Guide as well as the AES related manuals 130 ChemStation OpenLAB Option Concepts Guide Attribute Extraction Services for ChemStation Data 9 ACAML Filter The ACAML Filter extracts information from the ACAML files that are also used for the OpenLAB Intelligence Reporter see Interface to OpenLab Intelligence Reporter on page 115 The ACAML files are always created when acquiring or reprocessing data when the OpenLAB Option is installed Please note that the ACAML filter is only available for ECM 3 3 2 SP1 ChemStation OpenLAB Option Concepts Guide 131 9 Attribute Extraction Services for ChemStation Data ChemStation XML Attribute Extraction Service 132 The AES for ChemStation XML extracts key information from the following categories of the result xml generated by ChemStation Rev A revision A 10 02 and later and ChemStation Rev B revision B 01 01 and later per data file Note that ChemStation must be configured to generate the result xml file see the ChemStation XML Connectivi
30. not overwritten To change the settings for all ChemStation instances 1 Select the option Use these settings for all instances on this computer 2 Select the required check boxes The settings are the same as in the Preferences dialog see ECM Preferences on page 44 3 Click OK 94 ChemStation OpenLAB Option Concepts Guide Administration Regarding 21 CFR Part 11 Compliance 5 Electronic Signature Electronic signatures provide a means to sign documents as equally binding as a handwritten signature In addition electronic signatures are reproducible because they are recorded in a secure time stamped audit trail Manipulation is prevented by enabling only users with specific privileges to sign electronically An electronic signature contains the user name full name date and time when the signature was applied the location where the signing occurred and a user configurable definition associated with the signature The signature is always related to the complete SSIZIP container not to a single file inside the container CFR 21 Part 11 requires that companies especially ones that employ any type of approval process use electronic signatures With the help of the Agilent OpenLAB Business Process Manager BPM module you can create highly automated review or approval processes including e mail notification Preparation Privileges An ECM user needs to have the privilege Content File Signatures in order to be able
31. path in ECM The file name of the sequence container is determined by the settings in the sequence template for more details about the sequence template settings refer to the manual Understanding Your ChemStation The sequence icon in the ChemStation Navigation Pane changes from Gi to ae The local copy of the reprocessed data remains on the local file system of the ChemStation computer ChemStation OpenLAB Option Concepts Guide 69 4 Working With ChemStation OpenLAB Option Workflows for Methods and Sequence Templates Workflow 1 Local files Save new method Workflow 1 Local Files Save new method Method A Method A Figure 16 Local files Save new method 70 ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB Option 4 The workflow Local files Save new method see Figure 16 on page 70 illustrates how newly created or locally stored methods or sequence template can be manually uploaded to ECM To upload a new method or sequence template 1 Log in to ECM in an offline ChemStation 2 In ChemStation load the method sequence template or create a new one 3 In the Method and Run Control view click ECM gt Save Method or ECM gt Save Sequence Template respectively The ECM Save dialog opens 4 Navigate to the Remote Data Path of your choice to upload the method sequence template You can only upload items into a Folder not into a Location Cabinet or Drawer 5 If necessary
32. path or Remote Data Path of the storage location Data is stored at Folder level only The ECM program s content structure is similar to rooms filled with file cabinets Each cabinet has multiple drawers which then contain hanging folders Finally paper files are stored in the folders The LCDF structure can be created using the ECM Web Client In addition it is possible to create additional Locations Cabinets Drawers and Folders using the ChemStation Remote Data Path In ChemStation it is also possible to set predefined tokens for the Drawers and Folders In the ECM tree view locations are denoted by a house icon Inside each Location Cabinets are denoted by the file cabinet icon Inside each Cabinet Drawers are denoted by the drawer icon Finally inside each Drawer Folders are denoted by the folder icon The entire content structure appears in the Content book Ei Agilent Technologies Action View Favorites Help Logoff Enterprise S E Content fa DEMO_SEQUENCE 2006 02 24 1 SC SSlzip C ti amp Documentation ocation m e Laboratory 1 E e Laboratory 2 m BTX Cabinet a Pak 7 B A Instrument 1 Drawer Folder 3 Fy Business Process Management 2 Search Results Figure 1 LCDF structure in ECM Uploaded objects can be stored in the lowest i e Folder level only It is not possible to upload data to other levels of the hierarchy ChemStation
33. queue Table 2 Queue management toolbar Icon Tooltip Description ud Process queue Continue processing the transfer jobs As long as there is no error all pending transfer jobs will be processed in the order as they are shown in the list This function is only active if you select the first line in the list Stop processing Stop processing the transfer jobs Save selected item Save the selected lines to a file locally Only the displayed error description and dates are saved to the file The respective data is not included xX Delete selected item Delete the selected transfer job from the queue The concerned data will not be transferred to ECM Ek Properties Display the Queue Management dialog box which shows details 2 of the items in the queue in either summary or detailed form Refresh view Update the display of the items in the list When items are selected from the queue or saved to the local disk an audit trail entry will be added to Audit Trail of ECM ChemStation OpenLAB Option Concepts Guide 51 3 52 Basic Concepts of ChemStation OpenLAB Option When items are deleted from the queue or saved to the local disk they have not yet been uploaded to ECM Queue Management Details Dialog Box The Queue Management Details dialog box is displayed when you click the g tool in the toolbar of the Queue Management dialog box It shows the command specific details of the commands in the Queue Manageme
34. save the item using a different name the original name is used by default but you can modify the name 6 Click Save The Add File dialog opens 7 Enter a reason for the upload and click OK The reason is then shown in the ECM Audit Trail see ECM Audit Trail on page 86 The progress of the upload is displayed in a window until the item is uploaded to ECM After finishing the upload the SSIZIP file is available in ECM as version 1 The file is saved to the Remote Data Path defined in the Preferences see Remote Data Path on page 45 The method icon in the ChemStation Navigation Pane changes from w to w The icon for a sequence template changes from ab to D accordingly ChemStation OpenLAB Option Concepts Guide 71 4 Working With ChemStation OpenLAB Option Workflows for Methods and Sequence Templates Workflow 2 ECM Save changed method Workflow 2 ECM Save changed method Method A c Figure 17 ECM Save changed method The workflow ECM Save changed method see Figure 17 on page 72 illustrates how methods or sequence templates that are already stored in ECM are edited and saved under the same name as a new version 1 Log in to ECM in ChemStation 2 Load a method or sequence template 72 ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB Option 4 Open a method sequence template from your local PC Choose a method sequence template that has been uploaded t
35. ssieip E LIR 2007 2 2007 02 28_09 54 30 se ssizip E LIR 2008 1 2007 02 28_ 14 25 40 se ssizip File name LC_test 2008 04 15 20 31 53 SC SSlzip Ge Open Files of type SC SSlzip pol Revisi lt a _ pen Revisions i Open As Checked Out Open With Original Program Figure 13 Open Revisions command ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB 4 Data related w File Versions Filename LC_test 2008 04 15 20 31 53 S5C SSlzip Last Modified Date 8 22 2008 10 52 37 AM GMT 02 KLEMM JOHANNA AGI 4 15 2008 8 44 32 PM GMT 02 00 Administrator BUILTAN a Figure 14 File versions dialog Select Open in either dialog to download the item to ChemStation If the item was not already checked out it is automatically checked out of ECM when you load it to ChemStation The LCDF path of the data is shown in the ChemStation toolbar 4 In the Data Analysis view click View gt Preferences 5 On the Transfer Settings tab configure the following settings ChemStation OpenLAB Option Concepts Guide e Select the After Reprocessing check box Select the After Any Data Modification check box Modify or reprocess the sequence data After the reprocessing is finished the sequence data is uploaded with its original name to its original LCDF path The version number is increased by one The local copy of the reprocessed data remains on the local file system of the
36. 1 5047867 Standard L1 1 09 05 0 419 0 7917 1 4861453 Average 089 05 0 423 0 8173 14919988 Std Deviation 0 01 0 0 009 0 0235 0 0137213 LIR 2008 1 2007 02 28 14 25 40 Overall Average 089 05 0416 08124 14794036 Std Deviation 0 02 0 0 012 0 016 0 0183484 Min osa 05 0 395 0 7917 1 4398642 Max 092 06 0 436 0 8487 1 5047867 N 12 12 12 12 12 Figure 32 Cross sequence statistics with trend chart 1 Expandable detail information on each sequence 2 Overall statistics 3 Trend chart 122 ChemStation OpenLAB Option Concepts Guide Interface to OpenLab Intelligence Reporter 8 To create a Single Sequence OpenLAB Summary Report 1 Prepare the data in ChemStation There are different ways of preparing the data see Data related workflows on page 59 For example runa sequence with the Transfer Setting After Acquisition Make sure the data has been uploaded to ECM 2 In the Data Analysis view load the relevant data set 3 Under Sequence gt Sequence Output select a suitable OpenLAB IR template 4 Select ECM gt Create OpenLAB Intelligence Report The resulting OpenLAB IR report is opened with the data of the current sequence ChemStation OpenLAB Option Concepts Guide 123 Interface to OpenLab Intelligence Reporter Interface Components Concerning OpenLAB IR 124 If OpenLAB Intelligence Reporter is installed several new interface components are available in ChemStation These components a
37. 40 OpenLAB Option User Interface in ChemStation 41 Overview of new interface elements 41 The ECM menu 42 ECM Preferences 44 Remote Data Path 45 Automatic Data Transfer Settings 47 Transfer Management Settings 49 Spooler Queue Manager 50 Remote Data Path as Sequence Parameters 54 Compressed ChemStation File Formats 56 This chapter describes how to log in to ECM in ChemStation and explains the ECM related user interface items and toolbars as well as the main preference settings ee Agilent Technologies 37 3 Basic Concepts of ChemStation OpenLAB Option User Permissions 38 Log In Log Out To prevent unauthorized access to ECM or unauthorized use of ChemStation OpenLAB Option ECM requires authentication with a user name and password In addition each user needs user privileges defining the accessible content The user administration is set up and managed on the ECM Server For more details about login and user setup refer to the ECM User Administrator s Guide Optional or mandatory Depending on the configuration during the installation of ChemStation the ECM login can be optional or mandatory If it is mandatory you must log in to ECM during the ChemStation startup If it is optional you can initially skip the login and then log in to ECM later If you are already logged in to ECM server in the online instrument session and start the offline session via the item Reprocessing Copy from the View menu the user w
38. 9 WhatisECM 10 Add On Solution for ChemStation OpenLAB Option 11 Data Storage in ECM 16 21 CFR Part 11 Compliance 17 Installation 19 Prerequisites 20 Compatibility 21 Installation and Configuration Tasks on ECM Server 22 Installation Tasks on the ChemStation Computer 27 Uninstallation 36 Basic Concepts of ChemStation OpenLAB Option 37 User Permissions 38 OpenLAB Option User Interface in ChemStation 41 ECM Preferences 44 Remote Data Path as Sequence Parameters 54 Compressed ChemStation File Formats 56 Working With ChemStation OpenLAB Option 57 Transferring Data to or from ECM 58 Data related workflows 59 Workflows for Methods and Sequence Templates 70 Administration Regarding 21 CFR Part11 Compliance 79 Introduction to 21 CFRPart11 80 Overview of Configuration Steps Required for Part11 83 Audit Trails and Logbooks 84 Administration in ECM 89 Administration of ChemStation Settings 92 Electronic Signature 95 ChemStation OpenLAB Option Concepts Guide Contents Contents 6 Custom Fields 99 About Custom Fields 100 Setting Up Custom Fields 101 Specifying Custom Fields Values 103 Reporting of Custom Fields 105 Reprocessing with Custom Fields 107 7 Treatment of ChemStation Legacy Data and Data Migrated from ChemStore 109 Introduction 110 Sequence Container Migration 111 Conversion of Data Migrated from ChemStore 113 8 Interface to OpenLab Intelligence Reporter 115 Introduction 116 Interface Co
39. Agilent ChemStation OpenLAB Option Concepts Guide ot Agilent Technologies Notices Agilent Technologies Inc 2008 2009 2010 No part of this manual may be reproduced in any form or by any means including elec tronic storage and retrieval or translation into a foreign language without prior agree ment and written consent from Agilent Technologies Inc as governed by United States and international copyright laws Manual Part Number G2170 90036 Edition 04 2010 Printed in Germany Agilent Technologies Hewlett Packard Strasse 8 76337 Waldbronn Software Revision This guide is valid for revision B 04 02 SP1 or higher of the Agilent ChemStation software Microsoft is a U S registered trademark of Microsoft Corporation Warranty The material contained in this docu ment is provided as is and is sub ject to being changed without notice in future editions Further to the max imum extent permitted by applicable law Agilent disclaims all warranties either express or implied with regard to this manual and any information contained herein including but not limited to the implied warranties of merchantability and fitness for a par ticular purpose Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing use or perfor mance of this document or of any information contained herein Should Agilent and the user have a separate
40. B Option ChemStation OpenLAB Option Concepts Guide Installation Installation Tasks on the ChemStation Computer ChemStation OpenLAB Option G2189BA is a separate installation package delivered on the ChemStation DVD It can be initially installed with the ChemStation software or added to an existing ChemStation After installation ChemStation OpenLAB Option is available for all ChemStation instances installed on the particular client PC ChemStation OpenLAB Option Concepts Guide 2 27 2 Installation Preparing the ECM Web Client Preparations You need to make sure there is an up to date version of the ECM Web Client installed on the ChemStation computer If you use Windows Vista Make sure the User Account Control feature is disabled before you connect to ECM To prepare the ECM Web Client 1 Onthe ChemStation computer Open a browser window and connect to the ECM Web Server 2 Log in to ECM All relevant hotfixes are automatically installed You may be asked to restart the ChemStation computer during the installation Installing a new ChemStation with ChemStation OpenLAB Option Before installing the software verify that all prerequisites are met see Prerequisites on page 20 The installation is divided in the following steps Installing the ECM API e Installing ChemStation Adding instruments Providing license keys e Configuring instruments To install the ECM API 1 Insert the ChemStation DVD int
41. B Option 41 username 39 user preferences 97 user 25 39 90 wW web client 11 16 web client 28 ChemStation OpenLAB Option Concepts Guide Index workflows data related 59 data related 12 methods sequence templates 14 70 OpenLAB IR 118 ChemStation OpenLAB Option Concepts Guide 161 www agilent com In This Book This guide contains installation and reference information for the ECM Interface between Agilent ChemStation and an Agilent Enterprise Content Manager ECM client server system Agilent Technologies 2008 2009 2010 Printed in Germany 04 2010 G2170 90036 EE Agilent Technologies
42. B Option Concepts Guide 35 2 Installation Uninstallation To uninstall Agilent ChemStation Windows XP 1 From the Start menu in the Task Bar select Start gt Settings gt Control Panel gt Add or Remove Programs 2 Select the Agilent ChemStation program and click Remove 3 When asked for confirmation click Yes To uninstall Agilent ChemStation Windows Vista 1 From the Start menu in the Task Bar select Start gt Control Panel gt Programs gt Programs and Features 2 Select the Agilent ChemStation program and click Uninstall 3 When asked for confirmation click Yes The program is uninstalled All files of the ChemStation folder by default C chem32 are removed Only files that have been modified by the user for example methods sequence templates or data files are not deleted To uninstall other ChemStation components During the installation of ChemStation a few additional components were installed You can remove these components using the Add or Remove Programs function with which you can also remove ChemStation The following components may have been installed together with ChemStation e PDF XChange 4 0 Microsoft NET Framework 3 5 SP1 36 ChemStation OpenLAB Option Concepts Guide 09 e ioe ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option User Permissions 38 Log In Log Out 38 ChemStation Operator and ECM User 39 Session lock
43. ChemStation computer 67 68 Working With ChemStation OpenLAB Option Data related workflows Workflow 4 Import after reprocessing Workflow 1 Workflow 2 Workflow 3 orkflow 4 Data Acquisition Data Acquisition Reprocessing Modifying Reprocessing Import R Upload z 5 Data A Data A Data A DataA 2 l Data A x Load After 2S Import after Data sing Di Reprocessing S Data A co Version 1 Version 1 Version 1 Version 2 Figure 15 Import after reprocessing The workflow Import after reprocessing see Figure 15 on page 68 illustrates how locally saved data is reprocessed and then automatically imported in ECM To save data to ECM automatically after reprocessing 1 Log in to ECM in an offline ChemStation ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB Option 4 2 From the local file system open a sequence that has never been saved to ECM before 3 In the Data Analysis view click View gt Preferences 4 On the Transfer Settings tab configure the following settings Remote Data Path Select the ECM location that you want to use for the sequence data upload Select the Import after Reprocessing check box 5 Reprocess the sequence data The data will not be uploaded if you only modify it You need to reprocess the sequence data The sequence data is uploaded as a new SC SSIZIP file version 1 to the previously defined LCDF
44. Option Concepts Guide 7 Treatment of ChemStation Legacy Data and Data Migrated from ChemStore Introduction 110 Sequence Container Migration 111 Conversion of Data Migrated from ChemStore 113 This chapter provides information on migrating legacy ChemStation sequence data to sequence container format in order to be able to upload these data sets to ECM aa Agilent Technologies 109 7 Treatment of ChemStation Legacy Data and Data Migrated from ChemStore Introduction 110 When ChemStation OpenLAB Option is installed Unique Folder Creation can not be switched off All sequence data sets that are acquired are therefore stored as sequence container Please refer to the manual Getting Started with New ChemStation Workflow for more details on working with Unique Folder Creation The sequence container format of sequences is essential for upload to ECM Therefore ChemStation legacy sequence data acquired with ChemStation prior to B 02 01 or while Unique Folder Creation was off have to be migrated to sequence container format before they can be uploaded to ECM Legacy ChemStore data that have been migrated to ECM can also be converted to be reviewed in the Navigation Table ChemStation OpenLAB Option Concepts Guide Treatment of ChemStation Legacy Data and Data Migrated from ChemStore 7 Sequence Container Migration ChemStation provides a tool to migrate non container data to sequence container format To successfully
45. Services is converted to a pdf file placed in the monitored folder and transferred by the print service to the specified location in ECM During conversion to PDF the name supplied by the system is fixed It is defined as follows e single runs datafile name pdf e sequence runs sequence name _ datafile name pdf e sequence summary reports SSR_ sequencename pdf The maximum file length for this automatically generated report name is 30 characters longer files names are truncated If due to the truncation filenames are the same the existing file is overwritten Be aware that when you specify the sequence pattern and datafile name in the sequence setup the complete pdf file name may not exceed 30 characters 142 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB Option Concepts Guide 6 eece 11 e Troubleshooting J General Problems 144 ECM Server is not Available 144 Alerts and Error Messages at ChemStation Startup 145 Error Messages in the Spooler Queue Manager 146 The chapter gives some elementary troubleshooting hints 7 Agilent Technologies 143 11 Troubleshooting General Problems ECM Server is not Available 144 If the ECM Server is not available while working with ChemStation there are two possible scenarios ECM Server is not available before during login If the ECM Server is not available while logging in to ECM from ChemStation the user cannot be authentica
46. ZIP files The ECM logbooks are available only directly in ECM Method Audit Trail Each method has a Method Audit Trail By default this Method Audit Trail contains only the comments that you must provide each time when you save a method As there is no control on the provided text there is no guarantee that the method changes are reproducible With regards to 21 CFR Part 11 ChemStation OpenLAB Option makes it possible to generate a more detailed Method Audit Trail If the function is activated the Method Audit Trail contains not only the user comments but also each individual changed parameter with its old and new value All changeable data analysis parameters are tracked This means that you can reproduce exactly which value has been changed to what when and by whom To enable the Method Audit Trail for all methods This is required if you want to comply to 21 CFR Part 11 1 Select View gt Preferences 2 In the Audit Trail Status dialog select Enable Audit Trail for this method and click OK Once enabled the Method Audit Trail cannot be disabled You can also use the ChemStation Administration Tool to enable the Method Audit Trail for all methods see ChemStation Administration Tool on page 92 ChemStation OpenLAB Option Concepts Guide Administration Regarding 21 CFR Part 11 Compliance 5 To enable the Method Audit Trail only for the currently open method You can also activate the Method Audit Trail only for one m
47. agement Settings J After Acquisition J Manage Queue on Connect J Cleanup Data on Shutdown I After Reprocessing F I After Any Data Modification Audit Trail J Import after Reprocessing I Enable Method Audit Trail for all Methods T Always Calculate Peak Performance I Enable Results Audit Trail OK Cancel Help Figure 22 ChemStation Administration Tool ChemStation OpenLAB Option Concepts Guide Administration Regarding 21 CFR Part 11 Compliance 5 Login options The following check boxes are relevant in case of an emergency that is if the ECM Server is down e Mandatory Login If you clear this check box all ChemStation instances on this client can be started without an ECM login If the ECM login used to be mandatory and the ECM Server is down clearing this check box can be used to make ChemStation accessible again Be aware that as a consequence the privileges of the ChemStation users are now unlimited The users have access to all ChemStation functions Start ChemStation when ECM is unavailable If you select this check box the ChemStation can be started when the ECM server is unavailable even if Mandatory Login is enabled The Login dialog at startup of ChemStation can be cancelled With this option selected any user can continue to work in ChemStation in case the server is down without contacting a user who has access to the Administration Tool Be aware that as a conseq
48. ail tab Several settings in the Transfer Settings tab and the Audit Trail tab may have been specified for a ChemStation instances on the computer via the ChemStation Administration Tool see ChemStation Administration Tool on page 92 In this case you cannot change the settings in the Preferences dialog On the Transfer Settings tab you must specify the following preferences in order to automatically store ChemStation data to ECM e Remote Data Path e Automatic Data Transfer Settings Transfer Management Settings Peles Paths Sequence Signal Review Options Audit Trail Transfer Settings m Remote Data Path Server Jhttp localhost Account defauld Get Server Path Location Cabinet Drawer z Folder x Select Path Automatic Data Transfer Settings Transfer Management Settings IV After Acquisition IV Manage Queue on Connect JV After Reprocessing IV Cleanup Data on Shutdown IV After Any Data Modification IV Import after Reprocessing IV Calculate Peak Performance Figure 5 Transfer Settings tab in the Preferences dialog All of these items can be specified independently for each instrument Offline and online sessions are automatically synchronized 44 ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option 3 On the Audit Trail tab you can enable the Method Audit Trail and Results Audit Trail For details on audit trails see Audit Trail
49. alid ECM user can log in This is useful for example if there is a shift change and the leaving personnel secures ChemStation until the personnel of the new shift starts work Toolbar Lock Button The toolbar lock button can be configured to lock the ChemStation session privately or non privately see Login options on page 93 Time based Depending on the ECM Account configuration ChemStation is automatically locked after a given period of time without any user interaction see Inactivity Timeout under Administration in ECM on page 89 If there is no activity in an ECM Web Client the ECM Web Client is also locked after the given period of time ChemStation and ECM Web Client are locked independently from each other The time based session lock can be configured to lock the ChemStation session either privately or non privately see Login options on page 93 40 ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option 3 OpenLAB Option User Interface in ChemStation Overview of new interface elements With the installation of ChemStation OpenLAB Option the following new menus menu items and interface elements are available Menu New elements Description Method Sequence gt Sequence Parameters Sequence Parameters tab Sequence gt Sequence Parameters Sequence Output tab Report View gt Preferences ECM Toolbar depending on the current vie
50. ate with the Windows users Each user can be member of a specific group The available groups depend on the ECM configuration You must assign a specific ECM role to each group You can also assign roles to single users however for the sake of clarity it is strongly recommended to assign roles only on the group level The roles are equipped with numerous specific privileges which define what the users are allowed to view or do in ECM and in ChemStation Once you created a new ECM user group or role you can not delete it again You can only deactivate the unused item Default roles and privileges There are a number of default roles and privileges in ECM that are created during the installation of ECM and ChemStation OpenLAB Option The following tables show an overview of these roles and privileges Name Description Starting with S Default ChemStation role Can be restored by the Reset Roles function Starting with Default ECM role Can be restored by the Reset Roles function ChemStation OpenLAB Option Concepts Guide 25 2 26 Installation Name Description Starting with CS Privilege related to ChemStation For details on the ChemStation privileges see Appendix on page 149 Starting with Content Privilege related to ECM Starting with System Privilege related to ECM In addition you can create your own roles in ECM or grant further privileges to the default
51. be created You may select an existing folder or create a new one When all fields are filled in the migration can be started The following steps will be performed The sequence container directory will be created The sequence template will be copied to the container It will also be converted to a state where it is able to reprocess data files in Data Analysis view The methods referenced in the sequence table are copied from the specified method path to the container folder e The data files the sequence logbook and the batch file are copied from the data source directory to the destination directory e According to the information in the sequence table a copy of the corresponding method is copied to each data file as DA M When the container migration is completed a success message is displayed in the Messages and Warnings field Otherwise a warning message indicates any problem during migration Details about the warning can be obtained by double clicking the warning message 112 ChemStation OpenLAB Option Concepts Guide Treatment of ChemStation Legacy Data and Data Migrated from ChemStore 7 Conversion of Data Migrated from ChemStore When ChemStore sequence data have been migrated to ECM they are already available in the form of sc ssizip files and thus ready to be downloaded into ChemStation Data Analysis view However such sequence containers have to be converted to be ready for review in the Navigation Tab
52. ccording to the password policy 21 CFR Part 11 requires that company the laboratory has a password policy 1 In ECM select the Administration page 2 In the navigation pane select the Account Administration node 3 Double click the Users Groups Roles item ChemStation OpenLAB Option Concepts Guide Preparations Administration Regarding 21 CFR Part 11 Compliance 5 The Account Administration dialog opens 21 CFR Part 11 does not define any specific rules for the password settings However your company must have defined a password policy You may consider the following settings e User cannot change password e User must change password after next login Note that the minimum password length is defined in the ECM Account configuration see Account configuration on page 89 Roles and folders ECM allows you to assign specific roles to users or user groups This can be done at the global level for the entire ECM Account or individually for specific folders For example a specific user group may have the Contributor role for folder A but at the same time have only the Reader role for folder B If you want to assign roles at the folder level you must first enable this feature in ECM The setting is valid for the complete ECM Account To enable roles for folders 1 In ECM select the Administration page 2 In the navigation pane select the Account Administration node 3 Double click the Users Groups Roles item Th
53. cted compounds These fields are sufficient for many standard analysis tasks However for some specific tasks you may need to save additional information on the samples or compounds In this case you can define the so called custom fields Custom fields are available for sample information and for compound information The custom fields definition is saved as part of the method definition When you define custom fields you can define a suitable field name and data type for the additional information according to your needs After you have defined the custom fields you can enter the actual values in the sequence table of the current sequence These values will be shown on ChemStation reports and are available also for OpenLAB Intelligence reports In OpenLAB Intelligence reports the values can even be used for calculations or statistical evaluations In addition you can use custom fields to flag all samples related to a specific project or study This flag is then used by OpenLAB Intelligence Reporter to find all results related to this specific project or study ChemStation OpenLAB Option Concepts Guide Custom Fields 6 Setting Up Custom Fields The custom fields definition is part of the method You can define up to ten custom fields related to the samples and up to ten custom fields related to the compounds Also you can import the custom fields definitions from another existing method To define new custom fields 1 Select t
54. d might be interrupted In this case the remaining data is written to an internal queue If you select the check box Manage Queue on Connect ChemStation tries to upload the remaining data to ECM each time a connection to ECM is established that is each time a user logs on to ECM from ChemStation Alternatively you can open the Spooler Queue Manager dialog see Spooler Queue Manager on page 50 at any time with the ECM gt Manage Queue command in the Data Analysis view Cleanup Data on Shutdown If you select this check box ChemStation checks the local file system at each shutdown It deletes all local data and sequence files that are known to be stored in ECM as well Methods and sequence templates remain on the local file system If you select the Cleanup Data on Shutdown check box you should also select the Automatic Data Transfer Settings After Acquisition After Reprocessing and After Any Data Modification Otherwise if the users forget to upload the data to ECM before closing ChemStation data might be lost Consider selecting the Cleanup Data on Shutdown check box when the system shall be compliant to 21 CFR Part 11 Using this function prevents unauthorized access to the local data files Alternatively you can open the Data Cleanup dialog at any time with the ECM gt Cleanup Data command in the Data Analysis view This dialog box lists all data sets related to ECM apart from the currently loaded data The follow
55. d Down buttons To import custom fields from an existing method 1 Make sure the method with the custom fields is available in your local file system 2 Load the target method the one to which you want to import the custom fields definition 3 Select Method gt Custom Fields Setup 4 Click Import A dialog opens where you can select the source method from the local file system 5 Click OK ChemStation OpenLAB Option Concepts Guide Custom Fields 6 Specifying Custom Fields Values The specific values of the predefined custom fields depend on the actual sequence Therefore the values are specified in the sequence table To provide sample custom fields values 1 In the Method and Run Control view load the required sequence 2 Select Sequence gt Sequence Table to open the sequence table 3 Click Custom Fields The Set up Custom Fields values dialog opens The Sample Custom Fields tab is active Each predefined custom field is shown in a separate column Mandatory custom fields are marked with in front of the field name The lines correspond to the lines in the sequence table HE Set up Custom Fields values ioj xj Sample Custom Fields Compound Custom Fields Weight Figure 24 Set up Custom Fields values Sample Custom Fields Sample name 2 Vial 2 4 Enter the required values for each sample and custom field You can only start a sequence after the mandatory fields have been co
56. d policy realized in ECM including E mail Notification See To configure the password settings for an ECM Account according to the password policy on page 90 E Signatures prepared messages and privileges See Using electronic signatures on page 96 ChemStation with ChemStation OpenLAB Option and mandatory ECM login See Installing a new ChemStation with ChemStation OpenLAB Option on page 28 Automatic Data Transfer Settings and Transfer Management Settings activated See ECM Preferences on page 44 Audit trail active for methods and results See Method Audit Trail on page 84 and Results Audit Trail on page 85 Emergency Plan available based on options of the Administration Tool See ChemStation Administration Tool on page 92 ChemStation OpenLAB Option Concepts Guide 83 5 Administration Regarding 21 CFR Part 11 Compliance Audit Trails and Logbooks 84 In order to comply to 21 CRF Part 11 ChemStation OpenLAB Option offers various audit trails and logbooks to document all activities associated with methods results reports or with ECM files generally These audit trails and logbooks track all changes that are made to any file including data acquisition re analysis and long term archiving The audit trails are stored in separate files which are stored together with the sample or method data The audit trail files are archived together with the other data in the according SSI
57. d sequence template ECM Version Version number of the file in ECM 3 You can now manually select the methods that are to be updated Alternatively you can via the drop down list deselect all methods select all methods select to those methods with a higher version number in ECM or select all methods that have been modified locally After pressing OK the selected local methods sequence templates are updated with the version in ECM ChemStation OpenLAB Option Concepts Guide 77 4 Working With ChemStation OpenLAB Option Workflows for Methods and Sequence Templates 78 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB Option Concepts Guide 5 Administration Regarding 21 CFR Part 11 Compliance Introduction to 21 CFR Part 11 80 21 CFR Part 11 Requirements 81 General Aspects of Data Security in Computerized Networks Open Versus Closed Systems 81 Overview of Configuration Steps Required for Part11 83 Audit Trails and Logbooks 84 Method Audit Trail 84 Results Audit Trail 85 Report History 86 ECM Audit Trail 86 ECM System Log 88 Administration in ECM 89 Account configuration 89 Users Groups Roles 90 Administration of ChemStation Settings 92 ChemStation Administration Tool 92 Electronic Signature 95 Preparation 95 Using electronic signatures 96 This chapter explains the purpose of 21 CFR Part 11 and its implementation in ChemStation with ChemStation OpenLAB Option te Agilent Technologies 79 5 Ad
58. d the data analysis parameters for a sample The data is uploaded even if you do not reprocess the sequence For more information please refer to Workflow 2 Offline review during acquisition on page 62 After Reprocessing If you select this check box the sequence data container is automatically uploaded to ECM each time after you reprocessed the sequence For more information please refer to Workflow 3 Reprocessing data and automatic upload on page 64 Import after Reprocessing If you select this check box a sequence that is only stored locally is automatically uploaded to ECM after reprocessing For more information please refer to Workflow 4 Import after reprocessing on page 68 Calculate Peak Performance This option influences the amount of transferred data If you select this option extended performance values such as noise or system suitability are always calculated saved to ECM and can be used in OpenLAB Intelligence Reporter If the check box is cleared the extended performance values are only available if you choose the ChemStation report styles Performance or Extended Performance For more information please refer to Calculation of performance values on page 126 ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option 3 Transfer Management Settings Manage Queue on Connect If the connection to ECM breaks down for any reason a running data uploa
59. der to modify those items in ChemStation you should check them out from ECM manually Otherwise there is no guarantee that you are working on the latest version If the file already exists on the ChemStation computer in the specified location you must choose a different download location The LCDF path of the loaded method sequence template is shown in the ChemStation toolbar in ChemStation 4 Make some changes to the method sequence template The modified method is indicated by Qs a modified sequence templates by in the Navigation Pane 5 Select ECM gt Save Method or ECM gt Save Sequence Template respectively to save the changed method sequence template If you have not checked out the item before loading it from ECM and another ECM user has checked out the item in the meantime you cannot proceed with the upload back to ECM A warning message is displayed and it is not possible to save the item back to ECM until the other user has released the checked out item ChemStation OpenLAB Option Concepts Guide 75 4 Working With ChemStation OpenLAB Option Workflows for Methods and Sequence Templates 6 When the Add File dialog opens enter a reason for the upload and click OK The reason is then shown in the ECM Audit Trail see ECM Audit Trail on page 86 The progress of the upload is displayed in a window until the item is uploaded to ECM The M SSIZIP S file is uploaded with its original name to its original LCDF pa
60. e 73 marker 2 With these icons you can only check out the latest version of an item In order to see more details regarding the type and version of the available items select the Detail view see Figure 18 on page 73 marker 3 To open an older version of an item select the Open Revisions command from the Open menu see Figure 19 on page 74 marker 1 This opens the File Versions dialog where all available versions of the item are listed see Figure 20 on page 75 ECM Desktop Open Look in methoden ore oaen teas gt ACH1 M SSlzip E ACH1 b M SSizip E ACH1 c M SSlzip Filename MEENE aE Open Open Revisions en a Open As Checked Out Open With Original Program Files of type M SSlzip Figure 19 Open Revisions command ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB Option 4 File Versions Filename ACH1 M SSIzip Version Last Modified Date 6 9 2008 4 07 14 PM GMT 02 00 TEUBNER ACHIM A Net 6 9 2008 4 04 29 PM GMT 02 00 TEUBNERLACHIM A Net Figure 20 File versions dialog 3 Select Open in either dialog to download the item to ChemStation In order to prevent other users from modifying the item it is possible to select the Open As Checked Out command to mark the item as checked out from ECM see Figure 19 on page 74 marker 2 Unlike the data files the methods and sequence templates are not automatically checked out of ECM In or
61. e Account Administration dialog opens 4 On the Roles tab select the required role and click Edit 5 Select the Available in folder access tab check box ChemStation OpenLAB Option Concepts Guide 91 5 Administration Regarding 21 CFR Part 11 Compliance Administration of ChemStation Settings 92 ChemStation Administration Tool The ChemStation Administration Tool offers a number of functions which are helpful if the ECM Server is down and the connection from the ChemStation client to the ECM Server is lost As one of these functions is to switch off the mandatory ECM login the access to the ChemStation Administration Tool is strictly limited The ChemStation Administration Tool can only be started by users who are a member of the local user group CSAdministrators see Enabling users to start the ChemStation Administration Tool on page 33 To start the ChemStation Administration Tool 1 From the Start menu in the Task Bar select Start gt All Programs gt Agilent ChemStation gt ChemStation Administration Tool ChemStation Administration Tool Login Vv Mandatory Login I Timebased session lock locks private I Start ChemStation when ECM is unavailable gl Toolbar Lock Button locks private I Break Session Lock M Data Handling and Audit Trail Configuration C Use Settings from Preferences Use these Settings for all Instances on this Computer Automatic Data Transfer Settings _ Transfer Man
62. e Checklist and Method Information Run Print preview a report Run Perform interactive recalibration Edit Modify report calculation print style edit Instrument Curves dialog View Access to Report Layout view Edit Save a report template Run Reprocess a sequence Edit Access to the Retention Time Lock menu GC only Edit Access to Retention Time Search menu GC only Run Start acquisition single sample or sequence Edit Save sequences Delete Delete sequences in ChemStation Explorer Edit Modify sequence summary report and extended statistics settings Edit Edit noise ranges and performance limits ChemStation OpenLAB Option Concepts Guide 151 12 Appendix Privilege Description CS Transfer Preference Edit Edit the Transfer Settings in the Preferences CS Tune View Access to Tune view LC MSD ChemStation only CS Verification View Access to Verification O0 PV view 152 ChemStation OpenLAB Option Concepts Guide Appendix 12 ChemStation Roles in ECM Please note the default ChemStation roles do not contain any ECM privileges Table 3 Default CS Administrator privileges Privilege View Edit Delete Add Run CS Audit Trail X CS Break Session Lock X CS Command Line X CS Control X CS Data X X CS Data Analysis X CS Diagnostic X CS Full Menu X CS Instrument Setup X CS Logbook X X CS Manage Transfer Queue X CS Manual Integration X CS Method X X CS Me
63. enLAB Summary Report on page 123 A single sequence is acquired in ChemStation and the data is reviewed in ChemStation first The OpenLAB summary report is created for this single sequence only Multiple Sequence Summary Report Multiple sequences are acquired over time days to weeks A user subsequently searches for these sequences and creates a summary report for the selected sequences Study Project Summary Report A large number of sequences 10 s to 100 s are acquired over time weeks to months A user searches for all data for these sequences and creates a complex study summary report based on these data ChemStation OpenLAB Option Concepts Guide Interface to OpenLab Intelligence Reporter 8 Only the Single Sequence Summary Report can be directly generated from ChemStation For the other two reporting workflows you need to perform all tasks in OpenLAB Intelligence Reporter See the OpenLAB Intelligence Reporter documentation for more details When printing an Intelligence Report directly in the ChemStation only a report based on the latest version of the data can be created For reports based on earlier versions the report template has to be modified or the report has to be created in the OpenLAB Intelligence Reporter software Example reports The reports generated by OpenLAB Intelligence Reporter can include a wide variety of information such as e Custom calculations e g summary calculations statistics and
64. entries related to specific categories Files Folders System Scheduler or Instrument Also you can print the entries or export them to a file 88 ChemStation OpenLAB Option Concepts Guide Administration in ECM Administration Regarding 21 CFR Part 11 Compliance 5 min When you install ChemStation OpenLAB Option you need to carry out certain basic configuration tasks in ECM see Installation and Configuration Tasks on ECM Server on page 22 In addition there are several other settings in ECM that are relevant with regard to 21 CFR Part 11 These settings are described in the following section Account configuration To configure the ECM Account 1 In ECM select the Administration page 2 In the Navigation Pane select the Account Administration node 3 Double click the Configuration item The Account Administration dialog opens Account Administration Configuration Security J Lockout users after unsuccessful login attempts Inactivity timeout minutes Minimum password length 6 System email addresses System administrator email I Archive administrator email File upload options V Require entry in Reason fields ChemStation OpenLAB Option Concepts Guide Network logon This user is responsible for obtaining the User and Group Lists from the domains Username companyuser Example domain username Cluster configuration Application Service File Transfer Serve
65. eporter Introduction 116 Prerequisites 118 Typical reporting workflows 118 To create a Single Sequence OpenLAB Summary Report 123 Interface Components Concerning OpenLAB IR 124 Template selection in Sequence Output 124 Automatic Creation of OpenLAB Intelligence Report at the End of the Sequence 125 OpenLAB IR commands inthe ECM menu 125 Calculation of performance values 126 This chapter provides information on the integration of OpenLAB Intelligence Reporter in Agilent ChemStation ait Agilent Technologies 115 8 Interface to OpenLab Intelligence Reporter Introduction 116 Agilent OpenLAB Intelligence Reporter provides advanced reporting functions for any chromatographic data generated by Agilent ChemStation or Agilent OpenLAB ICM The reports are based on the standardized ACAML 1 1 or 1 2 data which is automatically generated by ChemStation B 02 01 SR1 or higher with ChemStation OpenLAB Option OpenLAB Intelligence Reporter enables you to generate knowledge by creating various types of intelligent reports e Sequence reports with summary calculations and statistics e Reports of complex tests with condensed information for example by visualizing key results or by presenting trend charts e Reports presenting decision based results for example with flagged outliers or with results automatically sorted by pass fail criteria You can either use OpenLAB Intelligence Reporter to report the results currently shown
66. er 138 To set the printer to unattended mode 139 Configuring ECM Print Services Adobe Distiller 140 To set the printer to unattended mode 141 Working with ECM Print Services in ChemStation 142 This chapter gives a brief overview of how to install and configure the Print Services This enables you to automatically upload ChemStation reports to ECM in a PDF format ot Agilent Technologies 135 10 Using Print Services in ChemStation ECM Print Services 136 ECM Print Services are print management systems that transfer human readable electronic documents to ECM They can be used to print ChemStation reports to ECM in PDF format When you add and configure a print service it appears as an available printer on your computer When you print with ECM Print Services a PDF file is created and automatically uploaded to the ECM system In addition you can also set up the system to print additional hard copies to a conventional printer ECM Print Services can be installed for ECM Server revision 3 3 1 or later The ECM Print Service consists of two components The ECM Print Service Manager where you add and manage printers for the ECM Print Service The ECM Print Service which monitors a folder on your local disk drive When a print service receives a print job the print driver prints to a file in the monitor folder Then the ECM Print Service intercepts the file and uploads it to ECM In order for a file to be u
67. ethod This might be useful for example when you finished the development of new method and want to track all further changes 1 Select Method gt Enable Audit Trail 2 On the Audit Trail tab select Enable Method Audit Trail for all methods To view the Method Audit Trail for the currently open method in ChemStation 1 Select Method gt Method Audit Trail To remove the detailed Method Audit Trail Once a method is enabled for the detailed audit trail you cannot disable it again The only way to get rid of an existing Method Audit Trail is to save the method under a different method name In this case the only hint in the new method s audit trail is a comment about the method being based on another method Results Audit Trail Manual integration events are not saved in the method Therefore the Method Audit Trail contains no information on manual integration events These events are only saved in the data file Nevertheless they have an influence on the results Manual integration events are therefore saved as part of the Results Audit Trail If activated this Results Audit Trail is added to the existing Data File Logbook file name RUN LOG By default the Data File Logbook only contains the acquisition parameters and reprocessing information for each sample The Results Audit Trail additionally tracks the changes of all data analysis parameters for a sample ChemStation OpenLAB Option Concepts Guide 85 5 86 Admini
68. folder is C Chem32 Click Next 8 Click Install ChemStation is now being installed This can take several minutes 9 Click Finish The Setup Wizard Instruments dialog opens Proceed now with adding the instruments ChemStation OpenLAB Option Concepts Guide 29 2 30 To add instruments 1 In the Setup Wizard Instruments dialog click the Add buttons to add the required instruments l Setup Wizard Instruments 0 x Selected instruments for ChemStation Add LC EHC ChemStation Instrument 1 GC ChemStation Instrument 2 Add GC i General Addon products Add CE Add LC MS Data Analysis Only LC MS Data Analysis Figure 2 Setup Wizard Instruments 2 Under General Addon products select the ChemStation OpenLAB Option check box 3 Click Next The Setup Wizard Licenses dialog opens 4 Proceed now with providing the license keys To provide license keys 1 In the Setup Wizard Licenses dialog enter a valid license key for ChemStation OpenLAB Option in the input field at the bottom The applicable license product and license numbers are printed on your Software Certificate and Registration Packet ChemStation OpenLAB Option Concepts Guide Installation 2 Installation Tasks on the ChemStation Computer NOTE Note that any Windows user with administrative privileges can remove the G2189BA OpenLAB Option license and thus disable OpenLAB Option functionality from the ChemStation I
69. he Method and Run Control view Load the required method Select Method gt Custom Fields Setup The Set up Custom Fields definitions dialog opens It contains two sections one for sample custom fields and one for compound custom fields GE Set up Custom Fields definitions TEST M Sample Custom Fields Name Type Default value Mandatory Compound Custom Fields Name Type Default value Mandatory oK Cancel jal Help Figure 23 Set up Custom Fields definitions dialog ChemStation OpenLAB Option Concepts Guide 101 102 Custom Fields 4 Click to add a new custom field in the according section 5 Enter a suitable name for the new custom field for example Color If you create sample custom fields named Project or Study these custom fields will be reported twice in the acaml file in the regular custom fields section and also in the projects study mapping This enables OpenLAB Intelligence Reporter to find all results related to a specific project or study 6 Select a suitable data type for example TEXT 7 If appropriate enter a default value for example Blue 8 If appropriate select the Mandatory check box to ensure that the custom field is always filled If you make a custom field mandatory you should also provide a default value 9 If required click to delete a selected custom field 10 If required adjust the order of the custom fields with the Up an
70. he end of the sequence you select Preview at end of sequence in the Sequence Output You select the Automatic Data Transfer Setting After Acquisition You start the sequence 2 After the acquisition all data is automatically transferred to ECM The result data and metadata is automatically extracted from the acaml files into the Reporting Database 4 In ChemStation You trigger the creation of the report by clicking Create OpenLAB Intelligence Report If Preview at end of sequence was selected in the Sequence Output the report is created automatically without additional user interaction ChemStation OpenLAB Option Concepts Guide 117 118 Interface to OpenLab Intelligence Reporter The previously selected report template is automatically applied to the new sequence data The resulting report is transferred to the ChemStation client computer The resulting OpenLAB IR report is shown in ChemStation Prerequisites If you want to use OpenLAB Intelligence Reporter the following prerequisites must be met OpenLAB ECM is installed OpenLAB Intelligence Reporter is installed ChemStation OpenLAB Option is installed The chromatographic data has been uploaded to ECM Typical reporting workflows Depending on the scenario there are different workflows when working with OpenLAB Intelligence Reporter Typically one of the following workflows applies Single Sequence OpenLAB Summary Report see To create a Single Sequence Op
71. he report template will be automatically applied ChemStation OpenLAB Option Concepts Guide Interface to OpenLab Intelligence Reporter 8 You can select a different report template in OpenLAB Intelligence Reporter at any time The setting in the Sequence Output in ChemStation is only used as a default setting Automatic Creation of OpenLAB Intelligence Report at the End of the Sequence Under Sequence gt Sequence Output you can select Preview at end of sequence for the currently loaded sequence template This setting is optional It requires that an OpenLAB Intelligence Report Template is also selected With this setting enabled the OpenLAB Intelligence Report will be created automatically at the end of sequence acquisition or sequence reprocessing based on the selected template OpenLAB IR commands in the ECM menu In the ECM menu there are two commands related to OpenLAB Intelligence Reporter Start OpenLAB IR This command opens OpenLAB Intelligence Reporter No data is passed from ChemStation to the Reporter Client You can select the required data directly in the Reporter Client Create OpenLAB IR Report T After acquiring or reprocessing sequence data you can create a report in OpenLAB Intelligence Reporter as soon as the data has been uploaded to ECM The report is based specifically on the current sequence that is the sequence that is currently loaded in the Data Analysis view in ChemStation You must first u
72. hen opening a file from ECM the ECM Open dialog allows you to search for files of interest using the magnifying glass icon see Figure 33 on page 129 Using the Quick Search you can search through various alphanumeric fields by entering a search key such as an operator name On the upcoming search page you select the Advanced tab where depending on the enabled filter packages various keys are enabled see Figure 34 on page 129 128 ChemStation OpenLAB Option Concepts Guide Attribute Extraction Services for ChemStation Data 9 Attribute Extraction Services for ChemStation Data ECM Desktop Open x Look in GD Test Data a 1to3of3 4 gt LIR 2007 1 2007 02 27_13 43 i LIR 2007 2 2007 02 28_09 54 30 sc ssizip LIR 2008 1 2007 02 28_14 25 40 sc ssizip File name LIR 2007 1 2007 02 27_13 43 28 sc ssizip os Open Files of type SC SSlzip Figure 33 Search options Search Quick Smart Advanced Options Advanced Search Query Available keys Search Expression Adobe PDF ChemStation Chemstation GEMS ChemStation GCMS DrugQuant Chemstation LCMSD ChemStation XML Empower TNF gt EMX Templates File Information General Microsoft Office PDF Templates Text Open Save Cancel Advanced Search Search in WAD_Support Lab A LC Test Data Figure 34 Filters available in search options In the Search dialog you can specify the available keys and
73. ill be automatically connected to ECM with the same login information silent login If you are not connected to ECM all of the ECM functions are grayed out You can log in to ECM from the following ChemStation views e Method and Run Control e Data Analysis Once you have logged in to ECM it is possible to upload data to ECM and simultaneously work on the local ChemStation file system The login is dependent on the instrument session only one user can be logged in to ECM at any one time If another user wants to log in you must first log out ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option 3 User credentials The Login dialog requires you to enter a set of valid authorization details in order to log in to ECM The login information is ECM Server specific and will be provided by the ECM administrator You need to enter the following login details Server URL the URL of the ECM Server e Account you can store content to the locations assigned in the specific account one ECM Server may have several accounts e Username the user name defined in the ECM Account or your NT domain user name depending on the user configuration in ECM e Password the password provided by your administrator which can be changed on request for ECM built in users or the password of your NT domain account if you are logging in using your NT domain user name e Log onto the domain administrati
74. in ChemStation or you can define the required data in the Reporter Client For more detailed information on OpenLAB Intelligence Reporter please see the OpenLAB Intelligence Reporter documentation ACAML version ChemStation stores all data in the ACAML format ACAML Agilent Common Analytical Markup Language which results in acaml files There is one acaml file for each sequence or single run When the data is uploaded to ECM the acaml file is part of the SSIZIP sequence container OpenLAB Intelligence Reporter uses the data provided in these acaml files In ChemStation B 04 02 the ACAML schema is updated from version 1 1 to 1 2 This version 1 2 of the ACAML schema is only supported by OpenLAB Intelligence Reporter revision A 02 01 ChemStation OpenLAB Option Concepts Guide Interface to OpenLab Intelligence Reporter 8 Data flow example When using ChemStation together with ECM and OpenLAB Intelligence Reporter data is transferred at different times from the ChemStation client to the ECM Server and back There are several possible scenarios for the data flow depending on the workflow you follow As an example the following figure shows the data flow for creating a single sequence report Figure 29 Example Data flow for creating a single sequence report 1 In ChemStation You select a report template for the OpenLab Intelligence Reporter in the Sequence Output If the report is to created automatically at t
75. ing columns are available Directory Location of the local file ECM Information ECM server account information and LCDF path of the file in ECM Last Modified Date Time when the copy in ECM was last changed ChemStation OpenLAB Option Concepts Guide 49 3 50 Basic Concepts of ChemStation OpenLAB Option Locally Modified Information whether the local copy has been modified e Local Version Version that was downloaded to the local directory You can now manually select the data sets to be deleted from the local disk Alternatively via a drop down list deselect all data sets select all select only single runs select only sequence containers select items older than today or items older than a week After pressing OK the local copies of the selected data sets are deleted Both automatic cleanup on shutdown and manual cleanup are only possible if the following conditions are fulfilled e the ChemStation user is logged on to ECM no other instance of the ChemStation instrument is open the spooler queue is empty If one of these conditions is not fulfilled automatic cleanup will not be performed and it is not possible to open the Data Cleanup dialog Spooler Queue Manager The Spooler Queue Manager dialog is opened via ECM gt Manage Queue If you selected the check box Manage Queue on Connect and there are interrupted transfers the dialog is also opened when you start ChemStation With this dialog y
76. inistration Tool The ChemStation Administration Tool is automatically installed as a part of ChemStation OpenLAB Option during the procedure described above The ChemStation Administration Tool offers you to change the transfer settings see Automatic Data Transfer Settings on page 47 for all ChemStation instances on a computer in a single step In addition there are a number of functions which are helpful if the connection from the ChemStation client to the ECM Server is lost As one of these functions is to switch off the mandatory ECM login access to the ChemStation Administration Tool must be strictly limited During the Installation of ChemStation OpenLAB Option the local user group CSAdministrators is automatically created Only members of this group are allowed to run the ChemStation Administration Tool The user who installs ChemStation is automatically added to the CSAdministrators group Additionally the Windows group Administrators and the user who installs ChemStation are granted Full Control privileges on the Administration Tool program executable Agilent ChemStation KCM ECMAdmin exe itself thus they are able to run the tool ChemStation OpenLAB Option Concepts Guide 33 2 Installation Installation Tasks on the ChemStation Computer NOTE See Administration of ChemStation Settings on page 92 for more details on the ChemStation Administration Tool To add a Windows user to the CSAdministrators group 1 Fr
77. ion 2 Load a sequence template Your ECM user name is automatically inserted as operator name into the sequence template 3 In the Data Analysis view click View gt Preferences 4 On the Transfer Settings tab configure the following settings Remote Data Path Select the ECM location that you want to use for the sequence data upload Select the After Acquisition check box Select the After Any Data Modification check box 5 Start the acquisition While the acquisition is running the raw data method definition and a copy of the sequence template are stored locally on the ChemStation computer 6 Open an offline ChemStation and change some data analysis parameters for one of the already finished samples Save your changes locally 7 After the acquisition has been finished two things will happen The original raw data is automatically uploaded as an SC SSIZIP file Version 1 to ECM to the previously defined LCDF location The LCDF of the new sequence is shown in the toolbar in the online ChemStation The file name of the sequence container is determined by the settings in the sequence template for more details on the sequence template settings refer to the manual Understanding Your ChemStation The sequence icon in the ChemStation Navigation Pane changes from to 9 The ECM forced upload dialog opens in the online ChemStation Click OK to confirm that you finished all work in the offline instance As soon as yo
78. is uploaded to ECM local copies of the files still remain in the ChemStation file system If an item is loaded from ECM back into ChemStation it is automatically loaded into its original location Different options are available regarding the automatic upload of single run sequence data to ECM Loading back stored data from ECM to ChemStation however always requires a manual load action Methods and sequence templates require always a manual upload to ECM as well as a manual load or update into ChemStation For downloading data from ECM several load commands are available in the ECM menu Depending on the current view you can load different files from ECM In the Data Analysis view you can load single run data or sequence data These data are automatically set to the status checked out in ECM In the Method and Run Control view you can load methods and sequence templates These items are only retrieved and not checked out The following workflows are examples that represent typical tasks done with ChemStation OpenLAB Option ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB Option 4 Data related workflows Workflow 1 Acquisition and automatic upload Workflow Data Acq iB uisition Figure 9 Acquisition and automatic upload ChemStation OpenLAB Option Concepts Guide 59 4 Working With ChemStation OpenLAB Option The workflow Acquisition and automatic upload see Figure 9 on page 59 illustrates
79. le The conversion process is started automatically after downloading the data from ECM 1 Select ECM gt Load Data and select the data set you want to view in ChemStation A message is displayed that the sequence data will be reprocessed Press Yes to continue Data Migration xi 2 jJ This Data Container will now be reprocessed To fully migrate the data this is required only once Do you want to continue If you press No the local copy of the data set will be deleted immediately 2 When asked to save the sequence file press Yes In order to prevent printing reports for the reprocessing step for conversion the Sequence Output settings of the sequence are changed in the following way e Print sequence summary report on Report to printer off Report to file off Report to PDF off Report to HTM off e Print individual report for each run as well off 3 Now you can review or reprocess the sequence data If the sequence container is uploaded to ECM after conversion either automatically after reprocessing or manually the new versions of the sequence can be loaded into ChemStation without further conversion steps later on ChemStation OpenLAB Option Concepts Guide 113 7 Treatment of ChemStation Legacy Data and Data Migrated from ChemStore Conversion of Data Migrated from ChemStore 114 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB Option Concepts Guide 8 Interface to OpenLab Intelligence R
80. le dialog 21 98 Contributor role 26 electronic signature 17 80 95 Add Folder privilege 26 ane Create OpenLAB Intelligence Report 117 error messages 145 administration tool 31 Create OpenLAB IR Report 125 administration tool 33 92 a CSAdministrators 34 F AES 127 128 i a custom fields reporting 105 file format 56 after acquisition 60 63 aie custom fields values 103 filter keys 128 after any data modification 63 67 custom fields 100 filter after any data modification 48 after reprocessing 67 D after acquisition 47 ACAML 131 folder 16 47 91 data file logbook 85 after reprocessing 48 j G attribute extraction service 127 128 default printer 141 judittraii 17 84 diagnosis view 42 group 34 90 authentication 38 domain 39 l available in folder access tab 91 drawer 16 47 import after reprocessing 48 68 B E inactivity timeout 90 breaks ssioniocdk 35 Easy Access 21 installation ECM Desktop Open dialog 65 73 on ChemStation computer 27 c ECM forced upload 63 on ECM server 22 binet 16 47 ECM print services 136 fe i i ECM system log 88 K calculate peak performance ECM user 39 keys 128 checked out 65 73 75 ChemStation OpenLAB Option Concepts Guide 159 Index L LCDF 16 26 45 license key 30 loaddata 64 load method 73 location 16 47 lockout 40 90 logbook 84 login 32 38 93 M manage queue 43 49 mandatory login 32 93 menu items grayed out 144 metadata 127 method audit trail 84
81. ls Type Adobe Distiller Name Specify a unique name e g Chem1 Print Define the printer security options in accordance with your organization s security policies In the upcoming Add Port dialog choose Add Port and select the specified monitor folder on the ChemStation computer Click Add to continue and browse for the monitor folder for the ECM print service Open the printer configuration by marking your specific printer and select the Configuration tab ECM you need to specify the ECM data path where the uploaded files will be stored after transfer Settings Transfer specific settings Hardcopy Printers It is also possible to get a hardcopy printout Email It is possible to enable e mail notification r details refer to the ECM Print Services online help Click Apply to apply the configuration to the Print Service and leave the dialog box with OK Depending on the Acrobat Distiller version in use additional configuration settings are necessary A message requests you to perform certain tasks Example for Adobe Distiller Rev 6 00 In Start gt Settings gt Printers open the properties of the newly added printer Select Print Preferences In the Adobe PDF Conversion Settings deselect View Adobe PDF results ChemStation OpenLAB Option Concepts Guide Using Print Services in ChemStation 10 e In the Adobe PDF Output Format select the monitored path of the ChemStation computer Select Edit for the
82. ministration Regarding 21 CFR Part 11 Compliance Introduction to 21 CFR Part 11 80 Effective August 20 1997 the U S Food and Drug Administration FDA released and published a new rule to enable pharmaceutical companies to approve their results with electronic signatures and to transfer paper trail documentation into electronic records This rule is known as 21 Code of Federal Regulations Part 11 referred to as 21 CFR Part 11 and applies to all industry segments regulated by the FDA The impact of this rule on current work practices and data handling in the pharmaceutical industry has been much higher than expected The industry wanted to have a rule on electronic signatures but what they got was a rule on electronic records Martin Browning former FDA inspector during a validation seminar in Washington D C 21 CFR Part 11 places high emphasis on the implementation of all measures to protect and secure electronic records Notwithstanding the uncertainties and the changes that 21 CFR Part 11 requires in the behavior of both the pharmaceutical industry and the vendors of chemical analysis equipment it is well worth implementing in today s laboratories because it can help the industry with one of the most important issues in pharmaceutical research bringing new drugs on the market faster The major benefits of this shift towards electronic data management are in the potential productivity increase for the industry The industr
83. mpleted ChemStation OpenLAB Option Concepts Guide 103 6 Custom Fields Specifying Custom Fields Values To provide compound custom fields values 1 Select the Compound Custom Fields tab HE Set up Custom Fields values Sample Custom Fields Compound Custom Fields e pmetnycnthacte I L gt J gt Line Vial Sample name Method Weight gt 2 Vial 2 BATCH 3 Figure 25 Set up Custom Fields values Compound Custom Fields NOTE This tab is only available if compounds have been set up in the method s calibration table 2 Select the required compound from the drop down list at the top or click Ea Ea Ea or Bal to navigate to the required compound 3 Enter the required values for each sample and custom field 4 Select the other compounds and provide the values accordingly 5 Click OK 104 ChemStation OpenLAB Option Concepts Guide Custom Fields 6 Reporting of Custom Fields Custom fields values are always saved to ECM and are therefore always available in OpenLAB Intelligence Reporter However they are not automatically shown in ChemStation reports If you want to display the custom fields in your ChemStation reports you must first adjust the report options To display custom fields in ChemStation reports 1 Select the Data Analysis view 2 Select Report gt Specify Report 3 Select the check boxes Add Sample Custom fields to Sample info and Add Compound Custom fields 4 Click OK The cu
84. mponents Concerning OpenLABIR 124 9 Attribute Extraction Services for ChemStation Data 127 Attribute Extraction Services for ChemStation Data 128 ACAML Filter 131 ChemStation XML Attribute Extraction Service 132 ChemStation Filter 133 10 Using Print Services in ChemStation 135 ECM Print Services 136 Setting Up ECM Print Services 137 Configuring ECM Print Services for use with Amyuni PDF Converter 138 Configuring ECM Print Services Adobe Distiller 140 Working with ECM Print Services in ChemStation 142 11 Troubleshooting 143 General Problems 144 Alerts and Error Messages at ChemStation Startup 145 Error Messages in the Spooler Queue Manager 146 6 ChemStation OpenLAB Option Concepts Guide Contents 12 Appendix 149 ChemStation Privileges in ECM 150 ChemStation Roles in ECM 153 ECM related privileges concerning the ChemStation configuration 157 ChemStation OpenLAB Option Concepts Guide Contents 8 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB Option Concepts Guide J 6 eece 1 e Introduction J WhatisECM 10 Add On Solution for ChemStation OpenLAB Option 11 Overview of data related workflows 12 Overview of workflows for methods sequence templates 14 Data Storage in ECM 16 21 CFR Part 11 Compliance 17 This chapter introduces ECM the implementation of OpenLAB Option in ChemStation and the requirements of 21 CFR Part 11 ee Agilent Technologies 1 Introduction What is ECM
85. n see Remote Data Path on page 45 the remote data path can also be set directly in the sequence template This allows to set up different remote paths for each sequence without having to modify the Preferences The Remote Data Path for a sequence template is set up in the Sequence Parameters tab xi Sequence Parameters Sequence Output m Data File M Remote Data Path Path C Chem32 1 DATAS 7 I Use Preferences Subdirectory Path Select Path Auto Prefix Counter fWAD_Support Lab C C Prefix Counter fsi Gi 000001 LC X Data v Part of method to run M Shutdown According to Runtime Checklist z I Post Sequence Command Macro F Use Sequence Table Information z Wait 0 00 4 minutes after loading a new method Not Ready Timeout 0 00 2 minutes p Bar Code Reader Fraction Information F Use In Sequence Fraction Start Location On a bar code mismatch Sequence Comment Figure 8 Sequence Parameters tab of the Sequence Parameters dialog Use Preferences When this checkbox is enabled the Remote Data Path as specified in the Preferences will be used Any LCDF path specified in the Sequence Parameters will be ignored for this sequence When this checkbox is disabled the Remote Data Path will be used as specified when the sequence template is used for data acquisition ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option 3 Path To specify the
86. n FDA terms closed system means an environment in which access is controlled by persons who are responsible for the content of electronic records on the system 11 3 5 The evidence of a system being a closed system is not a one time check but an ongoing process of executing and documenting the system controls that make sure that the system is closed In contrast in an open system those persons being responsible for the content of electronic records do not control the system access As a result open systems require additional encryption technology for all data transfer over the network ChemStation OpenLAB Option is designed for and supported in closed systems ChemStation OpenLAB Option Concepts Guide Administration Regarding 21 CFR Part 11 Compliance 5 Overview of Configuration Steps Required for Part 11 If you want to configure ChemStation OpenLAB Option to be compliant with 21 CFR Part 11 you need to go through the following checklist LCDF structure on the ECM Server prepared according to your needs See Data Storage in ECM on page 16 ChemStation OpenLAB Option installed on the ECM Server See Updating the ECM Database on page 22 ECM Roles Users Groups configured See Configuring users roles and privileges on page 25 ECM Account configuration with active audit trail and mandatory reason See To enable the ECM Audit Trail on page 87 and Account configuration on page 89 Passwor
87. n damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated condi tions are fully understood and met A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indi cated conditions are fully under stood and met For Research Use Only ChemStation OpenLAB Option Concepts Guide In This Guide In This Guide This guide contains installation and reference information for ChemStation OpenLAB Option G2189BA the ECM interface between Agilent ChemStation and an Agilent Enterprise Content Manager ECM client server system 1 Introduction This chapter introduces ECM the implementation of OpenLAB Option in ChemStation and the requirements of 21 CFR Part 11 2 Installation This chapter describes the installation and configuration of ChemStation OpenLAB Option 3 Basic Concepts of ChemStation OpenLAB Option This chapter describes how to log in to ECM in ChemStation and explains the ECM related user interface items and toolbars as well as the main preference settings 4 Working With ChemStation OpenLAB Option This chapter describes the basic workflows with ChemStation OpenLAB Option There are four data related workflows and two workflows for methods and sequence templates
88. ng the ECM users ChemStation Operator and ECM User If you log in to ECM and have been authorized by the ECM system the ChemStation operator name in the sample info when running single samples or the sequence parameters when running a sequence is overwritten by your ECM user name As long a user is logged on to ECM the operator name is given by the ECM logon and cannot be overwritten As soon as you log out of ECM the ChemStation operator name defined by the ECM is removed and is replaced by the entry disconnected While acquiring data to ECM it is not possible either to log in or to log out of ECM This prevents the operator name from being changed during data acquisition ChemStation OpenLAB Option Concepts Guide 39 3 Basic Concepts of ChemStation OpenLAB Option Session lock If you leave the ChemStation computer for a certain period of time you can lock ChemStation so that no other user can access the program This is a safety feature to ensure that there is no unauthorized access to ChemStation When you activate the session lock you or another user must first provide a valid ECM login before continuing to work with ChemStation There are the following options to activate the session lock Privately ECM gt Lock Session gt privately Only the user who activated the session lock or a user with the CS Break Session Lock privilege can log in Non privately ECM gt Lock Session gt non privately Any v
89. ng the user adding new reanalyzed versions to the original raw data General Aspects of Data Security in Computerized Networks Open Versus Closed Systems Before discussing details of data security in a chromatographic system some general aspects of data security in a computerized network need to be considered It is generally known that data transfer over a public network can be accessed by unauthorized external persons hackers who gain access either for personal amusement or intentional fraud If an electronic identification comprising user ID and a password is used to approve confidential or important data users must be sure that their signatures are unbreakably linked to the data and that nobody can copy this signature or get access to the passwords In a public system this would require additional encryption technology for example a private public key combination of data encryption In contrast if a computerized system is protected from unauthorized access users can be sure that their signatures are private and are not accessible to unauthorized individuals The FDA also distinguishes between these two scenarios and defines them as open and closed systems A public network system can therefore only be viewed as an open system and a protected network as a closed system if it fulfills additional requirements ChemStation OpenLAB Option Concepts Guide 81 5 82 Administration Regarding 21 CFR Part 11 Compliance I
90. nt dialog box The Queue Management Details tabs offer two views of the command details Summary tab e Details tab In either tab the tools in the toolbar allow you to navigate through the command details J4 Displays the details of the first command in the list qj Displays the details of previous command in the list Displays the details of next command in the list gt I Displays the details of last command in the list Summary tab The Summary tab gives the following summary information about the selected item Command Description The description of the item Created The date and time when the item was added to the queue Changed The date and time when the item was last processed Last Error A description of the error that caused the item to be added to the queue ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option 3 Details tab The Details tab gives detailed information about the selected item You cannot edit the information in this list The toolbar provides the following tools w Sorts the properties by category ig _ a Sorts the properties alphanumerically This tool is disabled under all circumstances in the ChemStation ChemStation OpenLAB Option Concepts Guide 53 3 Basic Concepts of ChemStation OpenLAB Option Remote Data Path as Sequence Parameters 54 Instead of specifying the Remote Data Path in the Preferences for all acquisition sequences to be ru
91. o ECM before ECM Methods are indicated by Lig ECM sequence templates by 9 in the ChemStation Navigation Pane Select ECM gt Load Method or ECM gt Load Sequence Template respectively to download a method sequence template from ECM If you use one of the Load commands the ECM Desktop Open dialog will open Navigate to the ECM folder to load the method M SSIZIP or sequence template S or S SSIZIP of your choice x Look in datat et i amp oh oY EE 10303 gt 57s 7a i E SSIZIP v Detail E STANDARD_11_S 200 SSIZIP i si STANDARD_11_S 200 SSIZIP Arrange Icons File name STANDARD_11_S 2008 08 26 09 20 13 5C SSlzip Open Files of type SC SSlzip X Cancel Figure 18 ECM Desktop Open dialog If the item is checked out it is marked with a blue or red icon see Figure 18 on page 73 marker 1 blue icon the item has been checked out by you current user red icon the item has been checked out by another ECM user You can load any checked out item However if an item has been checked out by another ECM user the other user must check in the item before you can save it back to ECM ChemStation OpenLAB Option Concepts Guide 73 W 4 wong eh h ChemStation OpenLAB VVOrkK 74 r Methods and Seat npl tes To check out or check in an item you can use the according icons available in the ECM Desktop Open dialog see Figure 18 on pag
92. o the DVD drive 2 In Windows Explorer navigate to the folder diskdrive ECMAPI and double click the file ECMAPIDeploy mci The Agilent OpenLAB ECM API Installation wizard Opens 3 Click Next 28 ChemStation OpenLAB Option Concepts Guide Installation 2 4 Enter User Name and Organization Select the option to install the API for Anyone who uses this computer all users Click Next 5 Select a destination folder where you want to install the ECM API the default folder is C Program Files Agilent Technologies ECM API 1 0 24 1 Click Next 6 Click Install 7 After the installation has completed click Finish To install ChemStation 1 Insert the ChemStation DVD into the DVD drive 2 From the Start menu in the Task Bar select Start gt Run 3 At the command line type diskdrive Setup For example D Setup The setup software checks if the following software components are available Microsoft NET Framework 3 5 SP1 PDF XChange 4 0 4 If there are missing components additional dialogs open to install these components Click Install to install the missing components For the Microsoft NET Framework also read and agree to the License Agreement After the missing components have been installed the Agilent ChemStation Setup Wizard opens 5 Click Next 6 Select the check box to confirm the license agreement Click Next 7 Select a destination folder where you want to install the new ChemStation the default
93. og The default setting for the consecutive signature timeout is 5 minutes Using electronic signatures To apply an electronic signature 1 Right click the required SSIZIP container and select Electronically Sign gt Electronic Signature from the context menu The Electronic Signature dialog opens The other command in the context menu Electronically Sign gt Acrobat Plug In Signature works only for PDF documents and only if you purchased the according plugin It enables you to add signatures directly inside PDF documents 2 Enter your ECM user credentials username password and domain ChemStation OpenLAB Option Concepts Guide Administration Regarding 21 CFR Part 11 Compliance 5 Enter your current location With this information the location from where you provide the signature is reproducible Select a reason for the signature from the Default reason drop down list Or Select the User specified check box and enter a different reason into the text field Note that this option is only available if the ECM Account is configured accordingly Click Sign The file is now signed electronically The e signature is shown in the file properties in the eSig tab The e signature is also included in the ECM Audit Trail To view electronic signatures The user preferences in ECM can be configured in such a way that the number of e signatures applied to a file is shown by default in the ECM content display together with the
94. om the Start menu in the Task Bar select Start gt Settings gt Control Panel gt Administrative Tools gt Computer Management The Computer Management window opens Computer Management SJ Ele ation View window Help e om BaBe I Computer Management Local Name Descriptio E iy System Tools ES Admini Administrators have complete and u E Event Viewer 5 Backup Operators can override secu Shared Folders 3 Guests have the same access as me Local Users and Groups Members in this group can have som Power Users possess most administr awa 3 Members in this group are granted t Supports file replication in a domain Users are prevented from making ac Users of this group may start the Ch Group for the Help and Support Center fi Services and Applications Figure 4 Computer Management window Right click the group CSAdministrator and select Add to Group from the context menu The Properties dialog shows the users who are currently member of the group 34 ChemStation OpenLAB Option Concepts Guide Installation Installation Tasks on the ChemStation Computer CSAdministrators Properties this group may start the ChemStation Administration tool 3 Administrator Remove x cma sory _ 3 Use the Add button to add the required users After confirming with OK the Properties dialog also contains the newly added users ChemStation OpenLA
95. onfiguration Tasks on ECM Server 22 Updating the ECM Database 22 Updating roles in existing ECM Accounts 24 Configuring users roles and privileges 25 Installation Tasks on the ChemStation Computer 27 Preparing the ECM Web Client 28 Installing a new ChemStation with ChemStation OpenLAB Option Adding ChemStation OpenLAB Option to an existing ChemStation Enabling users to start the ChemStation Administration Tool 33 Uninstallation 36 To uninstall Agilent ChemStation 36 To uninstall Agilent ChemStation 36 To uninstall other ChemStation components 36 This chapter describes the installation and configuration of ChemStation OpenLAB Option ee Agilent Technologies 28 32 2 Installation Prerequisites Before you install Agilent ChemStation OpenLAB Option make sure that the following prerequisites are met e The ECM Server software must be installed and configured as described in the Enterprise Content Manager Installation Guide All server related prerequisites as well as the installation and configuration details are described in the guide The ECM versions supported with ChemStation are OpenLAB ECM Workgroup 3 3 1 MS SQL Server 2005 with ECM 3 3 1 Hotfixes 1 5 OpenLAB ECM Enterprise with ECM 3 3 1 Hotfixes 31 45 47 54 56 57 59 and 70 OpenLAB ECM Workgroup 3 3 2 SP1 MS SQL Server 2005 OpenLAB ECM Enterprise 3 3 2 SP1 MS SQL Server 2005 or OpenLAB ECM Enterprise 3 3 2 SP1 Oracle 10 2 0 1 or Oracle database
96. operation ECM asks the user for a reason This reason is also shown in the ECM Audit Trail For automatic uploads there are default reasons given by the system The reason entry may be optional or mandatory depending on ChemStation OpenLAB Option Concepts Guide Administration Regarding 21 CFR Part 11 Compliance 5 the ECM configuration see Account configuration on page 89 If the system is configured to be compliant to 21 CFR Part 11 providing a reason is mandatory To enable the ECM Audit Trail You can enable the ECM Audit Trail only for a complete ECM Account To activate the ECM Audit Trail you must select the check box Enable audit trail for this account when creating a new account There is no possibility to activate the ECM Audit Trail afterwards for an existing account or to deactivate the ECM Audit Trail again If the system shall be compliant to 21 CFR Part 11 the ECM Audit Trail must be enabled To view the ECM Audit Trail for a specific file 1 In ECM right click the respective file and select Properties from the context menu 2 In the File Properties dialog select the Audit Trail tab All actions related to this specific file are listed here together with the date ECM user name who performed the action and a reason provided by the according user To view the ECM Audit Trail for all files 1 In ECM select the Administration page 2 In the Navigation Pane select the Activity Log gt Audit Trail node
97. ou can manage the data transfers from ChemStation to ECM that were interrupted or could not be started for any reason Each failed transfer job is listed in a separate line ioixi D tld lt a 2 Description Error Queued at Last process at Commit Invalid path specified 1429 2009 1 28 PM 1429 2009 1 28 PM The queue already contains items 1 29 2009 2 05 PM 1 29 2009 2 05 PM The queue already contains items 1 29 2009 2 06 PM 1429 2009 2 06 PM The queue already contains items 1 29 2009 2 06 PM 1429 2009 2 06 PM Figure 7 Spooler Queue Manager ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option 3 The following information is provided for each line Description Information on the version of the data that will be transferred Two values are possible Import No older version of the data exists in ECM at this time The data has been newly created and will be uploaded as Version 1 Commit There is already at least one version of the data in ECM The version number of the uploaded data will be increased by one Error Error that disrupted the data transfer For details on the possible errors see Error Messages in the Spooler Queue Manager on page 146 Queued at Date when the unsuccessful transfer was queued in the Spooler Queue Manager Processed last at Date when the transfer was last attempted The toolbar offers you the following commands to manage the
98. perform this task it is required that the original sequence file is still available It must contain all the necessary sequence lines and follow the original data file naming scheme to reprocess all the data files of the sequence In addition all the methods in the Method column of the sequence table have to be available To perform migration start the Sequence Container Migration from the Sequence menu in Data Analysis view t Sequence Container Migration x To migrate non container data to a sequence container select sequence template method path data source and destination directories Select Sequence Template JC Chem32 1 SEQUENCE BATCH S QI Select Method Path fc Chem32 1 METHODS i Select Source JCAChema2 1 DATASDemo S Select Destination Ic Chem32 1 DATA demo_data Messages and warnings Figure 28 Sequence Container Migration Fill in the following required fields see Figure 28 on page 111 Select Sequence Template Select the sequence file S that contains the sequence table that matches the data set to be migrated Select Method Patch Select the directory where the methods are located that are referenced in the sequence table Select Source Select the directory that contains the data files to be migrated ChemStation OpenLAB Option Concepts Guide 111 7 Treatment of ChemStation Legacy Data and Data Migrated from ChemStore Select Destination Specify the path and name of the sequence container to
99. pload the sequence data to ECM before you create a report Only data that is available in ECM can be used by OpenLAB Intelligence Reporter to generate a report ChemStation OpenLAB Option Concepts Guide 125 126 Interface to OpenLab Intelligence Reporter Calculation of performance values In ChemStation certain specific values such as noise and peak performance values are not necessarily calculated and uploaded to ECM If these values are not uploaded to ECM you can not use them in your reports Under ECM gt Preferences there is the check box Calculate Peak Performance This check box is cleared by default If you select Calculate Peak Performance Values such as noise and peak performance values are always calculated They are uploaded to ECM together with the other sequence data You can use the values in your reports If you do not select Calculate Peak Performance Values such as noise and peak performance values are only calculated if you choose the ChemStation report styles Performance or Extended Performance As a consequence there is no guarantee that these values always exist in ECM and you can not generate reliable OpenLAB IR reports containing this type of information ChemStation OpenLAB Option Concepts Guide This chapter provides an overview of the available ECM Attribute Extraction Services AES for ChemStation data The AES extract metadata information ChemStation OpenLAB Option Concepts Guide Att
100. ploaded to the ECM program it must have the file extension pdf ChemStation OpenLAB Option Concepts Guide Using Print Services in ChemStation 10 Setting Up ECM Print Services Installing ECM Print Services The installation and setup of ECM Print Services requires following steps The installation details are given in the ECM Print Services documentation 1 Connect to the ECM Server revision 3 3 1 and select the Administration tab 2 In the Download section of the Administration tab select ECM Print Services for ECM and run the installation Follow the instructions given by the installation wizard 3 After the installation the ECM Print Services icon is available in the task bar and the Amyuni PDF Convert is available as printer see Start gt Settings gt Printers and Faxes gt Amyuni PDF Converter 4 Double click the ECM Print Services icon The ECM Login dialog opens Enter the required user credentials and click Login to proceed for configuration ChemStation OpenLAB Option Concepts Guide 137 10 Using Print Services in ChemStation Configuring ECM Print Services for use with Amyuni PDF Converter 1 Create a monitor folder on your ChemStation ECM Client system The folder should not be placed in the Chem32 directory 2 Right click the ECM Print Services icon in the task bar and select Configure Printers Configure Printers Login Printer Unattended OBE 2 33pm Figure 35 ECM Print Service icon
101. r Transfer protocol HTTP 89 5 90 Administration Regarding 21 CFR Part 11 Compliance Setting Description 21 CFR Part 11 Requirements Lockout Inactivity Timeout System administrator email Minimum Password Length Require entry in Reason fields If a user tries too often to log in with invalid user credentials he is locked out of the system and cannot log in any more not even with valid user credentials You can define the number of allowed login attempts If a user does not perform any action in ChemStation for the given period of time he is automatically logged out The same applies to the ECM Web Client The e mail address you provide here will automatically be notified when a user was locked out after too many unsuccessful login attempts If users change their passwords they must choose a password with at least the given number of characters The default setting is 5 In each ECM Audit Trail or System Log entry the users can enter a specific reason for the action If this check box is selected the entry is mandatory You should limit the number of allowed login attempts to three You should specify a timeout You should provide an e mail address You should require a minimum password length of at least 5 characters The ECM Audit Trail and System Log reasons must be mandatory Users Groups Roles To configure the password settings for an ECM Account a
102. re described in the following Template selection in Sequence Output Under Sequence gt Sequence Output you can select an OpenLAB Intelligence Report Template for the currently loaded sequence This setting is optional e Ifyou select a specific report template When you create a report OpenLAB Intelligence Reporter automatically uses the given report template The resulting report is shown in OpenLAB Intelligence Reporter without any further inquiry If you do not select any specific report template When you create a report OpenLAB Intelligence Reporter opens with the relevant data already selected but without applying any specific report template to the data You must open a suitable report template manually in the OpenLAB IR Reporter Client On an ECM installation with multiple accounts projects from all accounts are visible in the Projects menu of OpenLAB Intelligence Reporter Ensure that you select a project belonging to the ECM Account you are working on This is not an issue when selecting a template directly from ChemStation as you select the template from the LCDF structure of the specific ECM Account you are working on Depending on the options selected in the OpenLAB IR Reporter Client the report is either generated automatically after loading the template or must be generated manually The link to the selected report template is stored in the sequence parameters Thus when you create the report the next time t
103. rences in ChemStation 4 A new version of the data is created in ECM For more details and for additional workflows refer to Data related workflows on page 59 ChemStation OpenLAB Option Concepts Guide 13 14 Introduction Add On Solution for ChemStation OpenLAB Option Overview of workflows for methods sequence templates Workflow 1 Workflow 2 Local Files Save new method ECM Save changed method Method A Method A Method A Method A Version n 1 Workflow 1 Uploading a new method 1 A new method or sequence template is created 2 The method or sequence template is uploaded to ECM using the path selected by the user 3 The version 1 of the method or sequence template is automatically created in ECM ChemStation OpenLAB Option Concepts Guide Introduction 1 Workflow 2 Saving a changed method 1 An existing method or sequence template is loaded from ECM 2 The changed method or sequence template is saved to ECM 3 A new version of the method or sequence template is automatically created in ECM For more details and for additional workflows refer to Workflows for Methods and Sequence Templates on page 70 ChemStation OpenLAB Option Concepts Guide 15 1 Introduction Data Storage in ECM 16 ECM provides a four level data storage model with the structure of Location Cabinet Drawer Folder The Location Cabinet Drawer and Folder names comprise the path name called either LCDF
104. ribute Extraction Services for ChemStation Data Attribute Extraction Services for ChemStation Data 128 ACAML Filter 131 ChemStation XML Attribute Extraction Service 132 ChemStation Filter 133 from the ChemStation data files These metadata make the ChemStation data searchable For detailed information refer to the ECM documentation ee Agilent Technologies 127 9 Attribute Extraction Services for ChemStation Data Attribute Extraction Services for ChemStation Data ECM Attribute Extraction Services AES provides the following AES for the extraction of metadata from ChemStation data files e The ChemStation XML filter extracts peak compound and result data from the result xml file generated by the XML export routine in ChemStation revision A 10 02 and later e The ChemStation filter extracts basic sample and run data from the header of the channel files ch uv and txt files generated by all ChemStation revisions AES need to be installed by an ECM Administrator on the ECM Server in addition the filters need to be enabled for the system The keys of an AES that are to be applied to a ChemStation file need to be selected for the respective LCDF structure These are ECM administration tasks and are described in the Enterprise Content Manager Administrator s Guide and the ECM online help The metadata can be queried using various search types in ECM The ECM Search functionality is also available within ChemStation W
105. roles For detailed information refer to the ECM Administrator s Guide Assigning roles Users do not need any specific role in order to log in to ECM However in order for users to see a particular Location Cabinet Drawer or Folder in the user interface they must have the Reader role as a minimum requirement As a result domain users with no global roles might not be able to view anything in the content unless they were granted the appropriate privileges You should grant the users of the ChemStation OpenLAB Option the Contributor role This can be done at the global level for the entire ECM Account or individually for specific folders see Roles and folders on page 91 The Contributor role allows the ChemStation OpenLAB Option user to view and add content to ECM The Contributor role should be enhanced with the Content Add Folder privilege This allows ChemStation ECM users to add folders to the LCDF hierarchy If the role does not include the Add Folder privilege the users cannot add a new Remote Data Path LCDF in ChemStation In addition to the ECM roles user of ChemStation OpenLAB Option must be assigned at least one of the ChemStation roles or another customized role with according ChemStation privileges You find a complete list of all ChemStation roles and all relevant privileges in the Appendix If a ChemStation user has no ChemStation privileges in ECM this user is not able to work with ChemStation OpenLA
106. s You do not have permission to add files Probable cause Suggested actions 1 You do not have appropriate privileges to Ask an administrator to give you the save files to the specified location in ECM corresponding privileges Unable to upload filename This file is currently checked out to another user and may not be updated error 1 Probable cause Suggested actions 1 Another user has checked out the file The other user has to check in the file before you can upload the file ChemStation OpenLAB Option Concepts Guide 147 11 Troubleshooting Error Messages in the Spooler Queue Manager 148 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB Option Concepts Guide 12 Appendix ChemStation Privileges in ECM 150 ChemStation Roles in ECM 153 ECM related privileges concerning the ChemStation configuration ee Agilent Technologies 157 149 12 Appendix ChemStation Privileges in ECM 150 Privilege Description CS Audit Trail CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS Batch Break Session Lock Calibration Command Line Companion Control Data Data Analysis Diagnostic Full Menu Instrument Configuration Instrument Setup Integration Events lon Labels Logbook Run Enable the audit trail for a specific method Run Enables all operations in Batch view Run Unlock a ChemStation session locked by other users Edit
107. s and Logbooks on page 84 Preferences Paths Signal Review Options Audit Trail Transfer Settings C Enable Method Audit Trail for all methods C Enable Results Audit Trail Cancel Figure 6 Audit Trail tab in the Preferences dialog You can change these settings for all ChemStation instances on the client PC in one single step by using the ChemStation Administration Tool see ChemStation Administration Tool on page 92 Remote Data Path In ChemStation OpenLAB Option the Remote Data Path needs to be specified in order to save the data to the correct location in ECM In the Preferences dialog the Transfer Settings tab see Figure 6 on page 45 allows you to define the Remote Data Path The Remote Data Path reflects the LCDF structure in ECM Server Account In the text fields Server and Account you can specify the ECM Server and ECM Account that you want to use to store the ChemStation data ChemStation OpenLAB Option Concepts Guide 45 3 46 Basic Concepts of ChemStation OpenLAB Option At your first login from ChemStation to ECM you must specify the server and account information You can either enter the information manually or you can click Get Server to fill the fields with the Server and Account where you are currently logged in ChemStation then keeps the Server and Account information for future sessions If you log in to a different ECM Server later you have to update the Server and Accoun
108. stom fields and the according values are then displayed on ChemStation reports see examples below Data File C CHEM32 1 DATA TEST 2008 04 07 16 09 40 002 0201 D 4 7 2008 4 12 16 PM Inj 1 Figure 26 Sample custom fields ChemStation OpenLAB Option Concepts Guide 105 6 Custom Fields Reporting of Custom Fields 0 0000 Biphenyl b gt wi N 0 0000 o Terphenyl 1 Warnings or Errors Warning Calibrated compound s not found Value ee i i i ee ee e i i i i Figure 27 Compound custom fields 106 ChemStation OpenLAB Option Concepts Guide Custom Fields 6 Reprocessing with Custom Fields It is possible to modify the values of the custom fields during reprocessing When you prepare the reprocessing you can edit the custom fields values in the Sequence Table in the Data Analysis view For more information on editing custom fields values see Specifying Custom Fields Values on page 103 After an acquisition you can only edit the values of existing custom fields that is custom fields that were defined in the method used for the acquisition You can not add new custom fields afterwards even if the method used for reprocessing contains different custom fields than the original method ChemStation OpenLAB Option Concepts Guide 107 6 Custom Fields Reprocessing with Custom Fields 108 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB
109. stration Regarding 21 CFR Part 11 Compliance To enable the Results Audit Trail If you enable the Results Audit Trail the relevant changes are tracked for all samples independent of the sequence they belong to and independent of the user who carries out the change 1 Select View gt Preferences 2 On the Audit Trail tab select Enable Results Audit Trail To view the Results Audit Trail for the loaded sample in ChemStation 1 In the Data Analysis view select View gt Current Data File Logbook Report History If you create a ChemStation report you can display the report on the screen send it to a printer or save the report as a specific file report pdf These report outputs may easily be lost or overwritten especially when you create several reports after each other With ChemStation OpenLAB Option ChemStation automatically tracks any report that was generated In order to reproduce an old or overwritten report select Report gt Report History Here you can see all reports created for the current data file since the installation of ChemStation OpenLAB Option You can also export or print this history ECM Audit Trail Audit Trail is a record showing who accessed the system and what operations he or she performed during a given period of time You can view file related system administration folder administration and scheduler related entries For example you can see when a file was added and who added it For each
110. t you must first update the roles in that specific account The new ChemStation roles and their privileges will be available only after updating the roles for the existing account To make the new roles and privileges available in an ECM Account All system roles will be reset to default when performing Reset Role If you made manual changes to a system role these changes will be lost All other roles that were created manually will be deleted Open a browser window and connect to the ECM Web Server Log in to the ECM Account in which you want to update the roles Select the Administration tab Click Account Administration ao A Q N Double click Users Groups Roles The Account Administration dialog opens 6 Select the Roles tab 7 Click Reset Roles ChemStation OpenLAB Option Concepts Guide Installation 2 The default ChemStation roles and the according ChemStation privileges see ChemStation Roles in ECM on page 153 are now available in the current account and can be assigned to the users The default ChemStation roles do not contain any ECM privileges A ChemStation user who wants to access ECM must additionally be assigned the required ECM roles see Assigning roles on page 26 and ECM related privileges concerning the ChemStation configuration on page 157 Configuring users roles and privileges Concept of users roles and privileges In ECM you can either create specific ECM users or oper
111. t information You can click Get Server again to fill the fields with the current ECM Server name and the current ECM Account Path To specify the Remote Data Path you need to select a Location and Cabinet available in the ECM Browser Click Select Path to select the required path in an ECM Explorer dialog If no Remote Data Path is specified a warning message will be shown at ChemStation startup For the Drawer and Folder you can either keep the selected items or you can select predefined tokens for an automatic path creation When you use the predefined tokens in the Remote Data Path the system automatically creates the items if they do not already exist in ECM If you use tokens make sure you have the required ECM privileges to create folders Alternatively another user who has the required privileges can create the necessary folders in advance Alternatively the Remote Data Path can be specified as Sequence Parameter see Remote Data Path as Sequence Parameters on page 54 Uploaded objects can be stored only at the Folder level ChemStation OpenLAB Option Concepts Guide Basic Concepts of ChemStation OpenLAB Option 3 Table 1 Remote Data Path items ECM Data Path Item Convention Location Fixed location to be selected in ECM Cabinet Fixed cabinet to be selected in ECM Drawer Drawer available in ECM Tokens Instrument Name Instrument Number Operator Folder Folder available in ECM Tokens Instrument
112. t is therefore recommended that in an regulated environment ChemStation users work as Windows Users or Powerusers 2 Click Add to add the license key to the list 3 Provide valid license keys accordingly for all of the instruments shown in the list The software automatically recognizes which license is valid for which module 4 Click Next The ChemStation Administration Tool dialog opens ChemStation Administration Tool Figure 3 ChemStation Administration Tool ChemStation OpenLAB Option Concepts Guide 31 2 32 Installation 5 Select or clear the Mandatory Login check box depending on whether the ECM login should be mandatory or optional in ChemStation the settings will be used for all ChemStation instances that are installed on this computer For more details on the login functions see User Permissions on page 38 You do not need to configure the other options in this dialog during the installation You can configure these items anytime in ChemStation see ECM Preferences on page 44 and Audit Trails and Logbooks on page 84 or by using the ChemStation Administration Tool directly see ChemStation Administration Tool on page 92 6 Click OK 7 Click Finish The Configuration Editor opens 8 Proceed now with configuring the instruments To configure instruments You can configure the instruments in the Configuration Editor For details see the manual Installing your ChemS
113. tandards 120 ChemStation OpenLAB Option Concepts Guide 5 Statistical calculations Interface to OpenLab Intelligence Reporter Introduction 6 Results for quality control samples grouped by sample name Column Check and Usage Report Creation Date 5 20 2008 10 46 34 AM Report created Start Date 7 20 2006 Column Name SB C18 Column Serial No USWEX01247 Column Lenght 50 a Total of Injections of Injections 705 252 Column Name Zorbax C18 Column Serial No AD6789X5 Column Lenght 250 Total of Injections ee ZorbaxSB C18 uswex012 Column Name Column Serial No Column Lenght Total of Injections 50 ee Chromatographic Column Check and Usage Report 5 20 2008 10 46 34 AM End Date Instrument Name Instrument 1 Agilent Technologies 5 20 2008 Figure 31 1 2 Interactive column usage report User parameters here Start Date and End Date as selected by the user Expandable detail information ChemStation OpenLAB Option Concepts Guide 121 8 Interface to OpenLab Intelligence Reporter Introduction Calibration Standards Statistics Report Creation Date 5 2 2008 5 03 48 PM Calibration Level 1 Agilent Technologies Sequence Name Sample Cal Lvl RT Area Height Amount RF Name E LIR 2007 2 2007 02 28_09 54 30 Standard L1 1 088 08 0 424 0 815 1 501627 Standard L1 1 09 06 0 436 0 8487 14754361 O Standard L1 1 09 05 0 414 0 8136
114. tation After the successful installation ChemStation contains the new ECM menu and a number of other ECM interface elements see Overview of new interface elements on page 41 Adding ChemStation OpenLAB Option to an existing ChemStation To add ChemStation OpenLAB Option subsequently 1 From the Start menu in the Task Bar select Start gt All Programs gt Agilent ChemStation gt Add instrument The Setup Wizard Instruments dialog opens see Figure 2 on page 30 2 Under General Addon products select the ChemStation OpenLAB Option check box 3 Click Next The Setup Wizard Licenses dialog opens ChemStation OpenLAB Option Concepts Guide Installation 2 4 Enter a valid license key for ChemStation OpenLAB Option in the input field at the bottom 5 Click Add to add the license key to the list 6 Click Next The ChemStation Administration Tool dialog opens see Figure 3 on page 31 7 Select or clear the check box Mandatory Login depending on whether the ECM login should be mandatory or optional in all ChemStation instances on this computer 8 Click OK 9 Click Finish The Configuration Editor opens As you have already configured the instruments and have now added the OpenLAB Option you can exit the Configuration Editor without any further actions 10 Prepare the ECM Web Client and install the ECM API as described in Preparing the ECM Web Client on page 28 Enabling users to start the ChemStation Adm
115. ted by the ECM system Login is aborted and there will be no access to the ECM functions in ChemStation all ECM related menu items will be grayed out For further troubleshooting please contact your ECM administrator ECM Server is not available after login If the ECM Server connection is interrupted after login to ECM from ChemStation the user has been authenticated by the ECM system In this case ChemStation knows the current logged in user When the ECM Server becomes unavailable ChemStation automatically tries to reestablish the user login The ECM Load and Save functions are accessible but an alert informs the user about the interrupted connection to the ECM While acquiring data the automatic transfer of data to ECM cannot be completed The user is notified by an error message and must manually upload the data as soon as the connection is reestablished ECM gt Manage Queue As soon as the ECM Server is available again all ECM tasks are available without restarting the application A new login is not required For further troubleshooting please contact your ECM administrator ChemStation OpenLAB Option Concepts Guide Troubleshooting 11 Alerts and Error Messages at ChemStation Startup Your Transfer Settings Remote Data Path seems to be set to default At every startup Agilent ChemStation checks whether all necessary information is provided for transferring data to ECM This message is shown if the Remote Data
116. th the path is shown as a tooltip of the method sequence template in ChemStation The version number is automatically increased by one Updating the Local Master Method or Sequence Template If a master method or sequence template is updated in ECM i e a new version is created it is possible to update the local copies with the following update procedure 1 Make sure the master method or sequence template to be updated is currently not loaded The currently loaded method or sequence template is not available for update 2 Select ECM gt Update Methods or Update Sequence Templates Update from ECM xj 2 1 METHODS METHOD1 M Cc 32 1 METHODS METHOD2 M C Chem32 1 METHODS METHOD3 M vmli1 support WAD_Support Lab C LC data2 ME THOD3 M SSizip 2 C Chem32 1 METHODS METHOD4 M vmilil support WAD_Support Lab C LC data2 METHOD4 M SSlzip 1 Figure 21 Update Methods dialog box The Update from ECM dialog box is displayed The dialog box lists all methods that are connected to ECM The following columns are available 76 ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB Option 4 Name Path and Name of the local copy of the method sequence template ECM Information ECM server account information and LCDF path of the file in ECM Locally Modified A check box indicating whether the local copy was modified Local Version Version number of the local copy of the metho
117. thod Properties X CS Print Report X CS Report Layout X CS Report Template X CS Sequence X CS Transfer Preferences X ChemStation OpenLAB Option Concepts Guide 153 12 Appendix 154 Table4 Default CS Analyst privileges Privilege Edit Delete Add Run CS Batch X CS Calibration X CS Control CS Data X CS Data Analysis CS Full Menu X CS Instrument Setup X CS Integration Events X CS Logbook X CS Manual Integration X CS Method X X CS Method Properties X CS Print Report X CS Recalibration X CS Report X CS Report Layout CS Report Template X CS Reprocess X CS Run X CS Sequence X X CS Sequence Summary X CS System Suitability X ChemStation OpenLAB Option Concepts Guide Table 5 Default CS Lab Manager privileges Appendix 12 Privilege Edit CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS cs cs Audit Trail Batch Break Session Lock Calibration Command Line Companion Control Data Data Analysis Diagnostic Full Menu Instrument Configuration Instrument Setup Integration Events Logbook Manage Transfer Queue Manual Integration Method Method Properties Print Report Report Report Layout Report Template Reprocess CS lt xX XxX x ChemStation OpenLAB Option Concepts Guide 155 12 Appendix 156 Table5 Default CS Lab Manager privileges Privilege View Edit
118. to sign electronically This privilege is for example assigned to the ECM default role Approver Reasons for the signature With each signature the ECM users must either select a given reason or if they are allowed to provide their own reason To configure the reasons for signatures 1 In ECM select the Administration page 2 In the navigation pane select the Account Administration node 3 Double click the Electronic Signature item ChemStation OpenLAB Option Concepts Guide 95 5 96 Administration Regarding 21 CFR Part 11 Compliance The Account Administration dialog opens 4 To provide a new reason enter the required text into the Reasons field and click BI 5 To delete an existing reason select the reason in the Default reasons list and click x 6 Ifyou want to allow users to provide their own reason with a signature select the User can specify reason check box If you clear this check box the users can only select one of the given default reasons 7 If necessary adjust the timeout settings The Signature screen timeout defines how long an e signature dialog will stay open if no signature is submitted The default setting is 5 minutes The Consecutive signature timeout is relevant if an ECM user carries out several successive e signatures If the next e signature takes place within the given timeout interval the location and the reason provided in the first e signature will be pre filled in the next dial
119. ty Guide Acquisition for example instrument name method information Chromatogram for example derivative order detector name Custom Module Peaks for example peak name amount retention time compound name Sample for example calibration method LIMS ID Signal noise ChemStation OpenLAB Option Concepts Guide Attribute Extraction Services for ChemStation Data 9 ChemStation Filter The AES for ChemStation extracts attributes from ch uv and txt files created by the 16 Bit ChemStation Rev A x x or 32 Bit ChemStation Rev B x x It extracts key information from the header of ChemStation ch and uv data files for example sample name method file instrument model From the report txt file it extracts key information for example sample name acquisition method analysis method In addition the service extracts information on support files from the category Content An ECM Scheduler Add in for Agilent ChemStation enables the ECM Scheduler to automatically upload data generated by ChemStation to ECM ChemStation OpenLAB Option Concepts Guide 133 9 Attribute Extraction Services for ChemStation Data ChemStation Filter 134 ChemStation OpenLAB Option Concepts Guide ChemStation OpenLAB Option Concepts Guide 10 Using Print Services in ChemStation ECM Print Services 136 Setting Up ECM Print Services 137 Installing ECM Print Services 137 Configuring ECM Print Services for use with Amyuni PDF Convert
120. u confirm this dialog the changed data is uploaded as Version 2 to ECM A local copy of the changed data remains on the ChemStation computer ChemStation OpenLAB Option Concepts Guide 63 4 Working With ChemStation OpenLAB Option For both versions the one after acquisition and the one from the parallel offline review the ECM operator is the user who has run the acquisition even if another user has performed the review in the Offline ChemStation Workflow 3 Reprocessing data and automatic upload Workflow 3 Reprocessing Modifying Upload Figure 11 Reprocessing data and automatic upload 64 ChemStation OpenLAB Option Concepts Guide Working With ChemStation OpenLAB Option 4 The workflow Reprocessing data and automatic upload see Figure 11 on page 64 illustrates how data is reprocessed and then automatically uploaded This workflow applies to data that has been previously stored in ECM A new version of the data is created in ECM for the reprocessed or changed data To save data to ECM automatically after reprocessing 1 Log in to ECM in ChemStation online or offline 2 Select ECM gt Load Data to download a sequence from ECM The ECM Desktop Open dialog opens Navigate to the ECM folder to load the data of your choice and select one of the following packaged files e Single run data D SSIZIP files e sequence data SC SSIZIP files x Look in datat Tags amp aoe 10303 gt 1 E STANDARD_11_S 200
121. uence the privileges of the ChemStation users are now unlimited The users have access to all ChemStation functions Break Session Lock If you select this check box a locked ChemStation can be accessed by any user just by clicking Cancel in the Login dialog If a ChemStation is currently locked and the ECM Server is down selecting this check box is the only possibility to regain access to the current ChemStation session Be aware that as a consequence the user who regained access to ChemStation now has unlimited access to all ChemStation functions The following check boxes allow you to configure the timebased session lock and the ChemStation toolbar Lock Button Timebased session lock locks private If you select this check box the time based session lock will lock the ChemStation sessions privately Otherwise the timebased session lock will be non private ChemStation OpenLAB Option Concepts Guide 93 5 Administration Regarding 21 CFR Part 11 Compliance Toolbar Lock Button locks private If you select this check box the ChemStation toolbar lock button will lock the ChemStation session privately Otherwise a non private lock will be applied Data Handling and Audit Trail Configuration The ChemStation Administration Tool offers to conveniently configure all ChemStation instances on a client at the same time with the same settings By default the option Use instance specific settings is selected so that the settings are
122. w New command Enable Audit Trail New fields on the Sequence Parameters tab Remote Data Path New fields on the Sequence Output tab OpenLAB Intelligence Reporter Template New command Report History New tabs in the Preferences dialog Transfer Settings Audit Trail Completely new menu Shortcuts to several commands of the ECM menu ecm a By g E Path WAD_SupportiLab CILC d LCDF info aA j LCDF Laboratory 1 ChemS See Method Audit Trail on page 84 See Remote Data Path as Sequence Parameters on page 54 See Template selection in Sequence Output on page 124 See Report History on page 86 See ECM Preferences on page 44 and Audit Trails and Logbooks on page 84 See The ECM menu on page 42 LCDF info in the Data Analysis view shows the LCDF path of a file that has been stored to ECM LCDF info in the Method and Run Control view drop down list showing the last ten LCDF paths as defined in the Preferences if the automatic upload After Acquisition is selected ChemStation OpenLAB Option Concepts Guide 41 3 Basic Concepts of ChemStation OpenLAB Option Menu New elements Description ECM related details in the System Diagram in Method and Run Control view classic UI only Completely new details view ECM LCDF WAD_Support Lab CSLC data2 Operator MEYER STEFAN 4 Germany ex1 Automatic transfer after
123. y can decrease its data output on paper speed up the data review and approval process and benefit from new automation technology based on computerized system control for example in manufacturing or dissolution drug release testing In addition to this rule on electronic records other general requirements for computerized systems are brought to the auditor s attention These rules cover the basic requirements of validation which are limiting data access and ensuring data integrity and data traceability It is of course the industry that must ensure that its work practices support the FDA rules but most of the requirements also affect the chemical analysis systems and suppliers of these systems ChemStation OpenLAB Option Concepts Guide Administration Regarding 21 CFR Part 11 Compliance 5 21 CFR Part 11 Requirements To fulfill the FDA rules and guidelines for compliant electronic records and computerized systems it is important to understand the basic aspects of secure data handling e Data security physical protection of data by limiting access to the system and preventing unauthorized access Data integrity protecting raw data and metadata and preventing these from unauthorized modification and linking raw data and results to reproduce the original results at any time for example in an audit situation and document each new result copy e Audit traceability documenting who did what to the results and when and traci