Home

Panasonic WJ-MP204 Data Multiplex Unit Operating Instruction Manual

image

Contents

1. 24 ALARM REMOTE N02 ALM OUT DUNT MM OUT ALM IN 9876 54321 dinm GND GND oyog Pin For Alarm For Remote Input Output Input Output 1 Alarm Output 2 Alarm Recover Input 3 Alarm Reset Output 4 Spot SW Input 5 Spot SW Output 6 1CH Alarm Input 1 Alarm Output 1 Change to Channel 1 Channel 1 Tally Output Camera Site Alarm picture 7 2CH Alarm Input 2 Alarm Output 2 Change to Channel 2 Channel 2 Tally Output Camera Site Alarm picture 8 3CH Alarm Input 3 Alarm Output 3 Change to Channel 3 Channel 3 Tally Output Camera Site Alarm picture 9 4CH Alarm Input 4 Alarm Output 4 Change to Channel 4 Channel 4 Tally Output Camera Site Alarm picture Notes The initial setting of alarm recovery signal is 0 5 volt In case of using Open Collector O C signal as alarm recovery signal set the SW704 to O C E Connector Selection for Setup Menu Output Under the default condition the setup menu will be output to the devices connected to the SPOT OUT connector and CAM ERA OUT connector 1 to 4 When Switch 1 of SW702 in the WJ MP204 is set to ON the setup menu will be output only to the devices connected to the SPOT OUT connector Do not change the positions of Switches 2 to 4 of SW702 Note Do not set the Switch 2 3 and 4 of SW702 20 I wes g amp E Or
2. J f J gt B RS485 Terminal Control data is transmitted and received to and from the Matrix Switcher WJ SX350 Use a data grade cable dou ble shield twisted pair cable suited to the RS485 Cable length may be extended up to 1 200 m 4 000 ft TB TA RB RA GND O Internal Diagram TB TA RB RA Fixed Only displays Displays the 4 w 3 the Setup Setup menu to 2 menu to CAMERA OUT SPOT OUT 1 4 and m 1 SPOT OUT ON OFF O Connection Connect one as shown below Set the Dip switch SW6 to 2 LINE half duplex or 4 LINE full duplex 4 Line Full duplex l i lu MODE UNIT SYSTEM UNIT Full duplex Termination ON at the end position Camera communication mode 2 Line Half duplex Termination ON at the end position Camera communication mode 26 E Connection to WV CU360 O Basic Connection Connect the DATA port on the Data Multiplex Unit to one of the DATA port on the System Controller with the RS 485 cable Data Multiplex Unit System Controller WJ MP204 WV CU360 RS 485 Cable Loop Through Connection 1 Plug the branch cable optional accessory into the DATA port on
3. ier tec lta dette A tta creta deed 9 B Setting Communication Mode eager vip reete RU dete RU d e E LRL e ER ie aerial 9 B Setting the Communication Mode via RS 485 or Data Port sse enne nennen terrens nnne nes 9 B Setting the VS or VD Signal Output acciona ada RnB eng eec don 9 SETTING ADDRESSES 4 22 02 ecd ten ue ete e educ tance b tete dese testo tad e fe et 10 i Panasonic Security Data Mode viii a 10 E Camera Communication Mode 2 a A dpe ce Ree cie ee 10 SETUP MENU e e RR e RE ep d pc dp e e ettet e e b e e 11 Mi Setup Men EM 11 E Displaying the Setup Menu for Panasonic Security Data Mode sess 12 il Communication Setup of Panasonic Security Data Mode sssssssssssseeeeeeeenenn enne nennen nennen nnne ns 12 B System Setup for Panasonic Security Data Mode ssssssssssssseseeee eene nennen nennen nennen nennen renes nene 13 E Displaying the Setup Menu of Camera Communication Mode ceccceeseeeceeeeeeeeeceereceaeeeaeeceeeesaaeeeeeeeneeesaeseeeeesiteseaeenaes 16 E Communication Setup for Camera Communication Mode esses nennen nennen nennen ns 16 Bi System Setup for Camera Communication Mode sssssseeeeneeeeenneeeenen neret ennt EnEn nnne rra 18 INSTALLATION iiaia e e Pepe tein e t beet e Ro e e e e es 20 I MOUNTING inthe Back x t dai 20 SYSTEM CONNECTION ii enc ER ee ee oL tet Ee cer UTR E RUD e eer ee nen O
4. ALARM DATA 1s Display the SYSTEM menu Move the cursor to ALARM MODE by pressing button 1 V or button 2 A press the SUSPEND SET button then select MONITOR SPOT ON or OFF by pressing button 3 or button 4 The initial factory setting is ON ON The screen of the corresponding channel appears when the alarm is activated If MONITOR SPOT ON with the mark 3 is selected the screen appears as shown below MONITOR SPOT ALARM CAM NO PRE 1 1CH 2 2CH 3 3CH 4 4CH Enter each camera number and a preset position for each alarm number If the Data Multiplex Unit is con nected to a combination camera enter a preset posi tion for the PRE parameter OFF The screen continues to display the pictures in the mode selected previously when the alarm is activated For further information on preset positions refer to the Operating Instructions for the combination camera Alarm Display Setting Display the SYSTEM menu Move the cursor to ALARM DISPLAY by pressing button 1 V or button 2 A then select ALARM DISPLAY ON or OFF by pressing button 3 or button 4 so that ALARM appears on the screen or not The initial factory setting is ON Note The figure shown in the place of after the word ALARM is a channel number Site Alarm Setting Display the SYSTEM menu Move the cursor to SITE ALARM by pressing button 1 Y or button 2 A then select SITE ALARM
5. Dimensions and weight are approximate Specifications are subject to change without notice STANDARD ACCESSORY Switch Protector cota 1 pc ALL RESET The Data Multiplex Unit WJ MP204 can be reset to the default settings as follows 1 Press the power switch to reset it to the OFF position 2 Press the power switch down to the ON position while pressing the camera selection buttons 2 3 and 4 3 Continue to press the camera selection button approximately 3 seconds after press the power switch down to the ON 4 When all indicators light up resetting is completed OY OA O O 1 2 4 30 APPENDIX E Operation of Data Multiplex Unit WJ MP204 versus Operation of System Controller WV CU360 The functions that can be controlled from both the WJ MP204 and WV CU360 in the way of their operation are summarized in the table below Function Camera Selection WJ MP204 Press Ov Oa O O 1 2 4 3 WV CUS60 Enter camera numbers by pressing numeric buttons CAM And Press SET Alarm Reset Press ALARM Oneser Press ALM RESET ALM RECALL Alarm Suspend Alarm Suspend Reset Press ALARM OsuspEno SET Press ALARM OSUSPEND SET Press AM SUSPEND e Press ine SUSPEND O Matsushita Electric Industrial Co Ltd Central P O Box 288 Osaka 530 91 Japan 2000 O Matsushita Communication Industrial Co Ltd All rights reserv
6. down pressing button 1 V or button 2 A 5 Press the SUSPEND SET button The COMMUNICA TION menu or the SYSTEM menu appears on the moni tor as shown below COMMUNICATION CAM ADDRESS 3 BAUD RATE 19200 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF DELAY TIME OFF XON XOFF NOT USE SYSTEM ALARM MODE ON Y COMP VD2 DATA Y VS VD INPUT VD DAISY MODE ON TERMINAL ALARM The following buttons are used with the Setup menu 1 W To move the cursor down 2 A To move the cursor up 3 To select a mode or parameter 4 To select a mode or parameter SUSPEND SET To enter the selections and display the submenu for the item indicated by the mark Y SETUP ESC To return to the previous menu 16 Notes To not display the Setup menu for camera output pic tures shift the internal switch See page 25 To finalize the settings press the SETUP ESC button for 2 seconds or more while the Setup menu is dis played To use the System Controller WV CU360 for operation refer to its Operating Instructions E Communication Setup for Camera Communication Mode 1 Display the Setup menu 2 Move the cursor to COMMUNICATION by pressing button 1 V or button 2 Then press the SUS PEND SET button In case of Camera Communication mode the COMMUNICATION menu appears as shown below COMMUNICATION CAM ADDRESS y BAUD RATE 19200 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WA
7. mode used See page 11 for details DIP SWITCH SETTING Before connecting the Data Multiplex Unit check how the DIP switches are set on the rear panel in cases where the System setup must be changed E Setting Communication Mode O Panasonic Security Data Mode Check that Dip Switches SW3 and SW4 are up ilii SW3 SW4 6 Camera Communication Mode Check that Dip Switch SW3 is down and Dip Switch T PET SW3 SW4 3 E Setting the Communication Mode via RS485 or Data Port O Termination Check that Dip Switch SW5 is down ON Note In case of using two Data Multiplex Units or more set Dip Switch SW5 on only one point at the end position of the unit to the down position OFF SW5 O Data Line Selection Mode Set DIP Switch SW6 to the 4 LINE or 2 LINE position according to the desired data line selection mode 4 LINE Full Duplex 2 LINE Half Duplex The initial factory setting is 4 LINE 4 LINE FAO 2 LINE SW6 Note Set SW6 to 4 LINE for communication in Panasonic Security Data mode E Setting VS or VD Signal Output O Supplying Video Drive Signal in Internal Sync Mode Check that Dip Switch SW1 is down VD THROUGH Kiinni Synchronized vertical drive signal is supplied in case of signal input to VS VD IN connector O Supplying Synchronized Signal Input to VS VD IN Connector Check th
8. the Data Multiplex Unit WJ MP204 2 Plug the branch cable into the DATA port on the WJ MP204 and connect one of the DATA port on the System Controller with the RS 485 cable Data Multiplex Unit System Controller WJ MP204 WV CU360 Branch Cable RS 485 Cable To use cables locally purchased they must be of the data grade BELDEN 9406 or equivalent The pin assignments and data flow are shown below Internal Diagram No Name Data Flow No b RX B UN IE GND a 1 Controller end Tz 2 RX B WJ MP204 WV CU360 2 1 RX A E 3 RXA WJ MP204 WV CU360 3 2 4 TXB WJ MP204 WV CU360 4 CE P _ TX B e 5 TXA Wy MP204 gt WV CU360 5 6 L TX A 6 GND 6 27 OPERATING PROCEDURES E Controlling the Camera Functions with the Data Multiplex Unit WJ MP204 Before starting operation loosen the screw on the front cover with a screwdriver The Data Multiplex Unit WJ MP204 controls the following Camera selection Alarm reset suspend See page 28 Setup of the WJ MP204 E Controlling the Camera Functions with the System Controller WV CU360 For details refer to the Operating Instructions for the System Controller WV CU360 The System Controller WV CUS60 controls the following Remote control of camera selection Remote control of pan tilt head and camera housing Remote control of camera functi
9. 04 2 1 Place the joint metals on the WJ MP204s as shown below and fix them with the supplied screws M3x6 Note Remove the two screws from the rear of each WJ MP204s and fasten it with the eight supplied Joint metal Remove 2 screws from screws M3x8 the rear beforehand Rack mounting bracket small Mount screw Binding head M3x8 Rack mounting bracket small 2 Install the WJ MP204s with the rack mounting brackets on the rack using Mount screw four screws not supplied Flat head M3x6 Cautions Do not block the ventilation opening or slots in the cover to prevent the appliance from overheating Always keep temperature in the rack within 45 C 113 F Secure the rear of the appliance to the rack by using additional mounting brackets procured locally if the rack is subject to vibration Do not use tapping screws for installing the WJ MP204 on the rack with the rack mounting brackets Rack mounting screws lt SYSTEM CONNECTION E BASIC SYSTEM CONNECTION Panasonic Security Data Mode The Data Multiplex Unit WJ MP204 may be connected to cameras video monitors and system controller WV CU360 as shown in the typical connection example below The ALARM REMOTE connector is described later Refer to the Operating Instructions for each system component for connection and operation Termination ON 4 Line Controller No
10. 1 Termination ON Panasonic Security Data mode Panasonic Security Data mode System Controller WV CU360 Video signal RS485 signal Panasonic Secutiry Data mode 21 O Connecting Two or More Data Multiplex Units to System Controller WV CU360 Panasonic Secuarity Data Mode Len 6 ch 7ch 8 ch VS VD INPUT VS VD OUTPUT DO a Tm MPPE suno li E debes Panasonic Security Termination ON VDOUT Data mode Panasonic Security Data mode Monitor Termination ON Controller No 1 Video signal ARA RS485 signal controller site Panasonic Security Data mode System Controller WV CU360 22 23 O Connecting Two or More Data Multiplex Units to Matrix Switcher WJ SX350 Camera Communication Mode Camera 1ch Camera e 5 ch Q 6 ch e 7ch 8 ch Camera communication mode UHL tine MODE Data Multiplex Unit Termination ON WJ MP204 i i i Unit Address 1 IN 4 E 2 1 IN IN ALARM REMOTE e Q N OAO O O i F Q o E x O O O 55 O elo C e amp TOUT TH KE SPOT ND R DATA MODE Data Mu
11. ATA CAMERA IN COMP m VD2 DATA m VS VD INPUT m CAMERA CONFIG E CAMERA CONFIG DAISY MODE TERMINAL O Camera Communication mode see page 16 19 SYSTEM COMMUNICATION CAM ADDRESS CAM ADDRESS BAUD RATE DATA BIT PARITY CHECK STOP BIT WAIT TIME DELAY TIME XON XOFF ALARM MODE m MONITOR SPOT ALARM DISPLAY m SITE ALARM m TERM ALARM m ALARM OUTPUT L ALARM DATA COMP VD2 DATA m CAMERA IN COMP L VD2 DATA VS VD INPUT DAISY MODE TERMINAL E Displaying the Setup Menu for Panasonic Security Data Mode 1 Check that the cameras and peripherals are connected correctly and securely 2 Switch all the system components on 3 Press the SETUP ESC button for 2 seconds or more The Setup menu appears on the monitor WJ MP204 SETUP MENU X XX COMMUNICATION 3 SYSTEM 4 Move the cursor up or down pressing button 1 or button 2 A 5 Press the SUSPEND SET button The COMMUNICA TION menu or the SYSTEM menu appears on the moni tor as shown below COMMUNICATION UNIT ADDRESS 1 BAUD RATE 9600 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF SYSTEM ALARM MODE ON Y COMP VD2 DATA Y VS VD INPUT VD CAMERA CONFIG y DAISY MODE ON TERMINAL ALARM The following buttons are used with the Setup menu 1 V To move the cursor down 2 A
12. Data Bit Setting 1 Display the COMMUNICATION menu 2 Move the cursor to DATA BIT by pressing button 1 V or button 2 A then select the desired number of data bits 7 or 8 by pressing button 3 or button 4 The initial factory setting is 8 bit 4 Parity Check Setting 1 Display the COMMUNICATION menu 2 Move the cursor to PARITY CHECK by pressing button 1 V or button 2 A then select the desired type of parity check NONE EVEN or ODD by pressing button 3 gt or button 4 The initial factory setting is NONE b Stop Bit Setting 1 Display the COMMUNICATION menu 2 Move the cursor to STOP BIT by pressing button 1 V or button 2 then select the desired number of stop bits 1 or 2 by pressing button 3 or button 4 The initial factory setting is 1 bit 6 Wait Time Setting 1 Display the COMMUNICATION menu 2 Move the cursor to WAIT TIME by pressing button 1 Y or button 2 A then select the desired wait time OFF 100 200 400 or 1000 ms by pressing button 3 gt or button 4 The initial factory setting is OFF No retry 7 Delay Time Setting 1 Display the COMMUNICATION menu 2 Move the cursor to DELAY TIME by pressing button 1 Y or button 2 A then select the desired delay time OFF 10 20 40 or 100 ms by pressing button 3 gt or button 4 The initial factory setting is OFF 8 XON XOFF Setting 1 Display the COMMUNICATION menu 2 Move th
13. IT TIME OFF DELAY TIME OFF XON XOFF NOT USE 3 Move the cursor to the desired item by pressing button 1 V or button 2 then select the desired mode by pressing button 3 or button 4 4 Press the SUSPEND SET button 5 After taking the above steps press the SETUP ESC button for 2 seconds or more Note All the settings must be compatible with the peripherals connected 17 1 Camera Addresses Setting 1 Display the COMMUNICATION menu 2 Move the cursor to CAM ADDRESS by pressing button 1 V or button 2 A press the SUSPEND SET button and then select the desired camera addresses in the range of 1 to 99 or No Camera by pressing button 3 or button 4 COMMUNICATION CAM ADDRESS 1 BAUD RATE 19200 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF DELAY TIME OFF XON XOFF NOT USE CAM ADDRESS CAMERA IN ADDRESS 1CH 1 2CH 2 3CH 3 ACH 4 Note Check before the above setting that the UNIT switch is at 0 For address setting see page 10 Before switching the Data Multiplex Unit back on remember that address setting with the UNIT switch has priority to the above setting 2 Baud Rate Setting 1 Display the COMMUNICATION menu 2 Move the cursor to BAUD RATE by pressing button 1 Y or button 2 A then select the desired baud rate 19200 9600 4800 or 2400 bps by pressing button 3 gt or button 4 The initial factory setting is 19200bps 3
14. ON or OFF by pressing button 3 or button 4 The initial factory setting is ON Terminal Alarm Setting Display the SYSTEM menu Move the cursor to TERM ALARM by pressing button 1 Y or button 2 A then select TERM ALARM ON or OFF by pressing button 3 or button 4 The initial factory setting is ON Alarm Output Data Alarm Output Duration from Alarm Connector Display the SYSTEM menu Move the cursor to ALARM OUTPUT by pressing but ton 1 V or button 2 A then select the desired alarm output duration 1S 30S 40S 50S 1MIN 2MIN 3MIN 4MIN 5MIN EXT or OFF by pressing button 3 or button 4 The initial factory setting is 10S Enable to set by 1 sec ond 1S 30S EXT The alarm signal continues to be output from ALARM REMOTE connector till the alarm is reset The alarm is not automatically reset 1S 5MIN The alarm signal is supplied from ALARM REMOTE connector only for the set time The alarm is automatically reset after the set time The ALARM indicator changes from blink to steady light OFF The alarm signal is not supplied from ALARM REMOTE connector The alarm is not automati cally reset Alarm Data This is to set whether or not the alarm data received from a camera is to be transmitted to the WV CUS60 OFF Select this parameter if the system controller is not connected to the system or if operation is to be controlled via an AV Codec 0S Each time
15. ONFIG CAMERA IN CAM NO 1CH 1CH 2CH 2CH 3CH 3CH ACH ACH 1 Display the SYSTEM menu 2 Move the cursor to CAMERA CONFIG by pressing but ton 1 V or button 2 press the SUSPEND SET button then assign unit numbers 1 to 128 or no camera by pressing button 3 or button 4 Camera numbers are automatically assigned accord ing to the UNIT switch settings 5 Daisy Mode 1 Display the SYSTEM menu 2 Move the cursor to DAISY MODE by pressing button 1 Y or button 2 A then select control mode ON or OFF by pressing button 3 or button 4 The initial factory setting is ON 6 Terminal 1 Display the SYSTEM menu 2 Move the cursor to TERMINAL by pressing button 1 V or button 2 A then select ALARM or REMOTE by pressing button 3 or button 4 The initial factory setting is ALARM Note To switch from ALARM REMOTE IN to ALARM REMOTE OUT shift the internal connector of the WJ MP204 from the ALM IN connector to the ALM OUT connector See page 24 The initial factory setting of ALARM REMOTE connector is ALM IN E Displaying the Setup Menu of Camera Communication Mode 1 Check that the cameras and peripherals are connected correctly and securely 2 Switch all the system components on 3 Press the SETUP ESC button for 2 seconds or more The Setup menu appears on the monitor WJ MP204 SETUP MENU X XX COMMUNICATION SYSTEM 4 Move the cursor up or
16. P Ec EE Den Cae CE CE HE 21 I Basic System CONNECTION s an await oe ete iet ti nS ete des 21 B Alarm Remote Connector vaivenes rasos 24 Bi Connector Selection for Setup Menu Output cococconcccncccnoncnonocconnconnnnnn ccoo nor none 25 p RS485 Terminal ica AA e n NE 25 i Connectionto W CUZGO ini A A AA ke a e ai 26 OPERATING PROCEDURES lt cui ie a e Re e e nn 27 Bi Controlling the Camera Functions with the Data Multiplex Unit WJ MP204 sssseeneeeenm enne 27 Bi Controlling the Camera Functions with the System Controller WV CUS60 essen nennen 27 Heri res ire M NER 27 ALARM CONTROL FUNCTIONS cuicos ccoo stet Le D ere i pede ede ec e ice eee lee ec Da e doc oi Rope ind 28 Ka uu anojr eU 28 B Alarm Operation rete ot eee AE EU EE eee ES 28 ACID EP T 28 B Alarm Suspend np e eie pp dei n f D e E ER e e SA b dad 28 SPECIFICATIONS e et e eb beue bte cct et eben ten cdd i d es 29 STANDARD ACCESSORY nac oe de Uc ee ee ee TRO RE ERR HE URL alee ea ER LER Ee ERN 29 ALL RESEP Si a 29 APPENDIX oasis an eh 2 tom a er o pio oe eee eee 30 PREFACE The WJ MP204 Data Multiplex Unit enables you to remote control multiple surveillance cameras check alarm set tings operate the cameras and control other system com ponents when combined with the WV CU360 System Controller with Panasonic Security Data mode capability Using up to four Data Multiplex Units in dais
17. Panasonic Data Multiplex Unit Operating Instructions Model No WJ B M P204 ALARM ALARM SUSPEND panasonic MP204 Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use ENGLISH VERSION We declare under our sole responsibility that the product to which this declaration relates is in conformity with the standards or other normative documents following the provisions of Directives EEC 73 23 and EEC 89 336 Noi dichiariamo sotto nostra esclusiva responsabilit che il prodotto a cui si riferisce la presente dichiarazione risulta conforme ai seguenti standard o altri documenti normativi conformi alle disposizioni delle direttive CEE 73 23 e CEE 89 336 Wij verklaren als enige aansprakelijke dat het product waarop deze verklaring betrekking heeft voldoet aan de volgende normen of andere normatieve documenten overeenkomstig de bepalingen van Richtlijnen 73 23 EEC en 89 336 EEC Vi erkleerer os eneansvarlige for at dette produkt som denne deklara tion omhandler er i overensstemmelse med standarder eller andre nor mative dokumenter i f lge bestemmelserne i direktivene 73 23 EEC og 89 336 EEC Vi deklarerar h rmed v rt fulla ansvar f r att den produkt till vilken denna deklaration h nvisar r i verensst mmelse med standarddoku ment eller andra normativa dokument so
18. Power Source Power Consumption Camera Input Spot Input VS VD Input Camera Output Spot Output VS VD Output Data Communication Standard Alarm Input Alarm Output Alarm Recover Input Alarm Reset Output Spot Switching Input Alarm Switching Output Unit address Operating for System Ambient Operating Temperature Ambient Operating Humidity Dimensions Weight 220 240 VAC 50 Hz 7W 1 V p p 75 Ox 4 1 V p p 75 Q x 1 VS 1 V p p1 75 Q VD 4 V p p 75 Q x1 1 V p p 75 Q Looped through x4 1 V p p 75 Q x1 Changeable Output from camera input or Spot input VS VD IN Looped through or internal VD 4 V p p 75 Q x 1 Based on RS485 4 Line 2 Line Modular Jack x 1 or 5 pins terminal x 1 4 Alarm Output Remote Input Remote Output selectable 3 1 O C 16 V 100 mA 1 1 0 5 amp O C 16 V 100 mA 4 1 No Voltage Contact 1 O C 16 V 100 mA 1 8 Setting by Unit Switch 9 99 Setting by Setup menu Selection Camera No Voltage Contact Alarm Data Display Reset Suspend Setup Camera Lens Housing PAN TILT External device control 10 C 50 C 14 F 122 F Less than 90 96 210 W x 44 H x 350 D mm 8 9 16 W x1 3 4 H x13 3 4 D 2 6 kg 5 72 lbs 1 Selectable using the mode switch 2 Valid in communication mode 3 Selectable using the Setup menu and internal connector 4 Selectable using an internal switch
19. This permits controlling external devices in case of an alarm Camera site alarm is available to each channel Each alarm signal can be supplied independently from ALARM REMOTE connector by shifting the internal con nector 28 B Alarm Reset O Mode After Alarm Reset The camera picture remains as it is until the alarm is reset e ALARM disappears The figure shown in the place of after the word ALARM is a camera number Alarm signal output stops The alarm indicator stops blinking Reset signal is supplied from the alarm reset output O Manual Reset The following are the steps to reset the alarm Press the ALARM RESET button on the System Controller WV CU360 in Panasonic Security Data mode only Press the ALARM RESET button on the WJ MP204 Signal is sent to the alarm recover input connector Alarm reset command is sent to the RS 485 terminal in camera communication mode only O Auto Reset An alarm is automatically reset when the programmed alarm output time is over The alarm indicator changes from blinking to steady light See pages 14 and 18 Note To go the alarm indicator off take any one of the steps for manual reset E Alarm Suspend Alarms will be ignored when the ALARM SUSPEND button is pressed The alarm suspension mode is reset when the ALARM SUSPEND button is pressed again The alarm sus pend indicator remains lighted during alarm suspend mode SPECIFICATIONS
20. To move the cursor up 3 To select a mode or parameter 4 To select a mode or parameter SUSPEND SET To enter the selections and display the submenu for the item indicated by the mark Y SETUP ESC To return to the previous menu 12 Note To not display the Setup menu for CAMERA OUT pic tures shift the internal switch See page 25 To finalize the settings press the SETUP ESC button for 2 seconds or more while the Setup menu is dis played To use the System Controller WV CU360 for operation refer to its Operating Instructions E Communication Setup of Panasonic Security Data Mode 1 Display the Setup menu 2 Move the cursor to COMMUNICATION by pressing button 1 V or button 2 A Then press the SUSPEND SET button In case of Panasonic Security Data mode the COM MUNICATION menu appears as shown below COMMUNICATION UNIT ADDRESS 1 BAUD RATE 9600 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF 3 Move the cursor to the desired item by pressing button 1 V or button 2 A then select the desired mode by pressing button 3 or button 4 4 Press the SUSPEND SET button 5 After taking the above steps press the SETUP ESC button for 2 seconds or more Note All the settings must be compatible with the peripherals connected The following buttons are used with the Setup menu for the WV CU360 For Panasonic Security Data mode only uP Q DOWN To move t
21. Unit can communicate with the WV CU360 System Controller in Panasonic Security Data mode or Camera Communication mode Both modes require different settings Panasonic Security Data mode This mode lets you Operate multiple cameras and devices via one WV CU360 System Controller Connect up to 16 Data Multiplex Units for Panasonic Security Data mode communication up to 4 in case of the WJ MP204 Set a unit number for each Data Multiplex Unit Synchronize each channel by multiplexing the video signal with the sync signal VD2 Enable cable loss compensation For Panasonic Security Data communication mode refer to the following pages Setup Procedure sese 8 Setting Communication Mode 9 Setting Addresses sss 10 Setup Menu sse 11 Displaying the Setup Menu sss 12 Communication Setup sssuss 12 13 System Setup sss 13 14 15 Basic System Connections ss 21 Connecting Two or More Data Multiplex Units to System Controller WV CU360 22 PRECAUTIONS Refer all work related to the installation of this product to qualified service personnel or system installers Do not block the ventilation opening or slots on the cover To prevent the appliance temperature from rising place the appliance at least 5 cm 2 inches away from the wall Do not d
22. an alarm is detected it is notified to the system controller 1S When an alarm is detected it is notified to the System controller Alarm data on each channel where an alarm is detected is stored for 1 sec ond and the stored alarm data is sent to the System controller 5S When an alarm is detected it is notified to the System controller Alarm data on each channel where an alarm is detected is stored for 5 sec onds and the stored alarm data is sent to the System controller Note To set OS 1S or 5S the system controller set as controller No 1 must be connected to the system Display the SYSTEM menu Move the cursor to ALARM DATA by pressing button 1 V or button 2 A then select the desired alarm data duration OFF OS 1S or 5S by pressing button 3 or button 4 The initial factory setting is 1S 15 2 Comp VD2 Data Setting COMP VD2 DATA CAMERA IN 1CH COMP S VD2 ON DATA ON Camera Input Setting 1 Display the SYSTEM menu 2 Move the cursor to CAMERA IN by pressing button 1 V or button 2 A press the SUSPEND SET button then select the desired channel 1 2 3 or 4 for back ground picture by pressing button 3 or button 4 The initial factory setting is 1CH Cable Compensation Setting 1 Display the SYSTEM menu 2 Move the cursor to COMP by pressing button 1 V or button 2 A press the SUSPEND SET button then select the most suitable
23. at ed OFF The screen continues to display the pictures in the mode selected previously when the alarm is activated T 2 Alarm Display Setting Display the SYSTEM menu Move the cursor to ALARM DISPLAY by pressing button 1 V or button 2 A then select ALARM DISPLAY ON or OFF by pressing button 3 or button 4 so that ALARM appears on the screen or not The initial factory setting is ON Note The figure shown in the place of after the word ALARM is a channel number Site Alarm Setting Display the SYSTEM menu Move the cursor to SITE ALARM by pressing button 1 1 2 Y or button 2 A then select SITE ALARM ON or OFF by pressing button 3 or button 4 The initial factory setting is ON Terminal Alarm Setting Display the SYSTEM menu Move the cursor to TERM ALARM by pressing button 1 Y or button 2 A then select TERM ALARM ON or OFF by pressing button 3 or button 4 The initial factory setting is ON Alarm Output Data Alarm Output Duration from Alarm Connector Display the SYSTEM menu Move the cursor to ALARM OUTPUT by pressing button 1 V or button 2 A then select the desired alarm output duration 1S 30S 40S 50S 1MIN 2MIN 3MIN 4MIN 5MIN EXT or OFF by pressing button 3 or button 4 The initial factory setting is 10S Enable to set by 1 sec ond 1S 30S EXT The alarm signal continues to be output from ALARM REMOTE conne
24. at Dip Switch SW1 is up THROUGH THROUGH tOdO SW1 SETTING ADDRESSES Address setting varies from one communication mode to another The setting should be made by qualified service personnel or system installers E Panasonic Security Data Mode Set each number as follows UNIT Switch Settings of WJ MP204 0 1 2 3 4 5 6 7 8 9 T di Set the Baud nit address number in of a Setup of WJ MP204 Setup 2 3 4 5 6 f 8 reserved menu number Notes Do not set the UNIT switch to position 9 because it is a reserved number When two Units corresponding to Panasonic Security Data or more are connected check that each UNIT switch is set to a number different from those of the others n changing unit addresses using the setup menu set the UNIT switch to position O Keep the power switch in the OFF position while setting unit numbers Addresses cannot be set if power is on For details of setting the System Controller WV CU360 refer to the Operating Instruction for the System Controller O Setting Unit Addresses Turn the UNIT switch till the arrow points the desired number UNIT 907 E Camera Communication Mode Set camera address as follows UNIT Switch Settings of WJ MP204 0 1 2 3 4 5 6 7 8 9 1 Sum 1 5 9 13 17 21 25 29 Prohibit gt Set the rohibition CAMERA 2 number in 2 6 10 14 18 22 26 30 of a S
25. cable length by pressing but ton 3 gt or button 4 S Less than 400 m 1 300 ft M 400 m 1 300 ft to 700 m 2 300 ft L 700 m 2 300 ft to 900 m 3 000 ft When using RG 59U BELDEN 9259 or equivalent cable The initial factory setting is S VD2 Setting Display the SYSTEM menu Move the cursor to VD2 by pressing button 1 V or button 2 press the SUSPEND SET button then select ON OFF or THRU by pressing button 3 or button 4 ON Multiplex sync signals VD2 are generated by synchronizing with the signals sent to the VS VD IN connector If there is no input signal the internally generated sync signal VD2 is multiplexed OFF Sync signal VD2 is not multiplexed THRU The sync signal VD2 sent to the CAMERA OUT connector is multiplexed with the video sig nals If there is no input signal the sync signal VD2 is not multiplexed The initial factory setting is ON Data Setting Display the SYSTEM menu Move the cursor to DATA by pressing button 1 V or button 2 press the SUSPEND SET button then select data communication ON or OFF by pressing but ton 3 gt or button 4 The initial factory setting is ON 3 VS VD Input 1 Display the SYSTEM menu 2 Move the cursor to VS VD INPUT by pressing button 1 V or button 2 A then select VS or VD by pressing button 3 or button 4 The initial factory setting is VD 4 Camera Config CAMERA C
26. ctor till the alarm is reset The alarm is not automatically reset 1S 5MIN The alarm signal is supplied from ALARM REMOTE connector only for the set time The alarm is automatically reset after the set time The ALARM indicator changes from blink to steady light The alarm signal is not supplied from ALARM REMOTE connector The alarm is not auto matically reset OFF 19 Alarm Data This is to set whether or not the alarm data received from a camera is to be transmitted to the WV CU360 POLLING Disables to transmit to the system controller even if an alarm is activated AUTO1 Enables to transmit to the system controller when an alarm is activated AUTO2 Enables to transmit to the system controller when an alarm is activated Ignores an alarm for 5 seconds after it has transmitted Enable to transmit an alarm after it has elapsed for 5 seconds 1 Display the SYSTEM menu 2 Move the cursor to ALARM DATA by pressing button 1 V or button 2 A then select the desired alarm data mode POLLING AUTO1 or AUTO2 by pressing but ton 3 or button 4 The initial factory setting is AUTO2 2 Comp VD2 Data Setting COMP VD2 DATA CAMERA IN 1CH COMP S VD2 ON DATA ON Camera Input Setting 1 Display the SYSTEM menu 2 Move the cursor to CAMERA IN by pressing button 1 V or button 2 A press the SUSPEND SET button then select the desired channel 1 2 3 or 4 for back ground picture b
27. d with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal in A 2 the plug which is marked with the letter N or coloured black The serial number of this product may be found on the bot The wire which is coloured brown must be connected to the terminal tom of the unit i I in the plug which is marked with the letter L or coloured red You should note the serial number of this unit in the space provided and retain this book as a permanent record of your el er rep aca the bru ER i finaani l pen the fuse compartment wi purchase to aid identification in the event of theft a schoweriverand feplace the tuse Model No WJ MP204 j Sea Reever Serial No fuae ea eee eae rane a WARNING To reduce the risk of fire or electric shock do not expose this appliance to rain or moisture CONTENTS PREFACE sito a e e e tette tdm 4 FEATURES c 4 COMMUNIGA TION MODE crnina atan pee ecd et db he ote nel pe A ie 5 PREGCAUTIONS deae uen Hec diee ede pec Ee reb ede Pede eec EO et fe eri e Re et eere dg 5 MAJOR OPERATING CONTOROLS AND THEIR FUNCTIONS conococccoccccocccocconccononnconncnconnnnnnnnnnnnnmn enne trennen neret terne nnne 6 MICA EE 6 E Rear VW EORR ED 7 SETUP PROCEDURE ooo Re ie e d i bred eu esee degebat tL E p e beet 8 DIP SWITCH SETTING
28. e cursor to XON XOFF by pressing button 1 Y or button 2 A then select the desired mode NOT USE or USE by pressing button 3 or button 4 The initial factory setting is NOT USE 18 ll System Setup for Camera 1 Communication Mode Display the Setup menu 2 Move the cursor to SYSTEM by pressing button 1 V or button 2 A then press the SUSPEND SET button In case of Camera Communication mode the SYS TEM menu appears as shown below SYSTEM ALARM MODE ON Y COMP VD2 DATA Y VS VD INPUT VD DAISY MODE ON TERMINAL ALARM 3 Move the cursor to the desired item by pressing button 1 V or button 2 A and then select the desired mode by pressing button 3 or button 4 4 Press the SUSPEND SET button 5 After taking the above steps press the SETUP ESC button for 2 seconds or more Note All the settings must be compatible with the peripherals connected 1 Alarm Mode Setting Monitor Spot Setting ALARM MODE MONITOR SPOT ON ALARM DISPLAY ON SITE ALARM ON TERM ALARM ON ALARM OUTPUT 10S ALARM DATA AUTO2 Display the SYSTEM menu Move the cursor to ALARM MODE by pressing button 1 V or button 2 A press the SUSPEND SET button then select MONITOR SPOT ON or OFF by pressing button 3 or button 4 The initial factory setting is ON ON The screen of the corresponding channel appears on the spot output screen when the alarm is activ
29. ed N1299 2060 YWV8QA5360CN 19 Printed in Japan Gedruckt in Japan Imprim au Japon Impreso en Jap n
30. etup IN OUT Connector 3 Setup 3 7 11 15 19 23 27 31 reserved menu number 4 4 8 12 16 20 24 28 32 Notes Do not set the UNIT switch to position 9 because it is a reserved number When two Units or more are connected check that each UNIT switch is set to a number different from those of the others n changing camera addresses using the setup menu set the UNIT switch to position O Keep the power switch in the OFF position while setting unit numbers Addresses cannot be set if power is on O Setting Unit Addresses Turn the UNIT switch till the arrow points the desired number UNIT 907 NO e w PGA 11 SETUP MENU The Setup menu consists of two main menus one for communication setup for connection to cameras and the system con troller WV CU360 and the other for system setup of the Data Multiplex Unit Each of the main menus consists of submenus The Setup menu varies between Panasonic Security Data mode and Camera Communication mode Refer to the description of communication mode setting with the DIP switches on page 9 il Setup Menu O Panasonic Security Data mode see page 12 15 m COMMUNICATION m UNIT ADDRESS m BAUD RATE r DATA BIT PARITY CHECK Po STOP BIT WAIT TIME SYSTEM ALARM MODE 1 MONITOR SPOT MONITOR SPOT m ALARM DISPLAY SITE ALARM I TERM ALARM m ALARM OUTPUT ALARM DATA m COMP VD2 D
31. he cursor up and down C4 pag e o To select a mode or parameter CAM To enter the selections and display SET the submenu MON To return to the previous menu ESC 13 1 Unit Address Setting 1 Display the COMMUNICATION menu 2 Move the cursor to UNIT ADDRESS by pressing button 1 V or button 2 A then select the desired unit address in the range of 1 to 99 by pressing button 3 or button 4 Notes Check before the above setting that the UNIT switch is at 0 For address setting see page 10 Before switching the Data Multiplex Unit back on remember that address setting with the UNIT switch has priority to the above setting COMMUNICATION UNIT ADDRESS 1 BAUD RATE 9600 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 WAIT TIME OFF 2 Baud Rate Setting 1 Display the COMMUNICATION menu 2 Move the cursor to BAUD RATE by pressing button 1 Y or button 2 A then select the desired baud rate 19200 9600 4800 or 2400 bps by pressing button 3 gt or button 4 The initial factory setting is 9600bps 3 Data Bit Setting Setting is fixed for 8 bit 4 Parity Check Setting 1 Display the COMMUNICATION menu 2 Move the cursor to PARITY CHECK by pressing button 1 V or button 2 A then select the desired type of parity check NONE EVEN or ODD by pressing button 3 or button 4 The initial factory setting is NONE 5 S
32. ltiplex Unit WJ MP204 Unit Address 2 Matrix Switcher WJ SX350 SENE T 4 E Miti vs jJ PUUR zne MODE Termination OFF Camera communi cation mode VDOUT Monitor System Controller Video signal RS485 signal camera site RS485 signal controller site Notes It may occur unstable response of the camera in a daisy chain connection B Alarm Remote Connector Alarm related control signals and remote signals are received via this connector The table below shows pin assignments of the WJ MP204 The initial setting is ALARM INPUT 1 Remove four screws left x 2 right x 2 on both sides of the WJ MP204 2 Remove four screws on the rear panel 3 Slide the panel cover to the front as viewed from the rear of the WJ MP204 4 Remove the connector with cable from CN703 ALM IN and attach it to CN702 ALM OUT Notes The ALARM REMOTE connector can be set to ALARM or REMOTE on the system setup menu Terminals 6 to 9 in the figure below are set to ALARM INPUT default To use them as remote input terminals change the TERMINAL parameter on the System menu to REMOTE
33. ly the RS485 terminal Panasonic Security Data mode Use only the Data port Dip Switches MODE These switches are used to select the mode Signal Ground Terminal SIGNAL GND 20 Power Cord SETUP PROCEDURE Follow the procedures below for setup Power Switch LED 1 Press the Power Switch back to the OFF position Power Switch Check that the Power Switch LED is off ALARM Oreset Osuspeno OSET UP SET ESC OA o l 2 Setthe MODE Switches as follows Select an operation mode using the MODE Switches on the rear panel See page 9 for details Communication mode This mode must be selected whenever this data multi plexer unit is used Set the following in communication using the DATA Port or RS485 terminal Termination ON or OFF full duplex or half duplex Set the type of sync signal to be output from the Data Multiplex Unit Set it in supplying the sync signal from the VS VD OUT connector to other devices 3 Set the UNIT Switch Set address unit address or camera addresses using the UNIT Switch on the front panel The addresses to be set vary depending on the communication mode set See page 10 for details 4 Press the Power Switch down to the ON position Check that the Power Switch LED lights up 5 Set parameters on the Setup menu Set parameters on the Setup menu as required to use the Data Multiplex Unit The contents of the Setup menu vary depending on the communication
34. m framst lls i EEC direktiv nr 73 23 och 89 336 Ilmoitamme yksinomaisella vastuullamme ett tuote jota tama ilmoitus koskee noudattaa seuraavia standardeja tai muita ohjeellisia asiakirjoja jotka noudattavat direktiivien 73 23 EEC ja 89 336 EE s d ksi Vi erkl rer oss alene ansvarlige for at produktet som denne erkl ringen gjelder for er i overensstemmelse med f lgende normer eller andre nor mgivende dokumenter som f lger bestemmelsene i direktivene 73 23 EEC og 89 336 EEC FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CARE FULLY This appliance is supplied with a moulded three pin mains plug for your safety and convenience A 13 amp fuse is fitted in this plug Should the fuse need to be replaced please ensure that the replacement CAUTION TOREDUCE THERISK CF E ECTRIC SHOCK fuse has a rating of 13 amp and that it is approved by ASTA or BSI to NOT REMOVE COVER BACK BS1362 LO R Check for the ASTA mark or the BSI mark Y on the body of the NOUSER SERVICEABLE PARTS INSIDE fuse 7 If the plug contains a removable fuse cover you must ensure that it is REFER SERVIONG TOQUALIRED SERVICE PERSONNEL refitted when the fuse is replaced If you lose the fuse cover the plug must not be used until a replacement cover is obtained A replacement fuse cover can be purchased from your local Panasonic The lightning flash with arrowhead symbol cd
35. modes and parameters in the Setup menu When setting a numerical value such as the Camera number or address pressing this button will increment the value Alarm Indicator ALARM This indicator blinks when the alarm is activated It changes to steady light when the alarm is automatically reset Alarm Suspend Indicator ALARM SUSPEND This indicator lights up while the alarm is suspended It goes off when the function is reset Note To use the switch and the buttons in and 6 above remove the front cover by loosening the screw with a screwdriver For further informa tion see page 27 E Rear View 9 Camera Input Connectors 1 4 CAMERA IN 1 2 3 4 These connectors accept the composite video signal from the camera Camera Output Connectors 1 4 CAMERA OUT 1 2 3 4 The video signal connected to the Camera Input Connector CAMERA IN 1 2 3 4 is looped through to these connectors Video Input Connector SPOT IN Used when multiple Data Multiplex Units are connect ed Note To connect multiplex Data Multiplex Units set DAISY MODE in the System menu to ON 2 Video Output Connector SPOT OUT This connector supplies the video output signal for the spot monitor It is also used when connecting multiple Data Multiplex Units 43 VS VD Input Connector VS VD IN Accepts the video sync signal VS or a vertical drive signal VD supplied by external devices to
36. ng is ON 3 VS VD Input 1 Display the SYSTEM menu 2 Move the cursor to VS VD INPUT by pressing button 1 V or button 2 A then select VS or VD by pressing button 3 or button 4 The initial factory setting is VD 4 Daisy Mode 1 Display the SYSTEM menu 2 Move the cursor to DAISY MODE by pressing button 1 Y or button 2 A then select control mode ON or OFF by pressing button 3 or button 4 The initial factory setting is ON 5 Terminal 1 Display the SYSTEM menu 2 Move the cursor to TERMINAL by pressing button 1 V or button 2 A then select ALARM or REMOTE by pressing button 3 or button 4 The initial factory setting is ALARM Note To switch from ALARM REMOTE IN to ALARM REMOTE OUT shift the internal connector of the WJ MP204 from the ALM IN connector to the ALM OUT connector See page 24 The initial factory setting of ALARM REMOTE connector is ALM IN 20 INSTALLATION The installation described below should be made by quali fied service personnel or system installers E Mounting in the Rack Remove the four rubber feet by removing the four screws from the bottom of the WJ MP204 Rubber feet O Mounting One WJ MP204 with the WV Q204 1 1 Fix the mounting brackets large and small on both sides of the WJ MP204 with the eight supplied screws M3x8 Rack mounting bracket small Mounting two WJ MP204s With the WV rael large Q2
37. ons Alarm reset alarm suspend Setup of the Data Multiplex Unit WJ M204 and cameras The functions differ from one type of camera to anoth er E Camera Selection Select a camera number using the camera selection but tons 1 W 2 A 3 and 4 OY 1 OA 2 ALARM CONTROL FUNCTIONS E Alarm Input The Data Multiplex Unit processes the following alarms As to setting see page 14 18 and 19 Camera Site Alarm Alarm multiplexed with video signals from the camera Terminal Alarm Alarm received from the ALARM REMOTE connector E Alarm Operation ALARM MODE set to ON on the Setup menu See pages 14 and 18 for details Alarm indicator blinks Alarm data is transmitted to the system controller and other system units MONITOR SPOT set to ON on the Setup menu See pages 14 and 18 for details The camera pictures change automatically to the spot where the alarm is activated The camera pictures change to the preset position when the alarm is activated in Panasonic Security Data mode ALARM DISPLAY set to ON on the Setup menu See pages 14 and 18 e ALARM appears on the screen ALARM blinks in alarm ON mode Note The figure shown in the place of after the word ALARM is a channel number vol ALARM 001 y Yr ALARM OUTPUT set to EXT or 1S 5MIN on the Setup menu See pages 14 and 18 Alarm signal is supplied from the alarm output connec tor
38. rop metallic parts through slots This could permanently damage the appliance Turn the power off immediately and refer servicing to qualified service personnel Do not attempt to disassemble the appliance To prevent electric shock do not remove screws or covers There are no user serviceable parts inside Refer main tenance to qualified service personnel Handle the appliance with care Do not strike or shake as this may damage the appli ance Camera Communication mode This mode lets you Extend the distance between the cameras and the WJ MP204 Data Multiplex Unit by RS 485 cables Control multiple cameras installed at a distance of up to 1200 m 4000 ft from the Data Multiplex Unit by connecting an AV codec Set or change camera address from the Setup menu of the Data Multiplex Unit Synchronize each channel by multiplexing the video signal with the sync signal VD2 Enable cable loss compensation For Camera Communication mode refer to the following pages Setup Procedure miccional 8 Setting Communication Mode 9 Setting Addresses oniiir an an 10 Setup M nu inicio initial 11 Displaying the Setup Menu 16 Communication Setup susuess 16 17 System Setup sse 18 19 Connecting Two or More Data Multiplex Units to Matrix Switcher WJ SX350 oooocccoocccococccconancccnncnon 23 Do not expose the appliance to wa
39. synchro nize the Data Multiplex Unit with other devices Notes Connect a device supplying an external sync sig nal that complies with the CCIR specifications Do not input signals having a high jitter content such as VTR playback signals To input a vertical drive signal set VS VD INPUT in the System menu to VD VS ND Output Connector VS VD OUT This connector is used to supply the sync signal input to the VS VD IN connector or the internally generated sync signal VD to other devices Note Set MODE Switch 1 to OFF THROUGH in sup plying the signals input to the VS VD IN connector to other devices Set MODE Switch 1 to ON VD in supplying the internally generated reference sync signal VD to other devices 5 Alarm Remote Connector ALARM REMOTE The factory default setting is ALARM input For remote input set TERMINAL in the System menu to REMOTE Can also be used as ALARM REMOTE output terminal by moving an internal connector Refer to page 24 for details RS485 Terminal RS485 This terminal is used to exchange control data with the camera site via Camera Communication mode 7 Data Port DATA This port is used to exchange control data with the WV CU360 System Controller in Panasonic Security Data mode Note Cannot use both RS485 Terminal and Data port at the same time It can be distributed correspond ing to the communication mode as follows Camera Communication Mode Use on
40. ter or moisture nor try to operate it in wet areas Do take immediate action if the appliance becomes wet Turn the power off and refer servicing to qualified service personnel Moisture can damage the appliance and also cause electric shock Do not use strong or abrasive detergents when cleaning the appliance body Use a dry cloth to clean the appliance when it is dirty When the dirt is hard to remove use a mild detergent and wipe gently Do not operate the appliance beyond its specified temperature humidity or power source ratings Do not use the appliance in an extreme environment where high temperature or high humidity exists Use the appliance at temperatures within 10 C 50 C 14 F 122 F and a humidity below 90 96 The input power source for this appliance is 220 240 V AC 50 Hz ALARM ALARM SUSPEND lata Multiplex Unit WJ MP204 D Power Switch POWER ON OFF Press once to turn on the Data Multiplex Unit The switch remains down and the LED lights up Press again to turn off the unit The switch comes up Mf Note To prevent that the power of the Data Multiplex Unit is turned off accidentally install the supplied switch protector Unit Switch 0 8 UNIT Sets the addresses given below Turn the switch to align the desired number with the arrow Data Multiplex Unit address Camera addresses for CAMERA IN 1 4 Note Keep the Po
41. top Bit Setting 1 Display the COMMUNICATION menu 2 Move the cursor to STOP BIT by pressing button 1 V or button 2 A then select the desired number of stop bits 1 or 2 by pressing button 3 or button 4 The initial factory setting is 1 bit 6 Wait Time Setting 1 Display the COMMUNICATION menu 2 Move the cursor to WAIT TIME by pressing button 1 V or button 2 A then select the desired wait time OFF 100 200 400 or 1000 ms by pressing button 3 gt or button 4 The initial factory setting is OFF No retry E System Setup for Panasonic Security Data Mode 1 Display the Setup menu 2 Move the cursor to SYSTEM by pressing button 1 V or button 2 A then press the SUSPEND SET button n case of Panasonic Security Data mode the SYS TEM menu appears as shown below SYSTEM ALARM MODE ON y COMP VD2 DATA Y VS VD INPUT VD CAMERA CONFIG y DAISY MODE ON TERMINAL ALARM 3 Move the cursor to the desired item by pressing button 1 Y or button 2 A then then select the desired mode by pressing button 3 or button 4 4 Press the SUSPEND SET button 5 After taking the above steps press the SETUP ESC button for 2 seconds or more Note All the settings must be compatible with the peripherals connected 14 1 Alarm Mode Setting 1 2 Monitor Spot Setting ALARM MODE MONITOR SPOT ALARM DISPLAY SITE ALARM ON TERM ALARM ON ALARM OUTPUT 10S
42. wer switch in the OFF position while Setting addresses Alarm Reset Button ALARM RESET This button resets the Active Alarm Mode Pressing this button goes off the Alarm indicator and replaces the Alarm indication on the monitor screen 4 Alarm Suspend Set Button ALARM SUSPEND SET Pressing this button will suspend alarm input alarm input will be ignored Pressing it again will reset the function In the Setup menu opens submenus for more detailed settings Menu items having a submenu are identified by a return symbol at the end of the line 5 Setup ESC Button SETUP ESC Pressing this button for 2 seconds or more opens the Setup menu of the Data Multiplex Unit If pressed for less than 1 second it functions as the Escape button and returns you to the previous menu To close the Setup menu when the setup is completed press the button for 2 seconds or more Note Make sure to distinguish between 1 second and 2 second operation of this button Camera Selection Buttons Select the camera for display of live picture When the Setup menu is displayed on the monitor these buttons function as follows Cursor button V Moves the cursor down Cursor button A Moves the cursor up Decrement button Selects modes and parameters in the Setup menu When setting a numerical value such as the camera number or address pressing this button will decrement the value Increment button Selects
43. within an equilateral triangle is interned to IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCK alert the user to the presence of uninsulated ET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE dangerous voltage within the product s REMOVED AND THE PLUG CUT OFF AND DISPOSED c E nclosure that mav be of sufficient magni THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE fud um ET t ay isk of electric sh E CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET UUE 10 CONSUULE A FISK OF BTOGITTIG SHOCR TO If a new plug is to be fitted please observe the wiring code as shown persons below If in any doubt please consult a qualified electrician The exclamation point within an equilateral L VARNING This apparatus Must pg sarthed triangle is intended to alert the user to the IMPORTANT presence of important operating and mainte The wires in this mains lead are coloured in accordance with the follow nance servicing instructions in the litera ing code i i l Green and yellow Earth ture accompanying the appliance Blue Neutral Brown Live As the colours of the wire in the mains lead of this appliance may not a correspond with the coloured markings identifying the terminals in your CAUTION plug proceed as follows Before attempting to connect or operate this product The wire which is coloured green and yellow must be connected to please read the label on the bottom the terminal in the plug which is marke
44. y chain con nection allows expansion of the system to include up to 16 cameras The distance between the system and the cam eras can be extended by connecting an AV Codec or simi lar device The WJ MP204 and other devices compatible with Panasonic Security Data mode have the logo PS DataBh FEATURES The WJ MP204 offers the following functions Panasonic Security Data mode with WV CU360 con nected Camera Communication mode with WJ SX350 con nected via RS 485 Camera channel selection Alarm resetting and suspension Communication and system setup Remote control of the cameras using the WV CU360 System Controller with Panasonic Security Data mode capability including Camera settings Pan Tilt Head and Camera Housing Wiper Defroster etc Motorized Zoom Lens Focus Zoom lris etc Camera setup Camera Spot function Allows you to display on the monitor any camera image selected on the WJ MP204 Data Multiplex Unit or the WV CU360 System Controller Alarm function Performs the following operations in response to alarm input to the WJ MP204 Data Multiplex Unit Activates the camera preset function and displays the image of the camera at the preset position on the moni tor Outputs an alarm signal from the Alarm Remote con nector to external devices to notify them of the alarm Accepts alarm input multiplexed with video signal from the camera COMMUNICATION MODE The WJ MP204 Data Multiplex
45. y pressing button 3 or button 4 The initial factory setting is 1CH Cable Compensation Setting 1 Display the SYSTEM menu 2 Move the cursor to COMP by pressing button 1 V or button 2 press the SUSPEND SET button then select the most suitable cable length by pressing but ton 3 gt or button 4 S Less than 400 m 1 300 ft M 400 m 1 300 ft to 700 m 2 300 ft L 700 m 2 300 ft to 900 m 3 000ft When using RG 59U BELDEN 9259 or equivalent cable The initial factory setting is S VD2 Setting 1 Display the SYSTEM menu 2 Move the cursor to VD2 by pressing button 1 V or button 2 press the SUSPEND SET button then select ON OFF or THROUGH by pressing button 3 or button 4 ON Multiplex sync signals VD2 are generated by syn chronizing with the signals sent to the VS VD IN connector If there is no input signal the internally generated sync signal VD2 is multiplexed OFF Sync signal VD2 is not multiplexed THRU The sync signal VD2 sent to the CAMERA OUT connector is multiplexed with the video signals If there is no input signal the sync signal VD2 is not multiplexed The initial factory setting is ON Data Setting 1 Display the SYSTEM menu 2 Move the cursor to DATA by pressing button 1 V or button 2 press the SUSPEND SET button then select data communication ON or OFF by pressing but ton 3 gt or button 4 The initial factory setti