1. includes all of the above E Precision Cooling H site Monitoring and Services 1 Specifications subject to change without notice 2 All dimensions in inches mm tolerance is 0 02 0 5mm 3 Mounting holes M1 and M2 should be grounded for EMI purposes EmersonNetworkPower com 4 Mounting hole M1 is safety ground connection 5 Specifications are for convection rating at factory settings at 115 VAC input 25 C unless otherwise stated Emerson Network Power and the Emerson 6 Warranty 2 year Network Power logo are trademarks and 7 Weight 0 5lbs 0 23kg service marks of Emerson Electric Co 2007 Emerson Electric Co
2. 4A 5 120mV 5V OA 0 5A 0 7A 1A 5 50mV LPT45 T 5V 0 4A 4A 5A 7A 2 50mV 15V 0 2A 2A 2 5A 3A 5 150mV 15V OA 0 5A 0 7A 1A 5 150mV LPT46 T 5V 0 44 4A 5A 6A 2 50mV 24V 0 1A 1 0A 1 5A 2A 7 240mV 12V OA 0 5A 0 7A 1A 5 120mV LPT47 T 5V 0 44 4A 5A 6A 2 50mV 24V 0 2A 1 0A 1 5A 2A 7 240mV 12V OA 0 5A 0 7A 1A 5 120mV Peak current lasting lt 30 seconds with a maximum 10 duty cycle At 25 C including initial tolerance line voltage load currents and output voltages adjusted to factory settings Minimum Loads are required 1 2 3 Peak to peak with 20 MHz bandwidth and 10 pF in parallel with a 0 1 pF capacitor at rated line voltage and load ranges 4 5 T indicates Terminal Block option for input and output instead of Molex type 5 3 Output Power 5W ow Watts 20W 1 ow ow Power Derating Curve 27 5W Natural Convection Cooling 20W T T T T T T orc 10 C 20 C 30 C 40 C 50 C 60 C 70 C TA Ambient Temperature C Embedded Power for Business Critical Continuity Rev 02 05 07 LPT40 Series Astec 3 of 3 5810 Van Allen Way Carlsbad CA 92008 USA Telephone 1 760 930 4600 Facsimile 1760 930 0698 Remote Sense Waterfront Business Park Connector Merry Hill Dudley Voltage West Midlands DY5 1LX Adj Pot United Kingdom Telephone 44 0 1384 842 211 Facsimile 44 0 1384 843 355 13 15 Shing Wan Road Tai Wai
3. O Embedded Power for Business Critical Continuity Rev 02 05 07 LPT40 Series 1 of 3 Total Power 40 55 Watts Input Voltage 85 264 VAC 120 300VDC of Outputs Triple Special Features Universal input 3 x 5 footprint Less than 1U high Remote sense on main output Terminal Block option T Built in EMI filter Low output ripple Adjustable main output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available Safety UL UL60950 E132002 CSA CSA 22 2 234 Level 3 LR53982C NEMKO EN 60950 EMKO TUE CB CE P95100411 74 sec 203 Certificate and report WN WU Wess Wl Mark LVD Input Input range Frequency Inrush current Input current Efficiency EMI Safety ground leakage current Output Maximum Power Cross regulation Adjustment range Hold up time Overload protection Overvoltage protection Remote sense OL ASTEC 85 264 VAC 120 300 VDC 47 440 Hz lt 18A peak 115VAC 2002 95 EC lt 36A peak 230VAC cold start 25 C 1A max RMS 115VAC 70 typical at full load 60 for LPT41 FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted lt 0 5 mA 50 60 Hz 264 VAC input AOW for convection LPT41 25W 55W with 30CFW forced air LPT41 41W 2 on output 1 5 on outputs 2 3 5 10 minimum 20ms 40W load 115 VAC nominal line Sho
4. Shatin N T Hong Kong Telephone 852 2699 2868 Facsimile 852 2699 1770 0 15 4 For global contact visit DIA 4 places www astecpower com technicalsupport astec com While every precaution has been taken to ensure accuracy and completeness in this literature Emerson Network Power assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions Connector LPT41 LPT42 LPT43 LPT44 LPT45 LPT46 LPT47 K201 1 Sense Sense Sense Sense Sense Sense Sense SK1 1 Line Line Line Line Line Line Line SK1 3 Neutral Neutral Neutral Neutral Neutral Neutral Neutral SK2 1 5V 12V 12V 12V 15V 424V 24 Emerson Network Power SK22 sV V Sy 5V 5V 5V 5V The global leader in enabling SI SMO N SN ee business critical continuity SK2 4 Common Common Common Common Common Common Common SK2 5 Common Common Common Common Common Common Common SoG N aN Iw VV 15V 12V 12V AC Power Ss S E Connectivity E Dc Power E Embedded Power K201 2 Sense Sense Sense Sense Sense Sense Sense AC Input Molex 09 50 8031 USA Not required for T option 09 91 0300 UK PINS 08 52 0113 E Inbound Power DC Outputs Molex 09 50 8061 USA Not required for T option Integ rated Cabinet Solutions 09 91 0600 UK PINS 08 52 0113 Outside Plant Remote Sense Molex 22 01 2025 Astec Connecto PINS 08 52 0123 r Kit 70 841 006
5. rt circuit protection on all outputs Case overload protected 110 to 145 above peak rating 5 7 to 6 7 VDC on the main output LPT41 3 6 to 4 6VDC Compensates for 0 5 V lead drop min Will operate without remote sense connected Reverse connection protected S EMERSON Embedded Power for Business Critical Continuity Rev 02 05 07 im R LPT40 Series Environmental Specifications 2of3 Operating temperature 0 to 50 C ambient derate each output at 2 5 per degree from 50 to 70 C 20 C start up Electromagnetic Designed to meet IEC 801 2 3 4 5 6 Level 3 susceptibility Humidity Operating non condensing 5 to 95 Vibration Three orthogonal axes sweep at 1 oct min 5 min dwell at four major resonances 0 75G peak 5 Hz to 500 Hz operational Storage temperature 40 to 85 C Temperature coefficient 04 per C MTBF demonstrated gt 550 000 hours at full load and 25 C ambient conditions Model Output Minimum Maximum Load Maximum Load P with Convnection with 30CFM PeakLoad Regulation Ripple P P PARD Number Voltage Load z i cooling Forced Air LPT41 T 3 3V 0 5A 4A 7A 7A 2 50mV 5V OA 1 5A 2 0A 2 5A 2 50mV 12V OA 0 5A 0 7A 0 7A 5 120mV LPT42 T 5V 0 4A 4A 5A 7A 2 50mV 12V 0 2A 2A 2 5A 4A 5 120mV 12V OA 0 5A 0 7A 1A 5 120mV LPT43 T 5V 0 5A 6A 8A 9A 2 50mV 12V OA 0 5A 0 7A 1A 5 120mV 12V OA 0 5A 0 7A 1A 5 120mV LPT44 T 5V 0 44 4A 5A 7A 2 50mV 12V 0 2A 2A 2 5A