Home

7535/7530 Hand-Held Computer User Manual

image

Contents

1. Parameter E1022 Optics 645 nm visible red top LED Bright and sharp scanning line Sensor CCD linear image sensor Scan Rate 270 scans s auto adaptive Scan Angle 48 Skew and Pitch 35 Min x Dimension Down to 0 05 mm 2mil Depth of Field 0 to 49 2 cm 19 4 Bar Code Width up to 18 cm 7 on 0 3 Print Contrast Down to 20 UPC E amp A EAN Code 39 Code 128 UCC EAN Solos 128 ISBN Interleaved Matrix Industrial and Stan dard 2 of 5 Codabar Code 93 MSI Plessey Telepen Others including ISBT on request Laser On Time Aim Duration Power Mode Trigger Programmable Mode Bi directional Redundancy Symbology Parameters types lengths Data formatting Serial Parameters Beeper Tone Scan Angle Interfaces Decoded RS232 TTL a Works in any lighting euler conditions from 0 to 100 000 lux Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 25 to 70 C 11 to 160 F Humidity 5 to 95 non condensing Voltage SVDC 5 Power Current 140 mA typical Standby current 40uA Shock Withstands multiple 1m 3 drops on concrete Figure 8 7 1022 Decoded ID Imager Scanner Psion Teklogix 7535 7530 Hand Held Computer User Manual 363 Chapter 8 Specifications Depth Of Field E1022 8 9 5 1 Depth Of Field E1022 Bar Code Width Max Distance nax Beane on mm mil cm inch cm inch 0 1 4 16 2 6 4 23 0 9 0 0 2 23 0 9
2. Statistic Description Channel quality See the description of the Channel Switch Speed parame cq ter in the channel tab for more information on how cq affects channel switching see Channel Switch Speed on page 141 ch Current channel Monitor state of RF Link LOCKED 0 LOCKPENDING 1 LOWC di QWAIT 2 SCANNING 3 STARTUP 4 ABANDON 5 rm Number of received messages complete application messages xm Number of transmitted messages complete application messages rf Number of received polls with attached message xf Number of transmitted frames ra Number of received radio link aborts xi Number of transmitted radio link initialization messages rp Number of received polls xr Number of transmitted retries pt Number of poll timeouts xe Number of transmitted errors rssi Received Signal Strength Indicator Table 5 1 Protocol Statistics Descriptions 138 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 5 Configuration Info Tab Low Level Screen Tap on the Low Level tab to display the Low Level statistics screen Statistics x Protocol Low Level 4lvl 19200 450 20 2 RxOk O RxHd 0 RxBd O RxEr 0 RxOv 0 TxOk 0 TxER Oech et Coll O TxD 0 Figure 5 63 Low Level Statistics Screen Table 5 2 defines the elements of the Low Level statistics screen Statistic Description RxOk Message buffers discarded due to lack of available
3. 5 12 5 5 Modem Information 88 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 5 Configuration Remote Desktop Connection 5 1 Remote Desktop Connection Remote Desktop Connection is a 7535 7530 application used to connect to a Windows Terminal Server so that you can run a session on the Server machine using the 7535 7530 Windows CE NET device Refer to the following website for step by step information about setting up this connection http www microsoft com WindowsXP pro using howto gomobile remotedesktop default asp 5 2 Pocket PC Compatibility The 7535 7530 supports the AYGShell API set that allows Pocket PC compatible applications to run on the hand held Windows CE NET 4 2 is designed to include application programming interface API compatibility support for the Microsoft Windows Powered Pocket PC 2002 shell in units running Windows CE NET 4 2 The website listed below describes the APIs exposed through AYGShell and the application compatibility between Windows Powered Pocket PC 2002 based applications and Windows CE NET 4 2 based devices http msdn microsoft com library default asp url library en us dncenet html WINCENET_CEPCC_App asp 5 3 The Control Panel The Windows CE NET Control Panel provides a group of icons through which you can set a variety of system wide properties such as mouse sensitivity network configuration and the desktop color scheme NN
4. the cursor position determines the end of the string that can be transmitted to the host or transferred to the console or serial ports When enabled set to Y the cursor position is ignored EOL chars This string entry parameter specifies a string of up to 8 characters that are sent after each line in a block transmission If the parameter is not used the rules specified in Transmitted Data Stream are used to determine end of line characters EOB chars This string entry parameter specifies a string of up to 8 characters that are sent after each block transmission Psion Teklogix 7535 7530 Hand Held Computer User Manual 279 Chapter 6 Tekterm Application Kbd Modes 6 19 1 4 Kbd Modes 05 Kbd Modes Range Arrow mode cursor cursor field Echo mode Smart Smart Local Host DEL key DEL DEL BS Clear BKSP key BS BS Clear DEL PrintScreen key 16 1 255 Xmit Enter Y Y N Insert N Y N Newline N Y N Disable kbd N Y N DEC Cursor Keys cursor mode see text Arrow mode This parameter determines whether arrow keys move the cursor within a field or between fields When set to field pressing an arrow key causes the cursor to move to the next field in the direction of the arrow When set to cursor pressing the lt LEFT gt and lt RIGHT gt arrow keys move the cursor within the current field Echo Mode This parameter selects echo mode for the 7535 7530 The available modes are
5. Psion Teklogix 7535 7530 Hand Held Computer User Manual 105 Chapter 5 Configuration Scancode Remapping If the scancode is remapped to a function or a macro the first and second columns remain blank while the third column contains the function name or macro key number e g Macro 2 Adding A Remap To add a new remapping Choose the Add button at the bottom of the dialog box The Remap Scancode dialog box is displayed Scancode Label Virtual Keys BACKSPACE TAB CLEAR RETURN CAPITAL Virtual Key O Force Shifted O Function O Force Unshifted O Macro No Force gt MAO Figure 5 15 Remapping A Key Type the scan code in hexidecimal in the field labelled Scancode The Label field displays the default function of the scancode you are remapping Virtual Key Function And Macro The radio buttons along the side of the dialog box allow you to define to what the scan code will be remapped Virtual Key Function or Macro 106 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 5 Configuration Scancode Remapping When Virtual Key is selected you can choose to force lt SHIFT gt to be on or off when the virtual key is sent If No Force is selected the shift state is dependent on whether the shift state is on or off at the time the virtual key is sent When Function is selected a list of valid functions appears in the dialog box When Macro is selected the macro keys available on
6. A medium Phillips head screwdriver 2 1 2 Charging The Battery AN Important The 7535 7530 uses a high capacity Lithium Ion battery It is crit ical that you review the battery safety guidelines in Lithium Ion Battery Safety Precautions on page 323 before charging the battery Batteries shipped from the factory are not charged They must be fully charged prior to use Full capacity may not be reached until at least 5 full charge discharge cycles have been performed Batteries can be charged using a gang charger or the unit s internal charger When using the internal charger a suitable power source is required All chargers and docking stations are described in Chapter 7 Peripheral Devices amp Accessories beginning on page 321 A Important For 7535 hand helds updating software to PCON version 100835C1 or later automatically resets the battery s parameters The battery gauge will display 0 capacity only until the battery is recalibrated However the operator can safely use the battery because a low battery warning based on voltage at approxi mately 6 8 volts will be displayed allowing sufficient time to change the battery Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 2 Basic Checkout Attaching Carrying Accessories Regarding battery calibration keep in mind that all types of battery chargers available for the 7535 contain single discharge circuits so that only one battery can be calibra
7. Local Host and Smart Local Host Smart In this mode any character entered using the keyboard is displayed before being sent to the host Certain keys cause additional action at the 7535 7530 as shown in Table 6 4 on page 281 In this mode the hand held computer sends all keyboard entries to the host and displays only data received from the host This mode reduces or eliminates the delay between typing a character on the keyboard and displaying the character echoed by the host computer The 7535 7530 displays all printable characters on the screen before sending them to the host The hand held com pares the characters echoed by the host to the characters placed on the page and fixes the display if the host echoes are different The maximum number of characters waiting for echo is 25 Any additional characters are sent to the host but not displayed When the 7535 7530 is in insert mode smart echo is disabled 280 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 6 Tekterm Application Kbd Modes Key Function In newline mode this key moves the cursor to the first ENTER column of the next line In line feed mode this key moves the cursor to column one of the current line CTRL G Bell The 7535 7530 beeps CTRL H Backspace The cursor moves back one space CTRL I Tab The cursor moves to the next horizontal tab stop CTRL J Line Feed CTRL L Form Feed CTR
8. This parameter controls the maximum gap time in milliseconds for a double click If the time between the first and second clicks of the scanner trigger is within this time it is considered a double click The allowable range is 0 to 1000 A value of zero disables this feature A double click produces different results depending on whether or not a value is assigned in the Click Data parameter When a value is not assigned for the Click Data double clicking the scanner trigger overrides the target dot delay set in the Dot Time parameter and initiates a normal scan sweep If a value is assigned for the Click Data parameter double clicking the scanner trigger inserts the Click Data value rather than initiating a scan Click Data For both integrated and external scanners this parameter determines which character is sent to the application installed in your 7535 7530 following a double click A dialog box appears asking that you press the key you want to insert The ASCI Unicode key value of the keypress is displayed Pressing the lt ESC gt key in this dialog box resets the data to zero Psion Teklogix 7535 7530 Hand Held Computer User Manual 191 Chapter 5 Configuration Options Tab Display Parameters Scan Result When this parameter is enabled the type of bar code and the result of the scan appear on the screen Note that this information is only displayed after a successful decode and is visible
9. This parameter determines the time in seconds between the 7535 7530 unlocking and the next transmission of the function key specified by the above parameter A value of zero disables auto reply mode 6 19 2 5 Features r 05 Features Range Printer Y Y N Binary print N Y N Queuing Y Y N Lcl Process Y gt see text Send Mile N Y N Next X N Y N Kbd Locked N Y N Remap Passthru N Y N Disable Beep N Y N Serial gt see text Printer This parameter enables and disables the pins in the serial port used for printers or other external devices Binary print When this parameter is enabled set to Y the page displayed on the 7535 7530 computer is spooled as is except for trailing white space removal When disabled set to N each line of the page displayed on the hand held is preceded by a linefeed LF and followed by a carriage return CR Queuing This parameter enables and disables queuing mode see Queuing Mode on page 236 It also enables TESS procedures to be loaded into the 7535 7530 This parameter should be enabled if local procedures and the ability to switch between hosts within a TESS session are required Changes to this parameter take effect only after the 7535 7530 is reset 292 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 6 Tekterm Application Features Lcl Process Save on Reset The menu item Local Process has a sub menu attached
10. lt CTRL gt lt ALT gt lt BLUE gt and lt ORANGE gt are modifier keys that have onscreen indicators to show when a key is active or locked If a modifier key is pressed once to activate it the key is displayed in the taskbar in lowercase characters for example pressing the lt BLUE gt key once displays blue key in the taskbar If a 50 Psion Teklogix 7535 7530 Hand Held Computer User Manual al gs Chapter 3 Getting To Know Your 7535 7530 Onscreen Indicators modifier key is pressed twice it is locked on and the onscreen indicator is displayed in uppercase letters in the taskbar for example pressing lt BLUE gt twice displays BLUE KEY in the taskbar Battery Gauge The battery shaped icon displayed in the taskbar provides a visual indication of the remaining battery power The icon acts as a meter that is either full at three quarter level half quarter level or empty When the battery level is low approximately 15 minutes from empty a warning window pops up When the battery power is completely depleted a final warning window indicates that the 7535 7530 will be powered down If the 7535 7530 is using external AC power an AC icon is displayed in the taskbar al a o ad al gt Full 15 50 25 Empty AC Connection Battery Charge The battery charge icon is displayed in the taskbar when the hand held battery is being charged 802 11 Radio Signal Quality Increasing radio signal quality is
11. 1 1 2 Using The Combo Dock e Gently slide the 7535 7530 into the cradle portion of the combo dock until lightly latched The 7535 7530 detects combo dock and displays the appropriate icon The battery charge LED lower right LED on the 7535 7530 lights up to show it has external power and may start charging the battery Interaction with the 7535 7530 while in the combo dock is a function of the user application software used to communicate with the host network 1 7 3 Network Access The combo dock includes a dedicated USB to Ethernet converter This USB converter appears as a USB slave to the 7535 7530 USB host controller The 7535 7530 automatically detects insertion into a combo dock and loads the appropriate drivers to communicate with the USB Ethernet converter See Network Addressing on page 334 for details about network addressing issues with the combo dock 332 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 7 Peripheral Devices amp Accessories Troubleshooting 1 1 4 Troubleshooting Troubleshooting issues for the combo dock are identical to those of the quad dock Refer to Troubleshooting on page 335 for helpful tips 1 8 Quad Dock E Note The quad dock is shipped with a user manual It is critical that this man ual be reviewed for additional information and updates The Quad Dock permits each of four docked 7535 7530 hand helds to communicate with a 10 100 BaseT Ethernet network at
12. 2 5 to 5 1 cm 2 5 to 8 cm 2 to 10 cm 1 5 to 11 cm 0 5 to 14 cm Artificial light 1200 ft candles Sunlight 8000 ft candles 4 VDC to 14 VDC Undecoded 75 mA 5 VDC 368 Psion Teklogix 7535 7530 Hand Held Computer User Manual Idling current low power mode Environmental Temperature Rating Humidity Shock at 23 C Vibration Water and Dust Decoding Capabilities Auto discriminates between Safety Regulatory Electrical Emissions Laser Classification Chapter 8 Specifications RD7950 Integrated UHF RFID Reader 7535 Only Decoded 100 mA 5 VDC lt 50 uA 5 VDC Operating 22 to 122 F 30 to 50 C Storage 40 to 158 F 40 to 70 C 5 to 95 NC Withstands multiple 6 foot drops to con crete Meets MIL STD 810E IEC529 rating IP54DW UPC A E EAN8 13 JAN8 13 P2 P5 Code 128 EAN add ons Code 128 MSI Plessey Code 39 Interleaved 2 of 5 Code 39 Full Ascii Standard 2 of 5 Code 93 Codabar Complies to Gost R TUV UL cUL Complies to FCC A EN55022 B BCIQCNS 13438 AS NZS3548 VCCI B IEC 60825 1 1993 A1 1997 A2 2001 CDRH 21 CFR 1040 Class II 8 11 RD7950 Integrated UHF RFID Reader 7535 Only Technical Specifications Frequency Range Transmitter Power Output Channel Spacing Channel Bandwidth Number of Hops Data Rate Input Voltage Current Rating Psion Teklogix 7535 7530 Hand Held Computer User Manual 902 to 928MHz 1 Watt 30dBm 500kHz Cla
13. 6 10 1 1 Sub Menus The character appearing to the right of the menu item indicates that it has a sub menu Displaying Sub Menus To display a sub menu e Use the lt UP gt and lt DOWN gt arrow keys to position the cursor on the menu item with the sub menu you want to display Press lt F1 gt the NEXT menu function key Returning To The Previous Menu e Press lt F2 gt the PREV function key or e Press lt ESC gt 244 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 6 Tekterm Application Numeric Parameters 6 10 1 2 Numeric Parameters Numeric parameters are displayed in reverse video To increment or decrement a number Press the lt RIGHT gt or lt LEFT gt arrow keys or Type the desired number in the field Negative values are entered by typing a minus sign and then the number e Press lt ENTER gt Each numeric parameter has a preset range of numbers assigned to it for example a preset range of 1 through 10 If you attempt to enter a number which either exceeds 10 or falls below 1 the incorrect value will be rejected the original value for this parameter if any will be displayed 6 10 1 3 Y N Parameters Y N parameters can only be enabled Y or disabled N To enable or disable a Y N parameter Press the lt RIGHT gt or lt LEFT gt arrow key once or Type y to enable or n to disable the parameter Some Y N parameters have su
14. Console Port PR RS232 and PR Tether options allow you to enable disable and specify the accessories attached to these ports These are Disabled Serial Console Printer and Scan See To scroll through the options for each port e Press the lt RIGHT gt or lt LEFT gt arrow key These ports operate differently depending on the accessories selected e e e Disabled indicates that the serial port is not being used Serial standard serial port Console used to connect another PC to the 7535 7530 A communication program is required so that communication can proceed between the 7535 7530 and the PC Printer all TESS print operations are directed to the port All ANSI media copy operations to the primary port are directed to this port Scan See TESS and ANSI accepts input from the Scan See through the Tether or Console port 308 Psion Teklogix 7535 7530 Hand Held Computer User Manual 6 20 2 Port Parameter Settings Chapter 6 Tekterm Application Port Parameter Settings The parameters for the Tether Port Console Port PR RS232 and PR Tether are identical Range 04 Settings Character Set gt Baud 9600 Data Bits 8 Parity none Stop Bits 1 Flow Ctrl None Buffer 512 Retries 3 Input Tmo 2 Output Tmo 5 Shared N Test N see text see text for range of baud rates 6 8 none odd even mark space l I5 2 None Sof
15. Fujitsu Host Emulation If this parameter is set to Y data is sent in Fujitsu format Enabling Fujitsu Host causes the standard IBM formatting codes for start of field setting buffers etc to be replaced by the codes used by Fujitsu host computers Intl EBCDIC If this parameter is enabled set to Y the international EBCDIC character set is used swapping the positions of the and characters Nulls in Fields Setting this parameter to Y allows null characters e g hyphens or periods to fill in empty entry fields IP for SysReq When the system request key is pressed a Telnet Interrupt Process command is generated The Interrupt Process command is sent to the host in place of the standard mechanism used to send the system request key press to a host using Telnet Psion Teklogix 7535 7530 Hand Held Computer User Manual 303 Chapter 6 Tekterm Application Emulation BRK for Attn When the attention key is pressed a Telnet Break command is generated This command is sent to the host in place of the standard mechanism used to send the attention key press to a host using Telnet LU Name Enabled If enabled set to Y this parameter allows the 7535 7530 to negotiate a specific device name for itself LU Name The value assigned in this field is used when the LU Name Enabled parameter see above is set to Y The current te
16. The lt ENTER gt key normally enters data into a field and moves the cursor to the next field However some applications require that the lt ENTER gt key start a transmission from the 7535 7530 When enabled set to Y this parameter causes the lt ENTER gt key to be interpreted as lt FO gt which starts a transmission Enter On Arr When this parameter is enabled set to Y the arrow keys can be used to complete data entry into a field Video 06 Video Range Blink BLNK see text Bold ULIN see text Reverse REV see text Blink The value assigned to this parameter specifies the actual video attributes to be assigned to fields created with the Blink TESS attribute that is BLNK blink ULIN underline REV reverse or NONE normal Bold The value assigned to this parameter specifies the actual video attributes to be assigned to fields created with the Bold TESS attribute that is BLNK blink ULIN underline REV reverse or NONE normal Reverse The value assigned to the Reverse parameter specifies the actual video attributes to be assigned to fields created with the Reverse TESS attribute that is BLNK blink ULIN underline REV reverse or NONE normal All Fld Video Usually the video attributes apply only to the text that is in an entry field When thi
17. and so the area displayed on the Scan See will be 11 9 7 0 to 11 9 9 7 0 1 or 2 7 to 11 8 1 These computations assume that Wraparound described on page 315 is dis abled set to N and that Follow Cursor described on page 315 is enabled set to Y f Psion Teklogix 7535 7530 Hand Held Computer User Manual 313 Chapter 6 Tekterm Application Scan See Sub Menu Mapping The Viewport 012 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 0 0 l minal 3 4 7 5 Y x z 4 4 6 gt 7 Uo 2 oi 2 anchor 11 7 2 00 01234567809 9 o eo 10 ivot t minal pivo ursor offset Scan See Display Terminal Display superimposing the anchor on the pivot 0 12345 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 21 0 0 nchor 2 7 pivot 11 8 nN Note To enter negative values press the minus key and then type the number you want to use The lt LEFT gt arrow key can also be used to decrement the value assigned to the parameter Each time the lt LEFT gt arrow is pressed the number is decremented by one For example to enter a value of 5 start from
18. ee ee 252 6 16 System ParameterS o ee 254 6 16 1 Keyboard o e 255 6 16 2 AUGIO 0000 ad a ill 257 6 16 3 Power Mgmt Ctrl Panel o o o o o 258 6 16 4 User Permissions 20 000 eee ees 258 6 16 5 Windows Properties 2 e 259 6 16 6 Auto Start aia rd a eh bao els A 259 6 17 Scanner Control Panel 260 6 18 View Manager 2 ee 260 6 18 1 Split Screen ee 261 6 18 2 Custom Characters Unicode 264 6 19 Applications ici ci e m e ete a i ee ee 267 6 19 LAN ST Settings e cg ae Sane Sa ee o bea 268 6 19 22 TESS Settings o 20 cvs ada dd 285 6 20 Ports Tether And Console 000 308 6 20 1 Peripheral Port Options o o e 308 6 20 2 Port Parameter Settings o 309 6 20 3 Port Scan See Parameters o 312 6211 Network 105 a a la An Soc BR we Ree Be S 317 6 21 1 Network Ctrl Panel Settings o 317 6212802 1OW2 ete of a a ein e a heal Dad 318 Chapter 7 Peripheral Devices amp Accessories 7 1 External Bar Code Readers 2 00 004 323 7 1 1 PowerScan Standard LR and XLR Bar Code Scanners 323 7 1 2 Entering Data With The Bar Code Reader 323 TI Batteries sra e oak ids to a Sick ae kes ig EN aS ea ee ha 323 7 2 1 Lithium Ion Battery Safety Precautions 323 7 3 Important Charger S
19. lt ORANGE gt and lt ENTER gt keys for minimum of 6 seconds 32 Psion Teklogix 7535 7530 Hand Held Computer User Manual GETTING To Know YOUR 1535 7530 3 1 Features Of The 753S cc a a ww G 35 3 2 Features Of The 7530 e 36 3 3 The Batty rd A Gen ia A 37 33 1 Battery Safety all oe E A A as ee 37 3 3 2 Removing And Installing The Battery Pack 37 3 3 3 Battery Chargers o siine pne a A a o 38 3 4 Switching The Hand Held On And Off oaa 39 3 5 The Keyboard i lt ira in id ai a N 40 3 5 Modifrer Keys suet iru ss nied a wi oes hd wing 40 3 5 1 1 Activating Modifier Keys 0 4 4 41 3 5 1 2 Locking Modifier Keys o 41 E A LAA A E 41 3 5 3 Alphanumeric Keyboards 58 Key And 63 Key 42 3 5 4 Numeric Keyboards 36 Key And 37 Key 43 3 5 5 The Keypad Backlight 0 o 45 3 6 The Display 2c ee dd atte Bei gions Ge ea ae RA eae hoe ae 45 3 6 1 Adjusting The Display Backlight 45 3 6 2 Adjusting The Contrast 2 ee 45 3 6 3 Calibrating The Touchscreen 2 20005 46 3 7 7933 7530 Indicators sss seats ia 47 FEEDS u ee A A A di a ae ee 47 37 VA Charge LED ear a a 48 3 7 1 2 Radio Traffic LED o a 49 SAS Sa LED e ee ORS hv aie BAS Be 49 3 7 1 4 User Application LED 49 3 7 2 Onscreen Indicators ee 50 3 7 3 Audi
20. s intelligent charging system protects the battery from over charging by terminating the charge process when the battery is at maximum capacity NA Important To preserve battery integrity the charger will proceed with a charge only when the battery temperature falls between 5 C and 39 C 41 F to 102 F If the battery is too hot or cold the battery status LED flashes yellow and the charge is suspended 1 5 Gang Charger The gang charger is designed to charge up to six 7535 7530 Lithium Ion batteries at one time Your charger is shipped with the appropriate IEC mains power cord If the supplied power cord is incorrect for your country contact Psion Teklogix for assistance see Appendix A Support Services And Worldwide Offices E Note The gang charger is shipped with a user manual It is critical that this manual be reviewed for additional information and updates 326 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 7 Peripheral Devices amp Accessories Installation 1 5 1 Installation The gang charger can be wall mounted using the wall mount kit PN 1010039 or it can be operated on a flat surface Install the charger in an area that is free from excessive dirt dust and contaminants The ambient temperature must be in the range 5 C to 39 C 41 F to 102 F The charger will not charge batteries outside of this temperature range For maximum performance it is recommended that the charger be
21. ve finished recording your macro sequence press the key sequence lt CTRL gt lt ALT gt lt ENTER gt or choose the Stop Recording button A new screen displays the macro sequence you created The Save Macro button is highlighted e Press lt ENTER gt to save your macro E Note If you want to discard the macro you ve just created highlight the Discard Macro button and press lt ENTER gt Executing A Macro To execute a macro e Press the macro key to which you ve assigned the macro For example if you created a macro for macro key 1 press lt M1 gt to execute the macro 102 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 5 Configuration Unicode Mapping Deleting A Macro To delete a macro In the Macros tab highlight the macro number you want to delete e Choose the Delete Macro button 5 5 2 5 Unicode Mapping Inthe Keyboard Properties dialog box open the Unicode Mapping tab a U 0061 b U 0062 Y c U 0063 gt 6 la i OF Figure 5 12 Unicode Mapping The Unicode Mapping tab is used to map combinations of virtual key values and lt CTRL gt and lt SHIFT gt states to Unicode values This tab shows the configured Unicode character along with the Unicode value For example the sample screen above shows a U 0061 indicating that the character a is represented by the Unicode value 0061 and so on Keep in mind that Unicode configurations are r
22. 115 2kbps 128 0kbps or 256 0kbps Data Bits This parameter determines the number of bits for the data going through this port Possible values are 6 7 8 Parity This parameter determines the type of parity checking used on the data going through the port The options are none odd even mark and space Stop Bits This parameter specifies the number of stop bits 1 1 5 2 used for asynchronous communication Flow Control This parameter selects the type of flow control used in your hand held computer The 7535 7530 can perform Software or Hardware handshaking or you can choose Both to enable both of these options The function of each mode is as follows Enable Used to input and output data Supports XON XOFF or no handshaking 310 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 6 Tekterm Application Port Parameter Settings Print Used to output data only All input characters except XON and XOFF are ignored Supports XON XOFF or no handshaking Output Used to output data only All input characters are ignored Supports no handshaking AL Note To enable the input and or output serial in and or serial out must be enabled in the TESS menu Buffer The value assigned to this parameter determines the size of the serial buffer used by the application for both input and output The buffer controls the amount of data the application can send to or receive from a serial device
23. 162 5 10 4 Decoded Intermec ISCP o 178 A E A E TE 181 5 10 6 Decoded External o a 188 5 1077 Options Tab see alte ang a o Mee 191 5 10 8 Translations A AS 193 SNMP Simple Network Management Protocol Setup 194 Ssh Contact Tabs cuca Sage eae chs ce 4 Sea Bee a 195 5 11 2 Communities Tab 196 5 11 3 Trap Destination Tab o ee ee 199 5 11 4Permitted Hosts Tab 201 Wireless WAIN cocotero ia ad ata Boos 202 5 12 1 Taskbar Icons 202 5 12 2 Establishing A Connection o ooo 203 5 12 3 Disconnecting From A Network aoaaa aaa 205 5 12 4 Advanced Information 206 S129 TOOLS MI e E A A a a a la 208 iv Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 6 Tekterm Application 6 1 The Tekterm Application 204 6 2 Additional Keyboard Functions o o 6 2 1 Function Keys And Softkeys 6 2 2 Macro KeyS 00002 eee ee 6 3 Changing The Screen Font Size 200004 6 4 Panning The Screen Contents 0000004 6 4 1 Using The Task Manager To Switch Between Applications 6 5 The Tekterm Status Area o o e 000 6 6 TESS Emulation ess dla Ar naa o o 6 6 1 Configuration ee 6 6 2 Working With Multiple Sessions 6 6 3 The Field Types ioc ates o ee we ee a wt A 6 6
24. 176 Psion Teklogix 7535 7530 Hand Held Computer User Manual Chapter 5 Configuration 2D RSS Code Reduced Space Symbology Field Size Chars Refer to page 154 for details 5 10 3 17 2D RSS Code Reduced Space Symbology Enable Setting this parameter to on enables 2D RSS Code scanning capability Enable RSS 14 RSS 14 code can be either purely linear or split in half with one half stacked on top of the other half Stacking the code reduces the bar code length and providing the nominal height of the code is maintained it can be omni directionally scanned Enable RSS Limited RSS Limited is restricted in that it can only encode 14 digit GTINs global trade item number that begin with either a 0 or a 1 It is not stackable and is not designed to be read omni directionally Enable RSS Expanded RSS Expanded uses the same application identifiers as UCC EAN 128 codes but they can be split into sections and stacked several rows high reducing the length of the symbol while increasing the capacity of data that can be stored RSS Expanded code can be omni directionally scanned Field Size Chars Refer to page 154 for details 5 10 3 18 Composite Important To successfully read this type of bar code the two types of symbologies included in a composite bar code must be enabled In addition Center Bar Code Only must be disabled A composite symbol includes multi row 2D components making it compatible
25. 6 18 2 Custom Characters Unicode M 0 o 264 6 18 2 1 Creating A Unicode Character 264 6 18 2 2 Displaying The Unicode Pop up Window 265 6 19 Applications i 2 aco ase ta dee e ia OLR ee BE we 267 6 1 9 1 cANST SSUMES lt onesie du Po a o 268 6 19 1 1 Host Conn o o e o 269 6 1 981 2 Serene ia a oe ete ed a eee 273 6 19 1 3 Xmit Modes 00000088 276 6 19 1 4 Kbd Modes ci a ote oy de a daa dd dod Bu enw 280 6 19 1 5 Edit ModesS o o o e a ae a 283 6 19 16 AOS 284 6 19 1 7 Host Char Sel s iaa we hes bee ee hh e 284 6 19 1 8 Anchor View o e 285 6 19 2 TESS Settings 0 44 one a de 285 6 19 2 1 HostConn 2 e i a a ee es 286 0 19 22 SCT edi and tt ae tee pale oh Wee wend act 287 6 19 2 3 Characters sen u enre naaa ee be ee Gg 289 6 1924 TOS AS BS ES E 291 6 19 2 5 Features se e o a ee a 292 6 19 26 Scanner sso E ai Ghee ke A ae A 296 61927 AA ko Se inal yh vn BAS 4 9S oh ha ae 297 6 19 2 8 Anchor View 2 0 020000 ee eee 300 6 19 2 9 Emulation o gee doina eraa a ee 300 6 20 Ports Tether And Console 308 6 20 1 Peripheral Port Options 2 20004 308 6 20 2 Port Parameter Settings 002 0002 eee 309 6 20 3 Port Scan See Parameters o e 312 6 20 3 1 Scan See Sub Menu Mapping The Viewport 312 6 20 3 2 Scan See Keyboa
26. 6 2 Additional Keyboard Functions 002 0000 eee 221 6 2 1 Function Keys And Softkeys 020 0000 221 6 2 1 1 7535 Function Keys 2 20 0 ee ees 221 6 2 1 2 7530 Function Keys 2 0 20 00 eee ees 222 6 2 1 3 Softkey Function KeyS o o 223 6 22 Macro KEYS otitis A A Sn hee 224 6 3 Changing The Screen Font Size 2 ee 225 6 4 Panning The Screen Contents 2 0 0 2 ee ee 225 6 4 1 Using The Task Manager To Switch Between Applications 226 6 5 The Tekterm Status Area aooaa es 227 6 6 TESS Emulation 2 0 ee 227 6 6 1 Configuration aoaaa 228 6 6 2 Working With Multiple Sessions 04 228 6 6 3 The Field Types mo a8 der eae s dea Big eva hawt 228 6 6 4 IBM 5250 Emulation KeyS o 229 0 60 Dita ENEY oc a di eh ea a 229 6 6 5 1 TESS Edit Modes And Cursor Movement 230 6 6 5 2 lt DEL gt Key Behaviour In TESS 231 6 6 5 3 lt BKSP gt Key Behaviour In TESS 232 6 6 6 TESS Status Message ee 233 6 6 7 Lock Messages ip a dad oe a ee a ae 234 6 6 8 Control Commands aaa 234 6 6 9 Resetting A TESS Session o oo pe eee 234 6 6 10 The Local Menu aoaaa aaa 2 000000 200 235 6 6 11 Selecting Another Host Computer 235 6 6 12 Queuing Mode e 236 6 1 ANST Emulation ica ora a AR 236 6 7 1 Configuration posee nana
27. 7530 224 maintenance 7535 63 Manual Radio Address Cellular Radio Address 144 Manual Switch Table 42 mapping keyboard Scan See 3 6 mapping viewport 3 2 match fields 228 MATM 279 Max Gain Imager 183 Max Illumination Imager 1 83 Max Integration Imager 53 Media Copy ANSD 278 memory resetting 249 menu local 235 Menu mode taskbar switching between apps 226 menus working with 244 message mask msk 242 messages enabling disabling next message 293 LOCK B 234 288 LOCK H 234 288 NEXT B 235 236 NEXT H 235 236 RESET Press Enter Scan Indicator 92 scanner warning message 192 Scan Result 792 TESS status message 233 messages retransmitting 802 IQv1 xr See xr retransmissions 242 messages received rm 242 messages transmitted xm 242 milestone 293 Mixed AIAG 297 mnemonics ANSI 283 mode serial O 294 Model 7000 Brightness 3 5 modifier keys 40 locking 41 One Shot Mode 00 unlocking 4 Modulation Baud Rate 48 Mod 10 Check 754 162 Mod 10 Check Discrete 2 of 5 symbology 161 Mod 10 Check 12 of 5 symbology 160 Mod 43 Check 754 moving the display 261 288 MSI Plessey 161 174 181 msk message mask 242 multiple ANSI sessions 267 applications 267 hosts 235 TESS sessions 267 Multiple Area Transfer Mode MATM 279 227 Psion Teklogix 7535 7530 Hand Held Computer User Manual Index Xi Index N Name 197 name servers assigning 29 Narrow Band radio 137
28. ANSI 269 Host Conn TESS 286 menu Applications 267 Scanner parameters TESS 296 Screen parameters ANSI 273 Screen parameters TESS 287 TESS Settings 285 300 Type and Title 267 approvals 7530 including scanner 351 7535 including scanner 348 ar acknowledged remote number 242 Arrow Key Remap ANSI Telnet Settings 272 arrow keys 237 completing a data field 229 298 cycling through special characters 246 Enh Mode using 299 moving the cursor 4 Arrow mode 280 Arrows 316 ASCII