Home

DVI 110 DVI HDMI DVI Signal Regenerator User Guide

image

Contents

1. 1 Signal Eye Pattern SR Re ee 1 Before Regeneration oooicoiicoinniniconiccicoccccccninos 1 After Regeneration ooocicccncoicconccinccocnccccnccinnnos 1 Eat Siria 2 Application Diagrams 2 Installation 4 Front and Rear Panel Features and Connections 4 Connecting the DVI 110 6 Reference Information 7 SpECITICATIQNS israel 7 Part NUM GMS sh cisne 9 Included Parts mistica 9 Optional Accessories 9 Cables and Adapters 9 Mounting the DVI 110 10 Tabletop Us condones intro hu 10 Rack MOUNINO erien 10 Furniture Mounting 11 DVI 110 Contents v DVI 110 Contents vi Introduction This section gives an overview of the Extron DVI 110 Signal Regenerator and provides application examples The following topics are covered e About this Guide e About the DVI 110 Signal Regenerator e Application Diagrams About this Guide This guide describes the functionality of the DVI 110 and provides procedures for connecting and operating it In the guide the terms regenerator and DVI 110 are used interchangeably to refer to the product About the DVI 110 Signal Regenerator The Extron DVI 110 is a compact 1 inch 2 5 cm high one eighth rack wide DVI signal regenerator that maximizes the quality of a digital signal at
2. Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised 3 Mechanical loading When mounting the equipment in the rack ensure that uneven mechanical loading does not cause a hazardous condition 4 Circuit overloading When connecting the equipment to the supply circuit consider the effect that circuit overloading might have on overcurrent protection and supply wiring Consider the equipment nameplate ratings when addressing this concern 5 Reliable earthing grounding Maintain reliable grounding of rack mounted equipment Pay particular attention to supply connections other than direct connections to the branch circuit for example use of power strips DVI 110 Reference Information 10 Rack mounting procedure For optional rack mounting mount the DVI 110 on one of the available rack shelves On the standard 9 5 or 6 inches deep rack shelf the DVI 110 mounts in one of eight possible locations to the rear of the rack Both front false faceplates use 2 screws Figure 7 N Use 2 mounting holes on opposite corners o 1 4 Rack Width E Front False IS Faceplate A Oo DA oF o 70 Qleoooe P 3 A 1 2 Rack Width Front False Faceplate 2 4 40 x 3 16 Screws Leeecee gt 1U Universal Rack Shelf Mounting the DVI 110 on a Standard 9 5 Inches Deep Rack Shelf If rubber feet are attac
3. DDC channels are buffered allowing pass through of EDID and HDCP information between the source and the display e Enclosure Compact 1 inch 2 5 cm high one eighth rack wide and 3 inches 7 6 cm deep metal enclosure e Rack and furniture mounting The regenerator can be mounted on a rack shelf or under a desk or podium e Power supply included An external universal UL energy verified 12 VDC LPS Class 2 1 A power supply accepts 100 to 240 VAC current providing worldwide compatibility and low power consumption e HDMI signal support Fully supports HDMI signals including embedded audio when used with an optional Extron HDMI to DVI adapter Application Diagrams The following diagrams show examples of how the DVI 110 can be connected Extron DVI 101 DVI Equalizer Short DVI Patch Cable 15 4 5 m max Extron DVID SL Pro Series 200 61 m max Laptop with Projector Short DVI Patch Cable 4 DVI Output 15 4 5 m max Extron DVI 110 DVI Regenerator Figure 2 Using the DVI 110 with a DVI 101 Equalizer DVI 110 Introduction 2 DVI F F AAP Laptop with Short DVI DVI Output Patch Cable Extron DVID SL Pro 50 DVI Cable DVI 110 DVI Regenerator Short DVI Patch Cable Extron SW 4 DVI A DVI Switcher W Audio Display w DVI Input amp Audio Figure 3 Using the DVI 110 with a DVI Switcher DVI 110 Introduction In
4. DVI and HDMI DVI 110 DVI Signal Regenerator Extron DVI D OUTPUT ater POWER DVD INPUT 0 4A MAX DVI 110 gt Extron Electronics INTERFACING SWITCHING AND CONTROL 68 1974 01 Rev A Safety Instructions English This symbol is intended to alert the user of important operating and mainte nance servicing instructions in the literature provided with the equipment This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may present a risk of electric shock Caution Read Instructions Read and understand all safety and operating instructions before using the equipment Retain Instructions The safety instructions should be kept for future reference Follow Warnings Follow all warnings and instructions marked on the equipment or in the user information Avoid Attachments Do not use tools or attachments that are not recommended by the equipment manufacturer because they may be hazardous Consignes de S curit Francais Ce symbole sert avertir l utilisateur que la documentation fournie avec le mat riel contient des instructions importantes concernant l exploitation et la maintenance r paration Ce symbole sert avertir l utilisateur de la pr sence dans le bo tier de l appareil de tensions dangereuses non isol es posant des risques d lectrocution Attention Lire les instructions Prendre connaissance de tout
5. reparaci n mantenimiento de este equipo ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos Ranuras y aberturas Si el equipo posee ranuras o orificios en su caja alojamiento es para evitar el sobrecalientamiento de componentes internos sensibles Estas aberturas nunca se deben obstruir con otros objetos Bater a de litio Existe riesgo de explosi n si esta bater a se coloca en la posici n incorrecta Cambiar esta bater a nicamente con el mismo tipo o su equivalente recomendado por el fabricante Desachar las bater as usadas siguiendo las instrucciones del fabricante ae ER REHEAT LARMES ER SU AAR RH RAR AR OBR AEE OH ARES MA o BARR ZAR AAA BE a Be TF BRAWE FUREUR o ZER EUA RENE HEIA o IS EAS RET KSA DUR fo AE ATA BRL APE HLS LA BL EME AAA OR EUR AE PEPE MAL SR AE BENE At BRAD AES ADE BE FREE PASO AEH a AT AR SNE SHH ie FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation The Class A limits are design
6. nicht ausdr cklich vom Hersteller empfohlen wurden da diese eine Gefahrenquelle darstellen k nnen Instrucciones de seguridad Espa ol Este s mbolo se utiliza para advertir al usuario sobre instrucciones impor A tantes de operaci n y mantenimiento o cambio de partes que se desean destacar en el contenido de la documentaci n suministrada con los equipos Precaucion Leer las instrucciones Leer y analizar todas las instrucciones de operaci n y seguridad antes de usar el equipo Conservar las instrucciones Conservar las instrucciones de seguridad para futura consulta Obedecer las advertencias Todas las advertencias e instrucciones marcadas en el equipo o en la documentaci n del usuario deben ser obedecidas Este s mbolo se utiliza para advertir al usuario sobre la presencia de elemen tos con voltaje peligroso sin protecci n aislante que puedan encontrarse dentro de la caja o alojamiento del producto y que puedan representar riesgo de electrocuci n Evitar el uso de accesorios No usar herramientas o accesorios que no sean especificamente recomendados por el fabricante ya que podrian implicar riesgos REM HI AN PES ERP AA RAN OR AX SUS SSAA RENAN AREER AMAR NEAR HPE RAI EA ee AM FRA o PREFER PNUD REA WTA OSA Er Lae RE fn e PIKE MBCA HEE LA BGR IMR DAMES EK Warning Power sources This equipme
7. the beginning of its path by regenerating the signal The DVI 110 reshapes a poor quality output signal providing optimal image quality for HDTV signals Signal Eye Pattern The following illustrations show the eye pattern of DVI output from a test generator before and after regeneration via a DVI 110 An eye pattern is a representation of a digital signal on an oscilloscope in which a digital data signal is repetitively sampled Distortion in the signal waveform due to interference and noise appears as a closing of the eye pattern as shown in the Before Regeneration illustration below on the left After the signal passes through the DVI 110 and is regenerated shown in the After Regeneration illustration below on the right the eye appears more open indicating a clear undistorted signal Acq Limit Test Waveforms 1000 Acq Limit Test Waveforms 1000 Before Regeneration After Regeneration Figure 1 Eye Pattern of a Signal Before and After Regeneration via the DVI 110 DVI 110 Introduction 1 Features e Output resolutions Supports resolutions up to 1080p at 60 Hz and computer video signals up to 1920x1200 e Power Signal indicator The bicolored LED on the front panel lights amber to indicate that power is on and green to indicate source signal presence e Data rates Supports data rates of up to 4 95 Gbps 1 65 Gbps per color e Supports DDC and HDCP
8. un ype equivalent recommande par le constructeur Mettre au reut les batteries usagees conformement aux instructions du fabricant Vorsicht Stromquellen Dieses Ger t sollte nur ber die auf dem Produkt angegebene Stromquelle betrieben werden Dieses Ger t wurde f r eine Verwendung mit einer Hauptstromleitung mit einem geerdeten neutralen Leiter konzipiert Der dritte Kontakt ist f r einen ErdanschluB und stellt eine Sicherheitsfunktion dar Diese sollte nicht umgangen oder auBer Betrieb gesetzt werden Stromunterbrechung Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels Netzkabel sollten stets so verlegt werden daB sie nicht im Weg liegen und niemand darauf treten kann oder Objekte darauf oder unmittelbar dagegengestellt werden k nnen Wartung Alle WartungsmaBnahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger t selbst ffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und ffnungen Wenn das Ger t Schlitze oder L cher im Geh use aufweist dienen diese zur Vermeidung einer Uberhitzung der empfindlichen Teile im Inner
9. 11 7655 81 3 3511 7656 FAX 971 4 2991800 971 4 2991880 FAX 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX 400 883 1568 Inside China Only 86 21 3760 1568 86 21 3760 1566 FAX 800 633 9876 800 3987 6673 Inside USA Canada Only Inside USA Canada Only Inside Europe Only 1 714 491 1500 1 714 491 1517 FAX 1 919 863 1794 1 919 863 1797 FAX 31 33 453 4040 31 33 453 4050 FAX 2010 Extron Electronics All rights reserved Www extron com
10. Video Maximum data rate 4 95 Gbps 1 65 Gbps per color Maximum pixel clock 165 MHz Resolution range ccccceceeeseeees Up to 1920x1200 or 1080p 60 Hz FORM AUS Suns RGB and YCbCr digital video STAM GabOS sec de DVI 1 0 HDMI 1 2 Video input Number signal type 0 eeee 1 single link DVI D or HDMI CONNECIONS assunto 1 female DVI I Input cable length Up to 15 4 5 m at 1920x1200 or 1080p 60 Hz Video output Number signal type oooioniccnccoo 1 single link DVI D or HDMI CONN CIONS oiya iesiri 1 female DVI I General A Supplied by an external power supply External power supply 100 VAC to 240 VAC 50 60 Hz external to 12 VDC LPS Class 2 1 A regulated Power input requirements 12 VDC 0 4 A from an external power supply Temperature humidity o oo Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing A E S Convection no vents Mounting Raek MOUNT rorirori anu Yes with optional rack shelf kit Furniture MOUNE ansis Yes with optional mounting kit Enclosure type Metal Enclosure dimensions 1 0 H x 2 2 W x 3 0 D one eighth rack wide 2 5 cm H x 5 6 cm W x 7 6 cm D Product Welghtisensssnesermnns 0 4 lbs 0 2 kg Shipping weight 2 lbs 1 kg DVI 110 Reference Information 7 VID atl ON sims ISTA 1A in carton International Safe Transit Associ
11. ation Regulatory compliance Sal OLY ie re sen CE c UL UL EMV EME 00 ctas CE C tick FCC Class A ICES VCCI MB muse 30 000 hours Warranty gs nn mme 3 years parts and labor NOTES All nominal levels are at 10 Specifications are subject to change without notice DVI 110 Reference Information 8 Part Numbers Included Parts These items are included with DVI 110 Replacement Included Parts Part Numbers DVI 110 DVI Signal Regenerator 60 1145 01 PS 1210 C 12 VDC LPS Class 2 1 A external power 70 775 01 supply with captive screw connector IEC power cord DVI 110 Setup Card Rubber feet self adhesive 4 not attached Optional Accessories These items are optional and may be ordered separately Accessories Part Numbers DVI 101 Cable Equalizer 60 873 01 RSU 129 9 5 deep 1U Universal Rack Shelf Kit 60 190 01 RSB 129 9 5 deep 1U Basic Rack Shelf 60 604 02 RSU 126 6 deep 1U Universal Rack Shelf Kit 60 190 10 RSB 126 6 deep Basic 1U Basic Rack Shelf 60 604 1 1 RSF 123 3 5 deep 1U Rack Shelf Kit 60 190 20 RSB 123 3 5 deep 1U Basic Rack Shelf 60 604 21 MBU 125 Under desk mounting kit 70 077 01 MBB 100 Back of the Rack Kit 70 367 01 Cables and Adapters The following table lists cables and adapters that are available for the DVI 110 For a complete listing of cables visit the Extron web site at www extron com Cable or Adapter Part Number IN9700 Series DVI 26 584 xx HDMI DVI D Seri
12. ck shield DDC data Ground 5 V TMDS clock CEC control Hot plug TMDS clock detect Figure 5 DVI Connector Pin Assignments pvi D input connector Plug the cable from the source device into this single link format female DVI connector The table above shows the DVI pin configuration NOTE Although this is actually a DVI I connector its analog pins are not enabled Only DVI D signals are accepted Power connector Plug the external 12 V power supply provided with the unit into this 2 pole captive screw connector The figure below shows how to wire the connector Smooth Ridges L i OEY A A SECTION A A oo Power Supply Output Cord Tie Wrap gt ane 5 mm Max LT Captive Screw Connector Figure 6 Wiring the Power Connector DVI 110 e Installation 5 CAUTIONS When you are connecting the power supply voltage polarity is extremely important Applying power with incorrect voltage polarity could damage the power supply and the regenerator Identify the negative lead by the ridges on the side of the cord see the illustration on page 5 To verify the polarity before connection plug in the power supply with no load and check the output with a voltmeter Do not tin the stripped power supply leads before attaching the captive screw connector Tinned wires are not secure in the captive screw connectors and could be pulled out Do not permanen
13. ed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure compliance with FCC emissions limits For more information on safety guidelines regulatory compliances EMI EMF compliance accessibility and related topics click here Notational Conventions Used in this Guide TIP A tip provides a suggestion to make setting up or working with the device easier NOTE A note draws attention to important information CAUTION A caution warns of things or actions that might damage the equipment WARNING A warning warns of things or actions that might cause injury death or other severe consequences Copyright 2010 Extron Electronics All rights reserved Trademarks All trademarks mentioned in this guide are the properties of their respective owners Contents Introduction se eee 1 Aboutthi GUIDES o Mth Oe Mel rele Be 1 About the DVI 110 Signal Regenerator
14. en Diese Offnungen d rfen niemals von anderen Objekten blockiert werden Litium Batterie Explosionsgefahr falls die Batterie nicht richtig ersetzt wird Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp der auch vom Hersteller empfohlen wird Entsorgen Sie verbrauchte Batterien bitte gem B den Herstelleranweisungen Advertencia Alimentaci n el ctrica Este equipo debe conectarse nicamente a la fuente tipo de alimentaci n el ctrica indicada en el mismo La alimentaci n el ctrica de este equipo debe provenir de un sistema de distribuci n general con conductor neutro a tierra La tercera pata puesta a tierra es una medida de seguridad no puentearia ni eliminaria Desconexi n de alimentaci n el ctrica Para desconectar con seguridad la acometida de alimentaci n el ctrica al equipo desenchufar todos los cables de alimentaci n en el panel trasero del equipo o desenchufar el m dulo de alimentaci n si fuera independiente o desenchufar el cable del recept culo de la pared Protecci n del cables de alimentaci n Los cables de alimentaci n el ctrica se deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos Reparaciones mantenimiento Solicitar siempre los servicios t cnicos de personal calificado En el interior no hay partes a las que el usuario deba acceder Para evitar riesgo de electrocuci n no intentar personalmente la
15. es HDMI to DVI D up to 50 in length 26 614 xx HDMIF DVIDM HDMI female to DVI D male adapter 26 616 01 HDMIM DVIDF HDMI male to DVI D female adapter 26 617 01 HDMIF DVIDF HDMI female to DVI D female adapter 26 618 01 DVID SL Series DVI up to 200 in length 26 649 xx HDMI M M Series HDMI male to HDMI male up to 200 in length 26 650 xx DVI 110 Reference Information Mounting the DVI 110 The DVI 110 can be mounted on a rack shelf or under furniture or it can be placed on a table top Extron has a variety of optional rack shelf and furniture mounting kits that can be used with the DVI 110 See Optional Accessories in the Reference Information section for information on the mounting products available for the DVI 110 Tabletop Use Four self adhesive rubber feet are included with the DVI 110 For tabletop use attach one foot at each corner on the bottom surface of the unit Rack Mounting UL rack mounting guidelines The following Underwriters Laboratories UL guidelines apply to the safe installation of the equipment in a rack 1 Elevated operating ambient temperature If the equipment is installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient temperature Therefore install the equipment in an environment compatible with the maximum ambient temperature specified by Extron Tma 122 F 50 C 2 Reduced air flow
16. es les consignes de s curit et d exploitation avant d utiliser le mat riel Conserver les instructionse Ranger les consignes de s curit afin de pouvoir les consulter l avenir Respecter les avertissements Observer tous les avertissements et consignes marqu s sur le mat riel ou pr sent s dans la documentation utilisateur Eviter les pi ces de fixation Ne pas utiliser de pi ces de fixation ni d outils non recommand s par le fabricant du mat riel car cela risquerait de poser certains dangers Sicherheitsanleitungen Deutsch Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung Instandhaltung geben Dieses Symbol soll den Benutzer darauf aufmerksam machen daB im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das Ger t zum ersten Mal verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zur ckgreifen k nnen Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise und Anleitungen auf dem Ger t oder in der Benutzerdokumentation Keine Zusatzger te Verwenden Sie keine Werkzeuge oder Zusatzger te die
17. gn the mounting screws with the slots in the brackets and place the unit against the surface with the screws through the bracket slots Slide the unit slightly forward or back then tighten all four screws to secure it in place DVI 110 Reference Information 12 Extrone Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase In the event of malfunction during the warranty period attributable directly to faulty workmanship and or materials Extron Electronics will at its option repair or replace said products or components to whatever extent it shall deem necessary to restore said product to proper operating condition provided that it is returned within the warranty period with proof of purchase and description of malfunction to USA Canada South America and Central America Extron Electronics 1001 East Ball Road Anaheim CA 92805 U S A Europe Africa and the Middle East Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands Asia Extron Asia 135 Joo Seng Road 04 01 PM Industrial Bldg Singapore 368363 Singapore Japan Extron Electronics Japan Kyodo Building 16 Ichibancho Chiyoda ku Tokyo 102 0082 Japan China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Middle East Extron Middle East Dubai Airport Free Zone F12 PO Box 293666 United Arab Emirates D
18. hed to the bottom of the unit remove them Secure the DVI 110 to the rack shelf using two 4 40 x 3 16 inch screws in opposite diagonal corners Install blank panels or other units on the rack shelf as desired Insert the shelf into the rack aligning the holes in the shelf with those of the rack Secure the shelf to the rack using the supplied machine screws This shelf can be mounted in the front or in the rear of the rack Furniture Mounting To mount the DVI 110 under a desk top podium or other furniture use the optional MBU 125 Under desk Mounting Kit part number 70 077 01 as follows If rubber feet are attached to the bottom of the unit remove them Remove the screws from one side of the DVI 110 Retain the screws for possible later 1 1 2 reassembly Attach one bracket to the side of the unit using the provided machine screws see the illustration at right Repeat steps 2 and 3 on the other side of the DVI 110 Hold the unit with the attached brackets against the underside of the table or other furniture On the mounting surface mark the locations of the bracket screw holes Drill pilot holes 3 32 inch 2 mm in diameter 1 4 inch 6 3 mm deep in the mounting surface at the marked screw locations DVI 110 Reference Information 11 Insert 8 wood screws into the four pilot holes Tighten each screw into the mounting surface until slightly less than 1 4 inch of the screw head protrudes Ali
19. iel doit tre utilis avec une alimentation principale comportant un fil de terre neutre Le troisi me contact de mise la terre constitue un dispositif de s curit n essayez pas de la contourner ni de la d sactiver D connexion de l alimentation Pour mettre le mat riel hors tension sans danger d connectez tous les cordons d alimentation de l arri re de l appareil ou du module d alimentation de bureau s il est amovible ou encore de la prise secteur Protection du cordon d alimentation Acheminer les cordons d alimentation de mani re ce que personne ne risque de marcher dessus et ce qu ils ne soient pas cras s ou pinc s par des objets R paration maintenance Faire ex cuter toutes les interventions de r paration maintenance par un technicien qualifi Aucun des l ments internes ne peut tre r par par l utilisateur Afin d viter tout danger d lectrocution l utilisateur ne doit pas essayer de proc der lui m me ces op rations car l ouverture ou le retrait des couvercles risquent de l exposer de hautes tensions et autres dangers Fentes et orifices Si le bo tier de l appareil comporte des fentes ou des orifices ceux ci servent emp cher les composants internes sensibles de surchauffer Ces ouvertures ne doivent jamais tre bloqu es par des objets Lithium Batterie e a danger d explosion s ll y a remplacment incorrect de la batterie Remplacer uniquement avec une batterie du meme type ou d
20. nt should be operated only from the power source indicated on the product This equipment is intended to be used with a main power system with a grounded neutral conductor The third grounding pin is a safety feature do not attempt to bypass or disable it Power disconnection To remove power from the equipment safely remove all power cords from the rear of the equipment or the desktop power module if detachable or from the power source receptacle wall plug Power cord protection Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them Servicing Refer all servicing to qualified service personnel There are no user serviceable parts inside To prevent the risk of shock do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards Slots and openings If the equipment has slots or holes in the enclosure these are provided to prevent overheating of sensitive components inside These openings must never be blocked by other objects Lithium battery There is a danger of explosion if battery is incorrectly replaced Replace it only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Avertissement Alimentations Ne faire fonctionner ce mat riel qu avec la source d alimentation indiqu e sur l appareil Ce mat r
21. stallation This section describes the features of the DVI 110 front and rear panels and provides instructions for cabling It covers the following topics e Front and Rear Panel Features and Connections e Connecting the DVI 110 Front and Rear Panel Features and Connections Extron DVI D O JTPUT xt HEE Jo POWER DVI D I IPUT 12V DVI 110 Figure 4 DVI 110 Front and Rear Panels Power and signal status LED This dual color LED lights amber when the DVI 110 is receiving power When a DVI input signal is present the LED lights green NOTE Use the provided external power supply to power the unit The DVI 110 cannot receive power from the input device pvi D output connector Plug the cable from this single link format DVI I connector into a DVI output device Output signals are digital only See the pin assignment table on the next page NOTES For the output use cables that are 15 feet 4 5 m or less e Although this is actually a DVI I connector its analog pins are not enabled Only DVI D signals are accepted DVI 110 e Installation 4 1 8 9 17 24 Female Connector Signal TMDS data 2 TMDS data 1 TMDS data 0 TMDS data 2 TMDS data 1 TMDS data 0 TMDS data 2 shield TMDS data 1 shield TMDS data 0 shield Spare Spare Spare Spare Spare Spare DDC clock 5 V power TMDS clo
22. tly fix the power supply to the building structure or similar structures Do not place the power supply within environmental air handling spaces or the wall cavity The installation must be in accordance with the applicable provisions of the National Electrical Code ANSI NFPA 70 Article 725 and the Canadian Electrical Code Part 1 Section 16 The power supply must be located within the same vicinity as the Extron A V processing equipment in an ordinary location Pollution Degree 2 and secured to a podium a desk or an equipment rack within a dedicated closet Always use a power supply specified by Extron for the DVI 110 Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the power supply and the unit Connecting the DVI 110 For best results connect the DVI 110 near the DVI source device in the system The input and output cables to and from the DVI 110 should be 15 feet 4 5 m or less To ensure transmission integrity in a long cable run place an Extron DVI 101 cable equalizer at the end of the run immediately preceding the output device DVI 110 e Installation 6 Reference Information This section reference information for the DVI 110 signal regenerator Topics that are covered include e Specifications e Part Numbers e Mounting the DVI 110 Specifications NOTE Appropriate DVI D to HDMI cables or adapters are required for HDMI signal input and output
23. ubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were not authorized by Extron If a product is defective please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This begins the repair process 31 33 453 4040 81 3 3511 7655 USA 714 491 1500 Asia 65 6383 4400 Europe Japan Units must be returned insured with shipping charges prepaid If not insured you assume the risk of loss or damage during shipment Returned units must include the serial number and a description of the problem as well as the name of the person to contact in case there are any questions Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality performance merchantability or fitness for any particular use In no event will Extron Electronics be liable for direct indirect or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage Please note that laws vary from state to state and country to country and that some provisions of this warranty may not apply to you Extron USA West Headquarters 800 633 9876 Extron USA East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East 81 3 35

Download Pdf Manuals

image

Related Search

Related Contents

HANNA HI 93705 Silica ISM Instruction Manual              ASRock GE Pro-HT GE Pro-M2 User Manual      

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.