1. 80 R H up to 31 C decreasing linearly to 50 R H at 40 C Altitude Operating below 2000 m Storage temperature 20 C 60 C lt 80 R H with battery removed Temperature coefficient Nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Sensing Average sensing Overload protection 450 V de and V ac rms Low battery Below approx 2 4 V Power supply 3 V standard button battery x 1 IEC CR2032 ANSI NEDA 5004LC Power consumption typical 2mA Automatic Power Off APO timing Idle for 3 minutes APO consumption typical 2 2 pA Dimension Weight L 113 mm x W 53 mm x H 10 2 mm 4 4 x 2 1 x 0 4 in Approx 78 gm 3 oz Special features AutoTect Automatic V amp Q selection and VolTect Electric Field Detection Agency approvals CE cULus 49221 0A pUe 32L0yNY YUM Ja 9WINW 12481A edWI0D Safety Meets IEC61010 1 UL61010B 1 CAN CSA C22 2 No 1010 1 92 CAT II 450 V and CAT III 300 V Pollution Degree 2 Class 2 E M C Meets EN61326 Accessories Included Battery installed User s manual and H PM silicone holster Optional VC3 zippered carrying case
2. PM53A AutoTect feature dreds the meter to know if it is measuring ac volts dc volts or resistance with no user interface required The AutoTect feature has lower input impedance which zeros out ghost voltages Measures capacitance frequency continuity with beeper plus includes VolTect a built in non contact voltage detector Complete user protection with full safety ratings of CAT III 300 V CAT II 450 V and UL and CSA listing Large oversize digital display Protective silicon holster included attached test leads battery and manual One year no hassle The compact commercial DMM with AutoTect and VolTect This meter is the essential shirt pocket size meter Only 3 8 thick and less than 3 oz in weight this meter offers full functionality with ac and dc voltage to 450 V resist ance to 6 Megohm capacitance to 100 uF frequency to 30 kHz and continuity w beeper It also offers VolTect a built in non contact voltage detector for ac voltages Another key feature is AutoTect which automatically selects ac voltage dc voltage or resistance measurement based on the test point to which the leads are connected Fully autoranging this meter offers seven different meas urement functions plus features that are usually found in much more expensive and larger meters The digital display is oversized with large digits and unit icons in the display In spite of its size this meter is fully s
3. afety rated to CAT III 300 V CAT II 450 V and is UL listed Includes a silicone protective holster attached test leads battery and manual pMS3A Specifications Accuracy at 23 C 5 C lt 75 R H RF field 3 V m Specified accuracy 45 d capacitance not specified DC Voltage Range Accuracy 6 000 V 0 5 3 dgt 60 00 V 1 0 5 dgt 450 0 V 1 2 5 dgt NMRR gt 30 dB 50 Hz 60 Hz CMRR gt 100 dB DC 50 Hz 60 Hz Rs 1 kQ Input impedance V de AutoTect threshold AutoTect Lo Z V de 160 KQ 160 pF nominal gt 1 2 V dcor lt 0 6 V dc nominal AC Voltage Range Accuracy 50 Hz 60 Hz 6 000 V 60 00 V 450 0 V 1 5 5 dgt CMRR gt 60 dB dc to 60 Hz Rs 1 kQ Input impedance AutoTect Lo Z V ac 160 kQ 160 pF nominal ACV AutoTect threshold gt 1 5 V ac 50 Hz 60 Hz nominal Capacitance Range Accuracy 100 0 nF 1000 nF 10 0 pF z i 100 0 pF 3 5 6 dgt Accuracy below 50 nF is not specified Accuracies with film capacitor or better Top range Updates gt 1 minute on large values Specified with battery voltage above 2 8 V half full battery Accuracy decreases gradually to 12 at low battery warning voltage of approx 2 4 V Resistance Range Accuracy 6 000 kQ 1 2 6 dgt 60 00 kQ 600 0 kQ 1 0 4 dgt 6 000 MQ 2 0 4 det Open circuit voltage 0 4 V dc t
4. ypical warranty J AutoTect is for 6 000 kQ 6 000 MQ ranges ad 40 dgt to specified accuracy while reading is below 20 of range J22L OA PUL 3LOyNY YPM JUN 12481A Pedwioy PM53A Amprobe Test Tools website www Amprobe com email info amprobe com 6920 Seaway Blvd Everett WA 98203 tel 877 AMPROBE Amprobe Test Tools Europe P O Box 1186 5602 BD Eindhoven The Netherlands 2006 Amprobe Test Tools All rights reserved Printed in U S A 12 2006 2277176 D US N RevC The compact commercial DMM with AutoTect and VolTect AAMPROBE PM53A Specifications cont Frequency Range Accuracy Specified at 100 Hz 1 kHz 10 kHz 0 5 4 dgt lt 20 V Sine rms Sensitivity Sine rms Hz in Auto VQ position gt 3 V VolTect Typical voltage Bar graph indication 15 V to 55 V 30 V to 85 V 55 V to 145 V 85 V to 190 V above 120 V Indication Bar graph segments amp audible beep tones proportional to field strength Detection frequency 50 60 Hz Detection antenna Top left corner of the meter Audible Continuity Tester Open circuit voltage 0 4 V dc typical Audible threshold 175 Q 125 Q General Specifications Display and update rate 3 5 6 digits 6000 counts Updates 5 per second nominal Operating temperature 0 C 40 C Relative humidity Max

Download Pdf Manuals

image

Related Search

AMPROBE PM53A handbook

Related Contents

          HANNA instruments HI 38058 Manual  Agilent Quality assurance of RNA derived from laser microdissected tissue samples obtained by the PALM MicroBeam system using the RNA 6000 Pico LabChip kit Manual  MAXIM INTEGRATED DS1647/DS1647P Manual      

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.