Home

SCHURTER DC12 POWER ENTRY MODULES WITH LINE FILTER handbook

image

Contents

1. lt INDEX BY TYPES amp SCHURTER C14 70 C Description Panel mount POWER ENTRY MODULES WITH LINE FILTER Snap in or screw on mounting from front side 3 Functions Connector Protection class Line switch 1 or 2 pole Line filter in standard and medical version Quick connect terminals 6 3 x 0 8 mm Alternative version without line filter gt DC11 Substitute for type 1 KFB2 DC12 Actual information about approvals can be found on http www schurter com approvals Standard or Medical Filter Characteristics Compact design with optimal shielding All single elements are already wired Line switch non illuminated Universal line filter for standard applications Ideal for application with high transient loads Qualified for use in equipment according IEC EN 60950 Other versions on request solder terminals other rocker marking line switch illuminated Capacitance 1 medical version M80 for protection class II Technical data Ratings IEC 1 10 A Ta 40 C 250 VAC 50 Hz Appliance inlet outlet C14 acc to IEC EN 60320 1 Ratings UL CSA 1 10A Ta 40 C 125 VAC 60 Hz UL 498 CSA C22 2 no 42 for cold Leakage current standard lt 0 5 mA 250 V 60 Hz medical lt 5 pA 250 V 60 Hz Dielectric strength gt 1 7 kVDC between L N gt 2 7 kVDC between L N PE Test voltage 2 sec condition pin temperature
2. 101 10 Medical Version M5 Snap in 2 pole DC12 1202 003 1 Medical Version M5 Screw on 1 pole DC12 2202 003 2 Medical Version M5 Screw on 1 pole DC12 3202 003 4 Medical Version M5 Screw on 1 pole DC12 4202 003 6 Medical Version M5 Screw on 1 pole DC12 5202 003 10 Medical Version M5 Screw on 1 pole DC12 1202 001 1 Medical Version M5 Screw on 2 pole DC12 2202 001 2 Medical Version M5 Screw on 2 pole DC12 3202 001 4 Medical Version M5 Screw on 2 pole DC12 4202 001 6 Medical Version M5 Screw on 2 pole DC12 5202 001 10 Medical Version M5 Screw on 2 pole Packaging unit 10 Pcs Accessories ACCESSORIES
3. 70 C 10 A Protection class Allowable operation temp 25 C to 85 C Climatic category Degree of protection 25 085 21 IEC 60068 1 from front side IP40 acc to IEC 60529 Protection class Suitable for appliances with protection class acc to IEC 61140 Terminals Quick connect terminals 6 3 x 0 8 mm Panel thickness s Screw on max 8 mm Mounting screw torque max 0 5 Nm 1 mm to mm aterials Housing Thermoplastic black UL 94V 0 Line switch Rocker switch 1 or 2 pole non illumi nated acc to IEC 61058 1 Technical details GENERAL PRO DUCT INFORMATION Line filter Standard and medical version IEC 60939 IEC 60601 1 UL 1283 UL 544 EN 133 200 CSA C22 2 no 8 Technical details GENERAL PRO DUCT INFORMATION INDEX BY TYPES amp SCHURTER Dimensions Screw on mounting Snap in mounting Technical data of filter components Rated current A 1 Standard Version Standard Version Standard Version Standard Version Standard Version Medical Version M5 Medical Version M5 Medical Version M5 Medical Version M5 Medical Version M5 POWER ENTRY MODULES WITH LINE FILTER 32 70 Inductances Capacitance Capacitance L mH 2x10 2x4 2x1 5 2x0 8 2x0 3 2x10 2x4 2x15 2x0 8 2x0 3 CX nF 100 100 100 100 100 100 100 100 100 100 CY
4. ine switch DC12 1102 103 1 Standard Version Snap in 1 pole DC12 2102 103 2 Standard Version Snap in 1 pole DC12 3102 103 4 Standard Version Snap in 1 pole DC12 4102 103 6 Standard Version Snap in 1 pole DC12 5102 103 10 Standard Version Snap in 1 pole DC12 1102 101 1 Standard Version Snap in 2 pole DC12 2102 101 2 Standard Version Snap in 2 pole DC12 3102 101 4 Standard Version Snap in 2 pole DC12 4102 101 6 Standard Version Snap in 2 pole DC12 5102 101 10 Standard Version Snap in 2 pole DC12 1102 003 1 Standard Version Screw on 1 pole DC12 2102 003 2 Standard Version Screw on 1 pole DC12 3102 003 4 Standard Version Screw on 1 pole DC12 4102 003 6 Standard Version Screw on 1 pole DC12 5102 003 10 Standard Version Screw on 1 pole DC12 1102 001 1 Standard Version Screw on 2 pole DC12 2102 001 2 Standard Version Screw on 2 pole DC12 3102 001 4 Standard Version Screw on 2 pole DC12 4102 001 6 Standard Version Screw on 2 pole DC12 5102 001 10 Standard Version Screw on 2 pole DC12 1202 103 1 Medical Version M5 Snap in 1 pole DC12 2202 103 2 Medical Version M5 Snap in 1 pole DC12 3202 103 4 Medical Version M5 Snap in 1 pole DC12 4202 103 6 Medical Version M5 Snap in 1 pole DC12 5202 103 10 Medical Version M5 Snap in 1 pole DC12 1202 101 1 Medical Version M5 Snap in 2 pole DC12 2202 101 2 Medical Version M5 Snap in 2 pole DC12 3202 101 4 Medical Version M5 Snap in 2 pole DC12 4202 101 6 Medical Version M5 Snap in 2 pole DC12 5202
5. nF 2 2 2 2 2 2 2 2 2 2 EH DC12 INDEX BY TYPES SCHURTER POWER ENTRY MODULES WITH LINE FILTER DC12 Diagrams Standard filter 1 pole Standard filter 2 pole Medical filter 1 pole M5 Medical filter 2 pole M5 1 Line 1 Line 1 Line 1 Line 2 Load 2 Load 2 Load 2 Load Attenuation loss differential mode _ mode Standard version 1A 2A 4A 6A dB dB GG IR 2 IS S 40 H IL TIR Le s ll oot of 10 HD 0 01 0 1 10 100 400 MHz 10 t a i au a H f i a ah x T Y o a HH 11 0 01 Di 1 10 100 400 MHz Medical version 1A 2A 4A 6A P HUIR Ill HHI Hi l Dt 008 Lu T BEZ 4 25 Sege III 001 oi 1 10 100 400MHe 2001 ZC 1 HS 100 400 MHz INDEX BY TYPES 6 SCHURTER POWER ENTRY MODULES WITH LINE FILTER DC12 Variants Order Number Rated current Filter Type Panel mounting L