Home

Agilent Upgrade Program V550 Series Pumps vs V551M Series Pumps

image

Contents

1. NOTICE This document contains references to Varian Please note that Varian Inc is now part of Agilent Technologies For more information go to www agilent com chem AES Agilent Technologies vacuum technologies UPGRADE PROGRAM V450 Series Pumps vs V551M Series Pumps Technical Memo Technical Memo 1 V450 450A vs V551 INDEX Outline drawings ISO160 Technical Specification Technical Advantages Accessories Controller comparison Technical Memo V450 450A vs V551 Outline Drawing ISO 160 VIEW A VIEW A ac Dimensions 2 15 801 VIEW B C INCHES Technical Memo 3 V450 450A vs V551 Replacement Suggested VIEW FROM A 7 1 180 0 SO 160 157 1 m l Port Monit r Port E 64 5 1 0 urge 8 0 203 7 Port Q m rir d f f f I I i N ae _ ee I j Ee 47 8 1 Technical Table V450 ISO160 V551 ISO160 V450A ISO160 Total height 370 00 255 00 303 00 Vent port height from bottom 123800 15830 18100 Foreline port height fm bottom 13950 6000 72 50 Venthradpot KFlO M8 KIO Pugetread NA suMi2 KFI6 Waterfit ingthread 2riffled nozzles I 8G 2 riffled nozzles Inlet flange ISO160 ISO160 ISO160 Foreline Flange KF40 KF40 Vent port position referring to Fo
2. 5 Vdc 5 12 24Vdc Remote START signal 1 9 5 Vdc 6 13 24 Vdc FAULT signal 2 10 N O contact 24Vdc Remote NORMAL SPEED 11 3 open collector transistor NOTE Considering the incompatibility of the I O devices the customer can use the adapter box pn 9699859 that will reproduce the input output signals where an interface between the existing system and the new controller Rack Type was used Technical Memo 11 V450 450A vs V551 On V551 Navigator on board controller all signals are available on the same connector J5 qe T mem T pamome D mo T a D N N N I I I I SPEED SETTING SOFT START I I SOFT START I PROGRAMMABLE ANALOG SIGNAL O e GROUND OU 1 1 O O O O O 1 1 1 UT 0 UT UT 2 UT 3 UT 4 UT 15 T e PROGRAMMABLE ANALOG SIGNAL No adapter box is available from existing I O devices to the navigator ones For signal complete description please refer to instruction manual Main cable is supplied controller to pump cable is supplied Technical Memo 12 V450 450A vs V551
3. ases 600 Hz 54 Vac three phase 700 Hz Technical Memo 6 V450 450A vs V551 Technical Advantages The major technical advantage of the V551 is the higher and newer technology of the turbo pump the better vacuum performances the presence of MacroTorr stages that allow a higher foreline pressure Furthermore the V551 has a more robust design an improved efficiency motor and the possibility of mounting the MoniTorr the autodiagnostic system that continuously monitors the pump s operating parameters and informs the service personnel about the state of the pump ensuring maximum vacuum system uptime The inlet flange has not changed ISO160 as the existing V450 series pump the foreline flange of the V551 requires an adapter to NW40KF The water cooling fittings have changed two water cooling kit are available either 9699337 or 9699347 please contact our Tech Support Office The controller is not compatible and must be exchanged This is available in 2 versions Navigator on board or Rack controller in both cases it s much more easier to see the pump operating parameters as current and power consumption furthermore the on board version offers as standard the serial communication RS232 485 contact Tech Support for more details The V551 pump can be installed in any orientation Accessories 1 The fan and the water cooling kits for the V450 450A are not compatible with the new V301 Pump they must be replaced
4. ller this interface can still be used thanks to the adapter box pn 9699859 Contact Technical Support V551 Navigator on board controller The V551 Navigator on board controller is more compact than any other controller furthermore it can be easily installed and disinstalled from the pump it can be either mounted on the bottom or on the side of the turbo pump using the dedicated bracket it offers as std both serial communication options RS232 and RS485 it offers the communication via Navigator Software Contact Technical Support for parameters setting and downloading through a PC The V551 Navigator on board controller offers more features in the I O signals if compared to the previous V450 controller it s easy to use with the new concept plug and pump Technical Memo 8 V450 450A vs V551 Outline 9699442 9699542 10 315 ETE 12 4 Dimensions 21 inches Outline 9699444 9699544 213 00 2 39 16 00 0 59 21100 E 31 DIMENSION mm pinches Technical Memo 9 V450 450A vs V551 V551 Navigator on board 254 76 V450 450A vs V551 10 Technical Memo Interconnection schematic V450 V550 rack Accessories and Option interconnections 1b 3a 3b 3a 2b 2a 120 Vac 1 A forepump vent valve fan etc 120 Vac 0 4 A fan on P6 24 Vdc Analog output voltage 15 8 0 1 Vdc proportional to 4A 1 Vdc proportional to 1A LOW SPEED signal 7 6
5. please contact the Tech Support Office 2 The vent valve 9699843 or the old one 9699833 has not changed if Rack controller willl be used it has changed if the V301 on board controller will be used new pn 9699834 3 Vent port has changed from KF10 to M8 thread anyway an optional vent flange is available pn 9699108 4 Inlet screen has not changed DN160 old pn 9699303 new pn 9699304 5 Purge port is now available with M12 thread a KF16 purge flange is available as option please contact the Tech Support Office 6 Forcontrollers please refer to following section Technical Memo 7 V450 450A vs V551 Controller Comparison V450 controllers 9699442 9699542 are not able to operate the V551 pump it must be exchanged This is available in 2 versions either Y2 Rack V550 pn 9699444 9699544 or Navigator on board pn 9698976 V550 Rack controller The V550 Rack controller has a multifunction alphanumeric display for pump status and error code diagnostic at any time during the pump operation the speed current power and bearing temperature can be displayed remote operation can be accomplished with logic level contact closures and with optional computer interfaces Improved logic output interconnections the V550 controller offers also the possibility to operate via computer with RS232 485 communication kits optional please contact Tech Support Office If the customer was using the remote I O devices on the old V450 contro
6. reline Flange 180 Purge port position referring to Foreline Flange N A 102 DWGN A Technical Memo 4 V450 450A vs V551 Technical Specification Pumping Speed Curve V450 ISO160 Pumping Speed tis 500 10 Hi Vac Pressure mbar V551 ISO160 Pumping speed l s 300 100 10 10 10 10 10 40 10 Inlet pressure mbar Technical Memo 5 V450 450A vs V551 Technical Specifications V450 V450A V551 Connection nominal diameter Inlet ISO160 Outlet NWAOKF NW25KF Pumping speed l s 550 600 510 Compression ration for N2 1x10e 9 17x10e 9 He 2x10e 4 1x10e 7 H2 1x10e 3 1x10e 6 Max Forevacuum pressure mbar N2 18 Gas Throughput mbar l s N2 No limit No limit He No limit No limit H2 No limit No limit Recommended baking pump Diaphragm DS402 Rotary SD300 Triscroll 300 Dry Ultimate pressure mbar With rotary 5x10e 10 lt 1x10e 10 With dry 5x10e 9 Rotational speed 36000 42000 W Cooling Forced Air Forced Air Optional Water Optional water Coolant water Flow 30 I h 0 09 GPM flow 200 I h 0 89 GPM temperature temperature 10 C to 30 C 10 C to 30 C pressure 2 to 4 bar pressure 3 to 5 bar Power consumption 320 325 with water cooling 220 with air cooling Vibration level lt 0 02 um at inlet flange lt 0 01 um at inlet flange displacement lt 50 dB A at 1 meter 45 dB A at 1 meter Motor technology Asynchronous 54 Vac three ph